{"id":"https://openalex.org/W2783712017","doi":"https://doi.org/10.1109/isgteurope.2017.8260282","title":"On the design and placement of a supplementary damping controller in an embedded VSC-MTDC network","display_name":"On the design and placement of a supplementary damping controller in an embedded VSC-MTDC network","publication_year":2017,"publication_date":"2017-09-01","ids":{"openalex":"https://openalex.org/W2783712017","doi":"https://doi.org/10.1109/isgteurope.2017.8260282","mag":"2783712017"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2017.8260282","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2017.8260282","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5030474810","display_name":"Omar Kotb","orcid":"https://orcid.org/0000-0002-6263-8638"},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":true,"raw_author_name":"Omar Kotb","raw_affiliation_strings":["Dept. of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden"],"affiliations":[{"raw_affiliation_string":"Dept. of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070409366","display_name":"Mehrdad Ghandhari","orcid":null},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Mehrdad Ghandhari","raw_affiliation_strings":["Dept. of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden"],"affiliations":[{"raw_affiliation_string":"Dept. of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030608595","display_name":"Javier Renedo","orcid":"https://orcid.org/0000-0002-1740-8729"},"institutions":[{"id":"https://openalex.org/I96580804","display_name":"Comillas Pontifical University","ror":"https://ror.org/017mdc710","country_code":"ES","type":"education","lineage":["https://openalex.org/I96580804"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Javier Renedo","raw_affiliation_strings":["IIT Institute for Research in Technology, Comillas Pontifical University, Madrid, Spain"],"affiliations":[{"raw_affiliation_string":"IIT Institute for Research in Technology, Comillas Pontifical University, Madrid, Spain","institution_ids":["https://openalex.org/I96580804"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027448328","display_name":"Luis Rouco","orcid":"https://orcid.org/0000-0002-2670-7464"},"institutions":[{"id":"https://openalex.org/I96580804","display_name":"Comillas Pontifical University","ror":"https://ror.org/017mdc710","country_code":"ES","type":"education","lineage":["https://openalex.org/I96580804"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Luis Rouco","raw_affiliation_strings":["IIT Institute for Research in Technology, Comillas Pontifical University, Madrid, Spain"],"affiliations":[{"raw_affiliation_string":"IIT Institute for Research in Technology, Comillas Pontifical University, Madrid, Spain","institution_ids":["https://openalex.org/I96580804"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091703695","display_name":"Robert Eriksson","orcid":"https://orcid.org/0000-0002-2356-4795"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Robert Eriksson","raw_affiliation_strings":["Swedish National Grid, Svenska Kraftn\u00e4t, Sundbyberg, Sweden"],"affiliations":[{"raw_affiliation_string":"Swedish National Grid, Svenska Kraftn\u00e4t, Sundbyberg, Sweden","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5030474810"],"corresponding_institution_ids":["https://openalex.org/I86987016"],"apc_list":null,"apc_paid":null,"fwci":0.43,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.67108009,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"28","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.8164128065109253},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5784491300582886},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5037235617637634},{"id":"https://openalex.org/keywords/full-state-feedback","display_name":"Full state feedback","score":0.43362611532211304},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.41771864891052246},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.391970157623291},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3716881275177002},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2458365559577942},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.13042950630187988},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10901913046836853}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.8164128065109253},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5784491300582886},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5037235617637634},{"id":"https://openalex.org/C204322392","wikidata":"https://www.wikidata.org/wiki/Q925922","display_name":"Full state feedback","level":3,"score":0.43362611532211304},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41771864891052246},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.391970157623291},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3716881275177002},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2458365559577942},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.13042950630187988},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10901913046836853},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2017.8260282","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2017.8260282","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.6200000047683716,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W609889076","https://openalex.org/W771565117","https://openalex.org/W1763243278","https://openalex.org/W1978982778","https://openalex.org/W1990810020","https://openalex.org/W1993021610","https://openalex.org/W2013510155","https://openalex.org/W2034978548","https://openalex.org/W2090638101","https://openalex.org/W2094086554","https://openalex.org/W2106544784","https://openalex.org/W2108066623","https://openalex.org/W2125507862","https://openalex.org/W2126721443","https://openalex.org/W2145202743","https://openalex.org/W2160160418","https://openalex.org/W2286052986","https://openalex.org/W2310008994","https://openalex.org/W2536194216","https://openalex.org/W2543945881","https://openalex.org/W3106461780","https://openalex.org/W3216795306"],"related_works":["https://openalex.org/W2624078249","https://openalex.org/W2091723420","https://openalex.org/W1900673034","https://openalex.org/W2535601313","https://openalex.org/W2900382844","https://openalex.org/W2897874637","https://openalex.org/W138095869","https://openalex.org/W1978601421","https://openalex.org/W2058071114","https://openalex.org/W2393509435"],"abstract_inverted_index":{"This":[0],"paper":[1],"investigates":[2],"the":[3,41,49,59,70,72,78,85,94,97,100,122,125,129,132,143,149],"optimal":[4],"placement":[5,42],"and":[6,43],"design":[7,44,98],"of":[8,45,69,74,88,99,124,136,151],"a":[9,36],"Power":[10],"Oscillation":[11],"Damping":[12],"(POD)":[13],"controller":[14,76,102,126],"within":[15,77],"an":[16,27],"embedded":[17],"VSC-MTDC":[18,21],"network.":[19],"As":[20],"networks":[22],"are":[23],"expected":[24],"to":[25,39,54,58,84,127,141],"play":[26],"eminent":[28],"role":[29],"in":[30,48,52,131,134],"interconnecting":[31],"AC":[32,61],"grids,":[33],"there":[34],"is":[35,81,103],"growing":[37],"need":[38],"optimize":[40],"supplementary":[46],"controllers":[47],"MTDC":[50,79],"converters,":[51],"order":[53],"maximize":[55],"their":[56],"benefit":[57],"connected":[60],"systems.":[62],"Based":[63],"on":[64,105],"small":[65,144],"signal":[66,145],"stability":[67,146],"analysis":[68],"system,":[71],"location":[73],"damping":[75,101,130,150],"network":[80],"selected":[82],"according":[83],"eigenvalue":[86],"sensitivity":[87],"poorly":[89],"damped":[90],"oscillatory":[91],"modes.":[92,153],"On":[93],"other":[95],"hand,":[96],"based":[104],"Modal":[106],"Linear":[107],"Quadratic":[108],"Gaussian":[109],"(MLQG)":[110],"control":[111],"that":[112],"uses":[113],"Wide":[114],"Area":[115],"Measurement":[116],"Signals":[117],"(WAMS).":[118],"The":[119],"results":[120],"show":[121],"ability":[123],"enhance":[128],"system":[133],"case":[135],"disturbances,":[137],"as":[138,140],"well":[139],"improve":[142],"by":[147],"boosting":[148],"inter-area":[152]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
