{"id":"https://openalex.org/W2552970073","doi":"https://doi.org/10.1109/isgteurope.2012.6465823","title":"Experimental implementation of a voltage control for a Multiterminal VSC-HVDC offshore transmission system","display_name":"Experimental implementation of a voltage control for a Multiterminal VSC-HVDC offshore transmission system","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2552970073","doi":"https://doi.org/10.1109/isgteurope.2012.6465823","mag":"2552970073"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465823","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465823","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://hdl.handle.net/2117/20229","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5060292308","display_name":"Agust\u00ed Egea\u2010\u00c0lvarez","orcid":"https://orcid.org/0000-0003-1286-6699"},"institutions":[{"id":"https://openalex.org/I92621186","display_name":"Acciona (Spain)","ror":"https://ror.org/04y85wy15","country_code":"ES","type":"company","lineage":["https://openalex.org/I92621186"]},{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Agusti Egea-Alvarez","raw_affiliation_strings":["Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848","https://openalex.org/I92621186"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060631616","display_name":"Fernando D. Bianchi","orcid":"https://orcid.org/0000-0001-7332-6501"},"institutions":[{"id":"https://openalex.org/I4210128520","display_name":"Institut de Recerca en Energia de Catalunya","ror":"https://ror.org/03b6f4629","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210128520","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Fernando Bianchi","raw_affiliation_strings":["Catalonia Institute of Energy Research, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Catalonia Institute of Energy Research, Barcelona, Spain","institution_ids":["https://openalex.org/I4210128520"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047600558","display_name":"Adri\u00e0 Junyent\u2010Ferr\u00e9","orcid":"https://orcid.org/0000-0002-8500-9906"},"institutions":[{"id":"https://openalex.org/I92621186","display_name":"Acciona (Spain)","ror":"https://ror.org/04y85wy15","country_code":"ES","type":"company","lineage":["https://openalex.org/I92621186"]},{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Adria Junyent-Ferre","raw_affiliation_strings":["Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848","https://openalex.org/I92621186"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110201189","display_name":"G. Gross","orcid":null},"institutions":[{"id":"https://openalex.org/I92621186","display_name":"Acciona (Spain)","ror":"https://ror.org/04y85wy15","country_code":"ES","type":"company","lineage":["https://openalex.org/I92621186"]},{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Gabriel Gross","raw_affiliation_strings":["Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848","https://openalex.org/I92621186"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091210916","display_name":"Oriol Gomis\u2010Bellmunt","orcid":"https://orcid.org/0000-0002-9507-8278"},"institutions":[{"id":"https://openalex.org/I4210128520","display_name":"Institut de Recerca en Energia de Catalunya","ror":"https://ror.org/03b6f4629","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210128520","https://openalex.org/I4387153040"]},{"id":"https://openalex.org/I92621186","display_name":"Acciona (Spain)","ror":"https://ror.org/04y85wy15","country_code":"ES","type":"company","lineage":["https://openalex.org/I92621186"]},{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Oriol Gomis-Bellmunt","raw_affiliation_strings":["Catalonia Institute of Energy Research, Barcelona, Spain","Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Catalonia Institute of Energy Research, Barcelona, Spain","institution_ids":["https://openalex.org/I4210128520"]},{"raw_affiliation_string":"Centre dInnovaci\u00f3 Tecnol\u00f2gica en Convertidors Est\u00e0tics i Accionaments (CITCEA-UPC), Departament dEnginyeria El\u00e8ctrica, ETS dEnginyeria Industrial de Barcelona, Universitat Polit\u00e9cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848","https://openalex.org/I92621186"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.499,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.85051695,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9876000285148621,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.983299970626831,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.8375372290611267},{"id":"https://openalex.org/keywords/offshore-wind-power","display_name":"Offshore wind power","score":0.786430835723877},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5546009540557861},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.5437840223312378},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5385813117027283},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5025246143341064},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.5014998912811279},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4800232946872711},{"id":"https://openalex.org/keywords/disconnection","display_name":"Disconnection","score":0.4732188284397125},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4681793749332428},{"id":"https://openalex.org/keywords/hvdc-converter-station","display_name":"HVDC converter station","score":0.46548357605934143},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.42073577642440796},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.416789710521698},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4154142737388611},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.380935937166214},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.365816593170166},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.3175802230834961},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.07493942975997925}],"concepts":[{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.8375372290611267},{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.786430835723877},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5546009540557861},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.5437840223312378},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5385813117027283},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5025246143341064},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.5014998912811279},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4800232946872711},{"id":"https://openalex.org/C2780371621","wikidata":"https://www.wikidata.org/wiki/Q3709910","display_name":"Disconnection","level":2,"score":0.4732188284397125},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4681793749332428},{"id":"https://openalex.org/C7904685","wikidata":"https://www.wikidata.org/wiki/Q2356943","display_name":"HVDC converter station","level":3,"score":0.46548357605934143},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.42073577642440796},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.416789710521698},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4154142737388611},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.380935937166214},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.365816593170166},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.3175802230834961},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.07493942975997925},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465823","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465823","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:www.recercat.cat:2072/217989","is_oa":true,"landing_page_url":"http://hdl.handle.net/2117/20229","pdf_url":null,"source":{"id":"https://openalex.org/S4306402147","display_name":"RECERCAT (Consorci de Serveis Universitaris de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210090028","host_organization_name":"Consorci de Serveis Universitaris de Catalunya","host_organization_lineage":["https://openalex.org/I4210090028"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:upcommons.upc.edu:2117/20229","is_oa":false,"landing_page_url":"https://hdl.handle.net/2117/20229","pdf_url":null,"source":{"id":"https://openalex.org/S4377196262","display_name":"UPCommons institutional repository (Universitat Polit\u00e8cnica de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I9617848","host_organization_name":"Universitat Polit\u00e8cnica de Catalunya","host_organization_lineage":["https://openalex.org/I9617848"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:www.recercat.cat:2072/217989","is_oa":true,"landing_page_url":"http://hdl.handle.net/2117/20229","pdf_url":null,"source":{"id":"https://openalex.org/S4306402147","display_name":"RECERCAT (Consorci de Serveis Universitaris de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210090028","host_organization_name":"Consorci de Serveis Universitaris de Catalunya","host_organization_lineage":["https://openalex.org/I4210090028"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8500000238418579,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1497285243","https://openalex.org/W1977538532","https://openalex.org/W1993886225","https://openalex.org/W2008162440","https://openalex.org/W2025434244","https://openalex.org/W2033187197","https://openalex.org/W2034978548","https://openalex.org/W2045174480","https://openalex.org/W2061503833","https://openalex.org/W2124881904","https://openalex.org/W2127393635","https://openalex.org/W2127828145","https://openalex.org/W2142923157","https://openalex.org/W2156232631","https://openalex.org/W2160019990","https://openalex.org/W2160957068","https://openalex.org/W2921733795"],"related_works":["https://openalex.org/W4251447409","https://openalex.org/W2357541103","https://openalex.org/W3097649839","https://openalex.org/W2350392996","https://openalex.org/W4363675847","https://openalex.org/W564620664","https://openalex.org/W2368101304","https://openalex.org/W2394451780","https://openalex.org/W2924510155","https://openalex.org/W2885722016"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,34],"design":[4],"and":[5,26,50],"implementation":[6],"of":[7],"a":[8,27],"Multiterminal":[9],"VSC-HVDC":[10],"(Voltage":[11],"Sources":[12],"Converter,":[13],"High":[14],"Voltage":[15],"Direct":[16],"Current)":[17],"experimental":[18,35],"platform.":[19],"Operational":[20],"points":[21],"considering":[22],"offshore":[23],"wind":[24,51],"farms":[25],"droop-based":[28],"controller":[29],"are":[30],"described.":[31],"In":[32],"addition,":[33],"platform":[36],"has":[37],"been":[38],"tested":[39],"under":[40],"several":[41],"conditions":[42],"as:":[43],"normal":[44],"operation,":[45],"grid":[46],"side":[47],"converter":[48,53],"disconnection":[49],"farm":[52],"disconnection.":[54]},"counts_by_year":[{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":5}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
