{"id":"https://openalex.org/W2549298315","doi":"https://doi.org/10.1109/isgteurope.2012.6465805","title":"Effect of Demand Response on transformer lifetime expectation","display_name":"Effect of Demand Response on transformer lifetime expectation","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2549298315","doi":"https://doi.org/10.1109/isgteurope.2012.6465805","mag":"2549298315"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465805","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465805","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043634792","display_name":"Johannes Jargstorf","orcid":null},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Johannes Jargstorf","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054240167","display_name":"Koen Vanthournout","orcid":"https://orcid.org/0000-0002-0139-6591"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Koen Vanthournout","raw_affiliation_strings":["Energy Department of the Research Instituteenergy Department of the Research Institute, VITO, Mol, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Department of the Research Instituteenergy Department of the Research Institute, VITO, Mol, Belgium","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040153857","display_name":"Tom De Rybel","orcid":"https://orcid.org/0000-0001-9051-8070"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Tom De Rybel","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018842792","display_name":"Dirk Van Hertem","orcid":"https://orcid.org/0000-0001-5461-8891"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Dirk Van Hertem","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":29,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9950000047683716,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.8573803901672363},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6858886480331421},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5117661952972412},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.5004892349243164},{"id":"https://openalex.org/keywords/response-time","display_name":"Response time","score":0.44771212339401245},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.44019615650177},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4249868392944336},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3875090181827545},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3671187162399292},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3136318325996399},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27298063039779663},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.27143555879592896},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.2591140866279602},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.09903883934020996}],"concepts":[{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.8573803901672363},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6858886480331421},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5117661952972412},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.5004892349243164},{"id":"https://openalex.org/C19012869","wikidata":"https://www.wikidata.org/wiki/Q578372","display_name":"Response time","level":2,"score":0.44771212339401245},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.44019615650177},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4249868392944336},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3875090181827545},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3671187162399292},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3136318325996399},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27298063039779663},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.27143555879592896},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.2591140866279602},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09903883934020996},{"id":"https://openalex.org/C121684516","wikidata":"https://www.wikidata.org/wiki/Q7600677","display_name":"Computer graphics (images)","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465805","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465805","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:lirias2repo.kuleuven.be:123456789/361257","is_oa":false,"landing_page_url":"https://lirias.kuleuven.be/bitstream/123456789/361257/1/Manuscript_Jargstorf.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S7407055369","display_name":"Lirias","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE PES ISGT Europe 2012, Berlin, 14-17 October 2012","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8399999737739563,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1981670580","https://openalex.org/W2034592449","https://openalex.org/W2037799258","https://openalex.org/W2038872716","https://openalex.org/W2043282011","https://openalex.org/W2076522182","https://openalex.org/W2102734466","https://openalex.org/W2103603046","https://openalex.org/W2107499818","https://openalex.org/W2129589829","https://openalex.org/W2135811075","https://openalex.org/W2158529944","https://openalex.org/W2182510773","https://openalex.org/W2310747195","https://openalex.org/W2536620281","https://openalex.org/W4231996826","https://openalex.org/W4241940087","https://openalex.org/W4256530416","https://openalex.org/W6659843147","https://openalex.org/W6698321475"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2376932109","https://openalex.org/W2390279801","https://openalex.org/W2358668433","https://openalex.org/W1596801655","https://openalex.org/W2387147530","https://openalex.org/W2978432747","https://openalex.org/W3157910026","https://openalex.org/W3096399879"],"abstract_inverted_index":{"Demand":[0,20,44,101,125,161],"Response":[1,21,162],"is":[2,23,31,84,90,104,140,173],"seen":[3],"as":[4],"important":[5],"to":[6,32,56,92,211,225,247],"support":[7],"the":[8,14,26,34,69,78,94,98,109,135,158,164,169,178,184,193,230,233],"integration":[9],"of":[10,39,42,73,80,100,111,114,160,195,209,251],"renewable":[11],"energies":[12],"into":[13],"grid.":[15],"In":[16,46,127],"Flanders,":[17],"a":[18,58,81,112,144,149,227,252],"residential":[19,43],"setup":[22,221,231],"realized":[24],"in":[25,68,207,232],"Linear":[27,234],"pilot.":[28,70],"The":[29,71,138,220],"aim":[30],"assess":[33,157],"potential":[35,249],"benefits":[36],"and":[37,116,192],"ways":[38],"technical":[40],"realization":[41],"Response.":[45,126],"this":[47,128,202],"paper,":[48,129],"household":[49,189,196],"devices,":[50],"like":[51],"washing":[52],"machines,":[53],"are":[54,62,66,131,198],"used":[55,67,91,224,246],"offer":[57],"flexible":[59,75],"load.":[60,219],"These":[61],"also":[63,245],"devices":[64,130,197],"which":[65,236],"effect":[72,99,159],"using":[74,143],"loads":[76],"on":[77,108,119,134,148,163],"lifetime":[79],"low-voltage":[82],"transformer":[83,88,136,165],"assessed.":[85],"An":[86],"IEEE":[87],"model":[89,146],"calculate":[93,97,226],"lifetime.":[95],"To":[96,156,182],"Response,":[102],"aging":[103,167,176,208],"first":[105],"calculated":[106],"based":[107,118,133,147],"load":[110,121,171,180,190],"group":[113],"customers":[115],"then":[117],"their":[120],"being":[122],"optimized":[123,141],"by":[124,142],"scheduled":[132],"temperature.":[137],"temperature":[139],"simulation":[145],"mixed":[150],"integer":[151],"quadratic":[152],"programming":[153],"(MIQP)":[154],"scheduler.":[155,241],"lifetime,":[166],"for":[168,177,188,201,214,229],"improved":[170],"curve":[172],"compared":[174],"with":[175],"initial":[179],"curve.":[181],"demonstrate":[183],"impact,":[185],"realistic":[186],"data":[187,204],"curves":[191],"usage":[194],"employed.":[199],"Results":[200],"input":[203],"show":[205],"reductions":[206],"up":[210],"75":[212],"%":[213],"transformers":[215],"operating":[216],"at":[217],"rated":[218],"will":[222,237,243],"be":[223,244],"benchmark":[228],"pilot,":[235],"use":[238],"an":[239],"on-line":[240],"It":[242],"determine":[248],"outcome":[250],"business":[253],"case.":[254]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":7},{"year":2014,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}