{"id":"https://openalex.org/W2905148101","doi":"https://doi.org/10.1109/isgteurope.2018.8571812","title":"The Impact of Point-To-Point VSC-HVDC Protection on Short-Term AC System Voltage","display_name":"The Impact of Point-To-Point VSC-HVDC Protection on Short-Term AC System Voltage","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2905148101","doi":"https://doi.org/10.1109/isgteurope.2018.8571812","mag":"2905148101"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2018.8571812","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2018.8571812","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051990924","display_name":"Geraint Chaffey","orcid":"https://orcid.org/0000-0002-2947-1100"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Geraint Chaffey","raw_affiliation_strings":["KU Leuven and EnergyVille, Leuven, Belgium and Genk, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KU Leuven and EnergyVille, Leuven, Belgium and Genk, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018842792","display_name":"Dirk Van Hertem","orcid":"https://orcid.org/0000-0001-5461-8891"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Dirk Van Hertem","raw_affiliation_strings":["KU Leuven and EnergyVille, Leuven, Belgium and Genk, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KU Leuven and EnergyVille, Leuven, Belgium and Genk, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034511631","display_name":"Niklas Svensson","orcid":null},"institutions":[{"id":"https://openalex.org/I4405269927","display_name":"Svenska kraftn\u00e4t","ror":"https://ror.org/05ncf3202","country_code":"SE","type":"government","lineage":["https://openalex.org/I4405269927"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Niklas Svensson","raw_affiliation_strings":["Svenska Kraftn\u00e4t, Sundbyberg, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Svenska Kraftn\u00e4t, Sundbyberg, Sweden","institution_ids":["https://openalex.org/I4405269927"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036183004","display_name":"Staffan Norrga","orcid":"https://orcid.org/0000-0002-8565-4753"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Staffan Norrga","raw_affiliation_strings":["SCiBreak AB, Stockholm, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SCiBreak AB, Stockholm, Sweden","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076995673","display_name":"Lennart \u00c4ngquist","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Lennart Angquist","raw_affiliation_strings":["SCiBreak AB, Stockholm, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SCiBreak AB, Stockholm, Sweden","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9911999702453613,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9763000011444092,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.8109902143478394},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.693266749382019},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.6298715472221375},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6261491775512695},{"id":"https://openalex.org/keywords/hvdc-converter-station","display_name":"HVDC converter station","score":0.611785888671875},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5320824980735779},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5194451212882996},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.48048344254493713},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.44768452644348145},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.44597649574279785},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.42711713910102844},{"id":"https://openalex.org/keywords/point","display_name":"Point (geometry)","score":0.42109400033950806},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3718937337398529},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1042991578578949},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.06490150094032288}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.8109902143478394},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.693266749382019},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6298715472221375},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6261491775512695},{"id":"https://openalex.org/C7904685","wikidata":"https://www.wikidata.org/wiki/Q2356943","display_name":"HVDC converter station","level":3,"score":0.611785888671875},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5320824980735779},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5194451212882996},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48048344254493713},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44768452644348145},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.44597649574279785},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42711713910102844},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.42109400033950806},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3718937337398529},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1042991578578949},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.06490150094032288},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2018.8571812","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2018.8571812","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.6299999952316284,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1953557166","https://openalex.org/W2083708803","https://openalex.org/W2533151055","https://openalex.org/W2547603851","https://openalex.org/W2589750523","https://openalex.org/W2594836072","https://openalex.org/W2614206397","https://openalex.org/W2742461864"],"related_works":["https://openalex.org/W2186957643","https://openalex.org/W4313289174","https://openalex.org/W2169296235","https://openalex.org/W631083485","https://openalex.org/W2383147444","https://openalex.org/W2772771794","https://openalex.org/W2370462073","https://openalex.org/W2351129194","https://openalex.org/W2369017828","https://openalex.org/W4313452936"],"abstract_inverted_index":{"Whilst":[0],"point-to-point":[1],"HVDC":[2,42,64],"systems":[3],"are":[4,21],"presently":[5],"protected":[6],"from":[7],"DC-side":[8,72],"faults":[9],"using":[10,68],"circuit":[11,38],"breakers":[12,39],"at":[13],"the":[14,17,29,33,41,50,58,76,83],"AC-side":[15],"of":[16,54,78],"converter":[18],"stations,":[19],"converters":[20],"unable":[22],"to":[23,28,57],"provide":[24],"reactive":[25,55],"power":[26,56,92],"support":[27],"AC":[30,59,84],"system":[31,43,65],"during":[32],"fault":[34],"clearance.":[35],"Implementing":[36],"DC":[37],"within":[40],"could":[44],"result":[45],"in":[46],"several":[47],"benefits,":[48],"including":[49],"near-":[51],"continuous":[52],"provision":[53],"systems.":[60],"This":[61],"paper":[62],"compares":[63],"protection":[66,80],"sequences":[67],"AC-":[69],"side":[70],"and":[71,74,90],"protection,":[73],"evaluates":[75],"impact":[77],"these":[79],"strategies":[81],"on":[82],"voltage":[85],"under":[86],"varying":[87,91],"AC-system":[88],"configurations":[89],"flow":[93],"conditions.":[94]},"counts_by_year":[{"year":2021,"cited_by_count":2}],"updated_date":"2026-07-25T15:57:00.446498","created_date":"2025-10-10T00:00:00"}
