{"id":"https://openalex.org/W2549932969","doi":"https://doi.org/10.1109/isgteurope.2012.6465720","title":"Assessing the risk associated with a high penetration of System Integrity Protection Schemes","display_name":"Assessing the risk associated with a high penetration of System Integrity Protection Schemes","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2549932969","doi":"https://doi.org/10.1109/isgteurope.2012.6465720","mag":"2549932969"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465720","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465720","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000693009","display_name":"Mathaios Panteli","orcid":"https://orcid.org/0000-0003-4274-529X"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"M. Panteli","raw_affiliation_strings":["University of Manchester, Manchester, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Manchester, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5113592506","display_name":"P.A. Crossley","orcid":"https://orcid.org/0000-0002-8986-0677"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"P. A. Crossley","raw_affiliation_strings":["University of Manchester, Manchester, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Manchester, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5685,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.79693958,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6802941560745239},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6712167859077454},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5494493842124939},{"id":"https://openalex.org/keywords/system-integrity","display_name":"System integrity","score":0.5348469614982605},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5134707093238831},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.46482589840888977},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.4436691701412201},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3214009404182434},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2923833429813385},{"id":"https://openalex.org/keywords/business","display_name":"Business","score":0.10818463563919067}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6802941560745239},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6712167859077454},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5494493842124939},{"id":"https://openalex.org/C2777499013","wikidata":"https://www.wikidata.org/wiki/Q7663719","display_name":"System integrity","level":2,"score":0.5348469614982605},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5134707093238831},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.46482589840888977},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.4436691701412201},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3214009404182434},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2923833429813385},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.10818463563919067},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465720","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465720","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:openaire_cris_publications/1710d776-b88c-4661-8916-e5a93fa96799","is_oa":false,"landing_page_url":"https://research.manchester.ac.uk/en/publications/1710d776-b88c-4661-8916-e5a93fa96799","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Panteli, M & Crossley, P A 2012, Assessing the risk associated with a high penetration of system integrity protection schemes. in 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe, ISGT Europe 2012., 6465720, 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe, ISGT Europe 2012, Berlin, Germany, 14/10/12. https://doi.org/10.1109/ISGTEurope.2012.6465720","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:pure.atira.dk:publications/1710d776-b88c-4661-8916-e5a93fa96799","is_oa":false,"landing_page_url":"https://www.research.manchester.ac.uk/portal/en/publications/assessing-the-risk-associated-with-a-high-penetration-of-system-integrity-protection-schemes(1710d776-b88c-4661-8916-e5a93fa96799).html","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Panteli, M & Crossley, P A 2012, Assessing the risk associated with a high penetration of system integrity protection schemes. in 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe, ISGT Europe 2012., 6465720, 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe, ISGT Europe 2012, Berlin, Germany, 14/10/12. https://doi.org/10.1109/ISGTEurope.2012.6465720","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8299999833106995,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1995244334","https://openalex.org/W2050438894","https://openalex.org/W2117397926","https://openalex.org/W2123007178","https://openalex.org/W2150970209","https://openalex.org/W2155891432","https://openalex.org/W2397161921","https://openalex.org/W2542515991","https://openalex.org/W6712443729"],"related_works":["https://openalex.org/W2033512842","https://openalex.org/W4322734194","https://openalex.org/W1607054433","https://openalex.org/W3005535424","https://openalex.org/W4233600955","https://openalex.org/W2913665393","https://openalex.org/W2994319598","https://openalex.org/W2155742919","https://openalex.org/W2139883237","https://openalex.org/W2171781874"],"abstract_inverted_index":{"System":[0],"Integrity":[1],"Protection":[2],"Schemes":[3],"(SIPS)":[4],"are":[5,129],"a":[6,68,113,121],"widely":[7],"used":[8,97,130],"solution":[9],"to":[10,21,98,131],"the":[11,22,45,60,72,76,82,100,106,118],"problems":[12],"in":[13,35],"operating":[14],"increasingly":[15],"stressed":[16],"power":[17,55,115],"systems.":[18],"This":[19,65,108],"leads":[20],"application":[23],"of":[24,27,39,62,89,92,102,120],"large":[25],"numbers":[26],"SIPS":[28,80,95,128],"on":[29,81],"many":[30],"national":[31],"networks,":[32],"which":[33],"results":[34],"an":[36,103],"increased":[37],"probability":[38,61,88,101],"undesirable":[40],"and":[41,58,127],"unplanned":[42],"interactions":[43],"amongst":[44],"SIPS.":[46,107],"Recent":[47],"electrical":[48],"disturbances":[49],"evidenced":[50],"that":[51],"these":[52],"events":[53],"decrease":[54],"system":[56,125,134],"reliability":[57],"increase":[59],"widespread":[63],"incidents.":[64],"paper":[66],"proposes":[67],"procedure":[69],"for":[70],"assessing":[71],"risk":[73],"caused":[74],"by":[75],"interaction":[77,104],"between":[78,105],"different":[79],"same":[83],"or":[84],"neighbouring":[85],"networks.":[86],"The":[87],"adverse":[90],"operation":[91],"each":[93],"individual":[94],"is":[96,110],"evaluate":[99],"method":[109],"illustrated":[111],"using":[112],"small":[114],"system,":[116],"where":[117],"installation":[119],"wind":[122],"park":[123],"increases":[124],"stress":[126],"ensure":[132],"stable":[133],"operation.":[135]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
