{"id":"https://openalex.org/W2550914594","doi":"https://doi.org/10.1109/isgteurope.2012.6465656","title":"A case study of coordinated electric vehicle charging for peak shaving on a low voltage grid","display_name":"A case study of coordinated electric vehicle charging for peak shaving on a low voltage grid","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2550914594","doi":"https://doi.org/10.1109/isgteurope.2012.6465656","mag":"2550914594"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465656","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465656","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://lirias.kuleuven.be/handle/123456789/367125","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090844548","display_name":"Niels Leemput","orcid":null},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"N. Leemput","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108478659","display_name":"Frederik Geth","orcid":null},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"F. Geth","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078508556","display_name":"Bert Claessens","orcid":"https://orcid.org/0009-0006-6116-1483"},"institutions":[{"id":"https://openalex.org/I68522396","display_name":"Flemish Institute for Technological Research","ror":"https://ror.org/04gq0w522","country_code":"BE","type":"facility","lineage":["https://openalex.org/I68522396"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"B. Claessens","raw_affiliation_strings":["VITO, Mol, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"VITO, Mol, Belgium","institution_ids":["https://openalex.org/I68522396"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057803344","display_name":"Juan Van Roy","orcid":null},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"J. Van Roy","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003493181","display_name":"Raf Ponnette","orcid":null},"institutions":[{"id":"https://openalex.org/I68522396","display_name":"Flemish Institute for Technological Research","ror":"https://ror.org/04gq0w522","country_code":"BE","type":"facility","lineage":["https://openalex.org/I68522396"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"R. Ponnette","raw_affiliation_strings":["VITO, Mol, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"VITO, Mol, Belgium","institution_ids":["https://openalex.org/I68522396"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027002529","display_name":"Johan Driesen","orcid":"https://orcid.org/0000-0002-1025-0949"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"J. Driesen","raw_affiliation_strings":["Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT), Division ELECTA, KU Leuven, Leuven-Heverlee, Belgium","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":51,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.996399998664856,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/peaking-power-plant","display_name":"Peaking power plant","score":0.757917046546936},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.7090317010879517},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6991816163063049},{"id":"https://openalex.org/keywords/electric-vehicle","display_name":"Electric vehicle","score":0.5487242937088013},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5033583045005798},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4867403507232666},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.46614351868629456},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4506067931652069},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43838319182395935},{"id":"https://openalex.org/keywords/peak-demand","display_name":"Peak demand","score":0.43052423000335693},{"id":"https://openalex.org/keywords/power-flow","display_name":"Power flow","score":0.4244702458381653},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.4162830412387848},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3708513379096985},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3396633267402649},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.27159589529037476},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2382904291152954},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.15458127856254578},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10434511303901672},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07754570245742798},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.07254859805107117}],"concepts":[{"id":"https://openalex.org/C154594046","wikidata":"https://www.wikidata.org/wiki/Q18979989","display_name":"Peaking power plant","level":4,"score":0.757917046546936},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.7090317010879517},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6991816163063049},{"id":"https://openalex.org/C2776422217","wikidata":"https://www.wikidata.org/wiki/Q13629441","display_name":"Electric vehicle","level":3,"score":0.5487242937088013},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5033583045005798},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4867403507232666},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.46614351868629456},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4506067931652069},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43838319182395935},{"id":"https://openalex.org/C147940328","wikidata":"https://www.wikidata.org/wiki/Q3393666","display_name":"Peak demand","level":3,"score":0.43052423000335693},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.4244702458381653},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.4162830412387848},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3708513379096985},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3396633267402649},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.27159589529037476},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2382904291152954},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.15458127856254578},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10434511303901672},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07754570245742798},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.07254859805107117},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465656","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465656","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:lirias2repo.kuleuven.be:123456789/367125","is_oa":true,"landing_page_url":"https://lirias.kuleuven.be/handle/123456789/367125","pdf_url":null,"source":{"id":"https://openalex.org/S7407055369","display_name":"Lirias","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"IEEE PES Innovative Smart Grid Technologies Europe, Berlin, Germany, 14-17 October 2012","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:lirias2repo.kuleuven.be:123456789/367125","is_oa":true,"landing_page_url":"https://lirias.kuleuven.be/handle/123456789/367125","pdf_url":null,"source":{"id":"https://openalex.org/S7407055369","display_name":"Lirias","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"IEEE PES Innovative Smart Grid Technologies Europe, Berlin, Germany, 14-17 October 2012","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1863349","https://openalex.org/W82275334","https://openalex.org/W1604973446","https://openalex.org/W1963911185","https://openalex.org/W1969739127","https://openalex.org/W2009722708","https://openalex.org/W2049814057","https://openalex.org/W2068317622","https://openalex.org/W2071267648","https://openalex.org/W2071720978","https://openalex.org/W2090252184","https://openalex.org/W2143500594","https://openalex.org/W2144064425","https://openalex.org/W2165105105","https://openalex.org/W2310747195","https://openalex.org/W2338327374","https://openalex.org/W2523711065","https://openalex.org/W2803920774","https://openalex.org/W3132226506","https://openalex.org/W6600075290","https://openalex.org/W6603335459","https://openalex.org/W6698321475"],"related_works":["https://openalex.org/W2012015410","https://openalex.org/W2773970703","https://openalex.org/W4385544394","https://openalex.org/W2898893456","https://openalex.org/W2792195477","https://openalex.org/W3040620667","https://openalex.org/W3007928289","https://openalex.org/W4389671033","https://openalex.org/W10626332","https://openalex.org/W2172084342"],"abstract_inverted_index":{"This":[0],"paper":[1],"discusses":[2],"the":[3,37,40,60,63,78,90],"impact":[4,61,72],"of":[5,8,73,102],"coordinated":[6,31,74],"charging":[7,32,75],"electric":[9],"vehicles":[10],"for":[11,28,76,83],"a":[12,53,70,99],"peak":[13,41,79],"shaving":[14,80],"objective,":[15],"through":[16],"an":[17,45],"online":[18],"coordination":[19,91],"algorithm,":[20],"on":[21,39,52,62],"low":[22,55],"voltage":[23,56,84],"grid":[24,57],"constraints.":[25],"The":[26,66,86],"results":[27,68,87],"uncoordinated":[29],"and":[30,82,105],"are":[33],"compared":[34],"to":[35,58],"assess":[36,59],"effect":[38],"power":[42],"demand.":[43],"Furthermore,":[44],"unbalanced":[46],"load":[47],"flow":[48],"analysis":[49],"is":[50],"performed":[51],"real":[54],"nodal":[64],"voltages.":[65],"simulation":[67],"show":[69,88],"positive":[71],"both":[77],"objective":[81],"deviations.":[85],"that":[89],"algorithm":[92],"obtains":[93],"effective":[94],"results,":[95],"while":[96],"only":[97],"needing":[98],"limited":[100],"amount":[101],"communication,":[103],"measurements":[104],"predictive":[106],"knowledge.":[107]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":3},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":7},{"year":2015,"cited_by_count":7},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":6},{"year":2012,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
