{"id":"https://openalex.org/W2782869405","doi":"https://doi.org/10.1109/isgteurope.2017.8260112","title":"Results of the laboratory tests of a novel regulator for meshed low-voltage networks","display_name":"Results of the laboratory tests of a novel regulator for meshed low-voltage networks","publication_year":2017,"publication_date":"2017-09-01","ids":{"openalex":"https://openalex.org/W2782869405","doi":"https://doi.org/10.1109/isgteurope.2017.8260112","mag":"2782869405"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2017.8260112","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2017.8260112","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108681605","display_name":"Stefan M. Lang","orcid":null},"institutions":[{"id":"https://openalex.org/I153267046","display_name":"University of Kaiserslautern","ror":"https://ror.org/04zrf7b53","country_code":"DE","type":"education","lineage":["https://openalex.org/I153267046"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Stefan Lang","raw_affiliation_strings":["Chair for Energy Systems and Energy Management, Technical University of Kaiserslautern, Kaiserslautern, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chair for Energy Systems and Energy Management, Technical University of Kaiserslautern, Kaiserslautern, Germany","institution_ids":["https://openalex.org/I153267046"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5104076856","display_name":"Haiyan Ma","orcid":null},"institutions":[{"id":"https://openalex.org/I153267046","display_name":"University of Kaiserslautern","ror":"https://ror.org/04zrf7b53","country_code":"DE","type":"education","lineage":["https://openalex.org/I153267046"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Haiyan Ma","raw_affiliation_strings":["Chair for Energy Systems and Energy Management, Technical University of Kaiserslautern, Kaiserslautern, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chair for Energy Systems and Energy Management, Technical University of Kaiserslautern, Kaiserslautern, Germany","institution_ids":["https://openalex.org/I153267046"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062569191","display_name":"Wolfram H. Well\u00dfow","orcid":null},"institutions":[{"id":"https://openalex.org/I153267046","display_name":"University of Kaiserslautern","ror":"https://ror.org/04zrf7b53","country_code":"DE","type":"education","lineage":["https://openalex.org/I153267046"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Wolfram H. Wellssow","raw_affiliation_strings":["Chair for Energy Systems and Energy Management, Technical University of Kaiserslautern, Kaiserslautern, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chair for Energy Systems and Energy Management, Technical University of Kaiserslautern, Kaiserslautern, Germany","institution_ids":["https://openalex.org/I153267046"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I153267046"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.2271496,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12565","display_name":"Physics and Engineering Research Articles","score":0.9839000105857849,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12271","display_name":"Renewable energy and sustainable power systems","score":0.9836000204086304,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.8217727541923523},{"id":"https://openalex.org/keywords/regulator","display_name":"Regulator","score":0.7940715551376343},{"id":"https://openalex.org/keywords/low-dropout-regulator","display_name":"Low-dropout regulator","score":0.7221783399581909},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6731603741645813},{"id":"https://openalex.org/keywords/dropout-voltage","display_name":"Dropout voltage","score":0.5903062224388123},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5445225238800049},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.4737732410430908},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3930642008781433},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.37435615062713623},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3627784848213196},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.32043054699897766},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.29750341176986694},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.24933674931526184},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.11374947428703308},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.07096976041793823}],"concepts":[{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.8217727541923523},{"id":"https://openalex.org/C6929976","wikidata":"https://www.wikidata.org/wiki/Q3771881","display_name":"Regulator","level":3,"score":0.7940715551376343},{"id":"https://openalex.org/C140501009","wikidata":"https://www.wikidata.org/wiki/Q6692746","display_name":"Low-dropout regulator","level":5,"score":0.7221783399581909},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6731603741645813},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.5903062224388123},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5445225238800049},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.4737732410430908},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3930642008781433},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37435615062713623},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3627784848213196},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.32043054699897766},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.29750341176986694},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.24933674931526184},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11374947428703308},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.07096976041793823},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2017.8260112","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2017.8260112","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.75}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2550099288","https://openalex.org/W2564515602","https://openalex.org/W2566839743","https://openalex.org/W6731093580"],"related_works":["https://openalex.org/W1982997428","https://openalex.org/W2991752277","https://openalex.org/W2382804880","https://openalex.org/W2024816799","https://openalex.org/W2476208285","https://openalex.org/W2379548982","https://openalex.org/W2371267182","https://openalex.org/W3185987145","https://openalex.org/W2083807160","https://openalex.org/W2736802678"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,6,25,35,39,68],"results":[4,89],"of":[5,9,72],"laboratory":[7,65],"test":[8],"a":[10,30,42,73],"novel":[11],"voltage":[12,33,82],"and":[13,77,83],"current":[14],"regulator":[15,22,59],"for":[16],"meshed":[17,56],"operated":[18],"low-voltage":[19],"grids.":[20,57],"The":[21,58,88],"can":[23,51],"adjust":[24],"mentioned":[26],"values":[27],"by":[28],"adding":[29],"complex":[31],"control":[32],"to":[34,54],"grid":[36,74],"voltage.":[37],"Besides":[38],"analytical":[40],"basics,":[41],"method":[43],"based":[44],"on":[45],"characteristic":[46],"curves":[47],"is":[48],"explained":[49],"which":[50,70],"be":[52],"applied":[53],"heavily":[55],"has":[60],"been":[61,86],"tested":[62],"in":[63,92],"extensive":[64],"tests.":[66],"In":[67],"laboratory,":[69],"consists":[71],"model,":[75],"loads":[76],"PV-inverters,":[78],"tests":[79],"with":[80],"realistic":[81],"currents":[84],"have":[85],"performed.":[87],"are":[90],"presented":[91],"this":[93],"paper.":[94]},"counts_by_year":[],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}