{"id":"https://openalex.org/W2783217257","doi":"https://doi.org/10.1109/isgteurope.2017.8260123","title":"Optimal capacity planning of solar PV inverters for distribution system with reactive-power transaction","display_name":"Optimal capacity planning of solar PV inverters for distribution system with reactive-power transaction","publication_year":2017,"publication_date":"2017-09-01","ids":{"openalex":"https://openalex.org/W2783217257","doi":"https://doi.org/10.1109/isgteurope.2017.8260123","mag":"2783217257"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2017.8260123","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2017.8260123","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019867951","display_name":"Jian\u2010Tang Liao","orcid":"https://orcid.org/0000-0003-1617-8439"},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Jian-Tang Liao","raw_affiliation_strings":["Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049760466","display_name":"Chien-Hsuan Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Chien-Hsuan Liu","raw_affiliation_strings":["Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046413348","display_name":"Hong\u2010Tzer Yang","orcid":"https://orcid.org/0000-0002-1965-0922"},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Hong-Tzer Yang","raw_affiliation_strings":["Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.22876986,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/tap-changer","display_name":"Tap changer","score":0.6846977472305298},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.6817112565040588},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.6245057582855225},{"id":"https://openalex.org/keywords/capacity-optimization","display_name":"Capacity optimization","score":0.5648857355117798},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-power-system","display_name":"Grid-connected photovoltaic power system","score":0.5335873365402222},{"id":"https://openalex.org/keywords/stand-alone-power-system","display_name":"Stand-alone power system","score":0.504165768623352},{"id":"https://openalex.org/keywords/overvoltage","display_name":"Overvoltage","score":0.46864885091781616},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.4586060643196106},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4569036066532135},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.4540293514728546},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4448111057281494},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.43825241923332214},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.433829665184021},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4336109161376953},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.4155331254005432},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.35962963104248047},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.35276663303375244},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.3164757490158081},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3038620948791504},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2857624888420105},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.18793141841888428},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.13044995069503784}],"concepts":[{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.6846977472305298},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6817112565040588},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6245057582855225},{"id":"https://openalex.org/C2776469763","wikidata":"https://www.wikidata.org/wiki/Q5034491","display_name":"Capacity optimization","level":3,"score":0.5648857355117798},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.5335873365402222},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.504165768623352},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.46864885091781616},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.4586060643196106},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4569036066532135},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.4540293514728546},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4448111057281494},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.43825241923332214},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.433829665184021},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4336109161376953},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.4155331254005432},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.35962963104248047},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.35276663303375244},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.3164757490158081},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3038620948791504},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2857624888420105},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.18793141841888428},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.13044995069503784},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2017.8260123","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2017.8260123","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.6499999761581421,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1550724789","https://openalex.org/W1965439834","https://openalex.org/W1970676140","https://openalex.org/W1981160213","https://openalex.org/W1986115814","https://openalex.org/W2027264219","https://openalex.org/W2036896666","https://openalex.org/W2053403930","https://openalex.org/W2069830908","https://openalex.org/W2087279961","https://openalex.org/W2091030660","https://openalex.org/W2091365007","https://openalex.org/W2110144765","https://openalex.org/W2113592937","https://openalex.org/W2166084492","https://openalex.org/W2167996275","https://openalex.org/W2271261135","https://openalex.org/W2334475182","https://openalex.org/W3100081296","https://openalex.org/W4240935130"],"related_works":["https://openalex.org/W3130155859","https://openalex.org/W1974888709","https://openalex.org/W103380046","https://openalex.org/W2542366441","https://openalex.org/W2100189202","https://openalex.org/W2834422676","https://openalex.org/W2326695616","https://openalex.org/W3023079971","https://openalex.org/W2535631659","https://openalex.org/W3190463591"],"abstract_inverted_index":{"Higher":[0],"and":[1,16,29,98,108,129,136,159,182],"higher":[2],"penetration":[3],"of":[4,21,33,62,65,90,101,121,164,179],"photovoltaic":[5],"(PV)":[6],"system":[7,28,35,111,184],"considerably":[8],"affects":[9],"the":[10,18,31,59,70,88,110,119,122,133,150,156,161,165,169,177],"voltage":[11,82,112,130],"in":[12,142],"power":[13,20,26,163],"distribution":[14,27],"systems":[15],"restricts":[17],"feed-in":[19,162],"PV":[22,34,42,102,124,137,166,183],"generation.":[23],"To":[24,117],"stabilize":[25],"increase":[30,160],"profits":[32],"owners,":[36],"this":[37,143],"paper":[38],"proposes":[39],"a":[40,52,80],"dual-loop":[41,72],"smart":[43],"inverter":[44],"(SI)":[45],"capacity":[46,74,126],"optimization":[47,75,127],"method":[48,76,128,152],"which":[49],"collaborates":[50],"with":[51,79],"distribution-level":[53,171],"reactive-power":[54,99,172],"transaction":[55,173],"strategy.":[56,84],"Due":[57],"to":[58,104],"high":[60],"dependency":[61],"optimal":[63],"capacities":[64],"SI":[66,73,103,125],"on":[67],"their":[68],"operations,":[69],"proposed":[71,123,151,170],"is":[77],"integrated":[78],"two-stage":[81],"control":[83,131],"The":[85,145],"strategy":[86,174],"optimizes":[87],"operations":[89],"on-load":[91],"tap":[92],"changer":[93],"(OLTC),":[94],"capacitor":[95],"bank":[96],"(C-bank),":[97],"output":[100],"minimize":[105],"line":[106],"loss":[107],"maintain":[109],"within":[113],"an":[114],"acceptable":[115],"range.":[116],"verify":[118],"feasibility":[120],"strategy,":[132],"practical":[134],"load":[135],"generation":[138],"data":[139],"are":[140],"used":[141],"paper.":[144],"simulation":[146],"results":[147],"show":[148],"that":[149],"can":[153,175],"effectively":[154],"mitigate":[155],"overvoltage":[157],"problems":[158],"system.":[167],"Besides,":[168],"improve":[176],"benefits":[178],"both":[180],"DSO":[181],"owners.":[185]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
