{"id":"https://openalex.org/W2070784867","doi":"https://doi.org/10.1109/isgteurope.2012.6465637","title":"Distributed control strategy for a grid-connected hybrid system with batteries and renewable sources","display_name":"Distributed control strategy for a grid-connected hybrid system with batteries and renewable sources","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2070784867","doi":"https://doi.org/10.1109/isgteurope.2012.6465637","mag":"2070784867"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465637","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465637","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5097991536","display_name":"Oana L. Onet","orcid":null},"institutions":[{"id":"https://openalex.org/I158333966","display_name":"Technical University of Cluj-Napoca","ror":"https://ror.org/03r8nwp71","country_code":"RO","type":"education","lineage":["https://openalex.org/I158333966"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Oana L. Onet","raw_affiliation_strings":["Electric Power System Department, Technical University of Cluj-Napoca, Cluj, Romania","Electr. Power Syst. Dept., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power System Department, Technical University of Cluj-Napoca, Cluj, Romania","institution_ids":["https://openalex.org/I158333966"]},{"raw_affiliation_string":"Electr. Power Syst. Dept., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania","institution_ids":["https://openalex.org/I158333966"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031571639","display_name":"Damien Paire","orcid":"https://orcid.org/0000-0003-4133-9265"},"institutions":[{"id":"https://openalex.org/I37553959","display_name":"Universit\u00e9 de technologie de belfort-montb\u00e9liard","ror":"https://ror.org/05bn3m307","country_code":"FR","type":"education","lineage":["https://openalex.org/I37553959"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Damien Paire","raw_affiliation_strings":["Institut de Recherche sur les Transports, l'Energie et la Societe (IRTES-SeT), Universite de Technologie de Belfort-Montbeliard, Belfort, France","Inst. de Rech. sur les Transp., l'Energie et la Soc. (IRTES-SeT), Univ. de Technol. de Belfort Montbeliard (UTBM), Belfort, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut de Recherche sur les Transports, l'Energie et la Societe (IRTES-SeT), Universite de Technologie de Belfort-Montbeliard, Belfort, France","institution_ids":["https://openalex.org/I37553959"]},{"raw_affiliation_string":"Inst. de Rech. sur les Transp., l'Energie et la Soc. (IRTES-SeT), Univ. de Technol. de Belfort Montbeliard (UTBM), Belfort, France","institution_ids":["https://openalex.org/I37553959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048890166","display_name":"Arnaud Gaillard","orcid":"https://orcid.org/0000-0001-6687-8770"},"institutions":[{"id":"https://openalex.org/I37553959","display_name":"Universit\u00e9 de technologie de belfort-montb\u00e9liard","ror":"https://ror.org/05bn3m307","country_code":"FR","type":"education","lineage":["https://openalex.org/I37553959"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Arnaud Gaillard","raw_affiliation_strings":["Institut de Recherche sur les Transports, l'Energie et la Societe (IRTES-SeT), Universite de Technologie de Belfort-Montbeliard, Belfort, France","Inst. de Rech. sur les Transp., l'Energie et la Soc. (IRTES-SeT), Univ. de Technol. de Belfort Montbeliard (UTBM), Belfort, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut de Recherche sur les Transports, l'Energie et la Societe (IRTES-SeT), Universite de Technologie de Belfort-Montbeliard, Belfort, France","institution_ids":["https://openalex.org/I37553959"]},{"raw_affiliation_string":"Inst. de Rech. sur les Transp., l'Energie et la Soc. (IRTES-SeT), Univ. de Technol. de Belfort Montbeliard (UTBM), Belfort, France","institution_ids":["https://openalex.org/I37553959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050703311","display_name":"Benjamin Blunier","orcid":null},"institutions":[{"id":"https://openalex.org/I37553959","display_name":"Universit\u00e9 de technologie de belfort-montb\u00e9liard","ror":"https://ror.org/05bn3m307","country_code":"FR","type":"education","lineage":["https://openalex.org/I37553959"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Benjamin Blunier","raw_affiliation_strings":["Institut de Recherche sur les Transports, l'Energie et la Societe (IRTES-SeT), Universite de Technologie de Belfort-Montbeliard, Belfort, France","Inst. de Rech. sur les Transp., l'Energie et la Soc. (IRTES-SeT), Univ. de Technol. de Belfort Montbeliard (UTBM), Belfort, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut de Recherche sur les Transports, l'Energie et la Societe (IRTES-SeT), Universite de Technologie de Belfort-Montbeliard, Belfort, France","institution_ids":["https://openalex.org/I37553959"]},{"raw_affiliation_string":"Inst. de Rech. sur les Transp., l'Energie et la Soc. (IRTES-SeT), Univ. de Technol. de Belfort Montbeliard (UTBM), Belfort, France","institution_ids":["https://openalex.org/I37553959"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112380500","display_name":"Radu T\u00eernovan","orcid":"https://orcid.org/0000-0002-4970-1647"},"institutions":[{"id":"https://openalex.org/I158333966","display_name":"Technical University of Cluj-Napoca","ror":"https://ror.org/03r8nwp71","country_code":"RO","type":"education","lineage":["https://openalex.org/I158333966"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Radu Tirnovan","raw_affiliation_strings":["Electric Power System Department, Technical University of Cluj-Napoca, Cluj, Romania","Electr. Power Syst. Dept., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power System Department, Technical University of Cluj-Napoca, Cluj, Romania","institution_ids":["https://openalex.org/I158333966"]},{"raw_affiliation_string":"Electr. Power Syst. Dept., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania","institution_ids":["https://openalex.org/I158333966"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.14273151,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"54","issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.669222354888916},{"id":"https://openalex.org/keywords/plug-and-play","display_name":"Plug and play","score":0.6258727312088013},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.6034337282180786},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5711469650268555},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4712693393230438},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.46000200510025024},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.44708141684532166},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.4452725350856781},{"id":"https://openalex.org/keywords/state-of-charge","display_name":"State of charge","score":0.4217792749404907},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.37982332706451416},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.32112061977386475},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3067091107368469},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.25842049717903137},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.1429193913936615},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.13781246542930603}],"concepts":[{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.669222354888916},{"id":"https://openalex.org/C2780070844","wikidata":"https://www.wikidata.org/wiki/Q857815","display_name":"Plug and play","level":2,"score":0.6258727312088013},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.6034337282180786},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5711469650268555},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4712693393230438},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.46000200510025024},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.44708141684532166},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4452725350856781},{"id":"https://openalex.org/C2776582896","wikidata":"https://www.wikidata.org/wiki/Q5368536","display_name":"State of charge","level":4,"score":0.4217792749404907},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.37982332706451416},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.32112061977386475},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3067091107368469},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25842049717903137},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.1429193913936615},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.13781246542930603},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465637","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465637","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8899999856948853,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1965928180","https://openalex.org/W1970635216","https://openalex.org/W1971488724","https://openalex.org/W1974632557","https://openalex.org/W2000365330","https://openalex.org/W2017621325","https://openalex.org/W2017749620","https://openalex.org/W2032561488","https://openalex.org/W2039815011","https://openalex.org/W2046000995","https://openalex.org/W2088528049","https://openalex.org/W2095030391","https://openalex.org/W2103856062","https://openalex.org/W2113761147","https://openalex.org/W2119208341","https://openalex.org/W2134945310","https://openalex.org/W2134949919","https://openalex.org/W2135335961","https://openalex.org/W2142086443","https://openalex.org/W2162555711","https://openalex.org/W2170508670","https://openalex.org/W2490854169"],"related_works":["https://openalex.org/W2029283450","https://openalex.org/W2095163076","https://openalex.org/W3017124762","https://openalex.org/W3097919110","https://openalex.org/W2021194995","https://openalex.org/W4221107878","https://openalex.org/W2943443863","https://openalex.org/W4285489651","https://openalex.org/W2036913477","https://openalex.org/W2348871738"],"abstract_inverted_index":{"The":[0,20,54,73,128],"paper":[1],"deals":[2],"with":[3],"a":[4,9,58,62],"distributed":[5],"control":[6,55,126,132],"strategy":[7,56,60,77],"for":[8],"grid-connected":[10],"hybrid":[11,25],"system":[12,26,121,129],"composed":[13],"of":[14,44,64,89,94],"renewable":[15],"energy":[16,21],"sources":[17],"and":[18,48,68,138],"batteries.":[19],"balance":[22],"in":[23,75,119,124],"the":[24,31,38,42,45,49,87,90,92,95,99,104,120,125,131,134],"is":[27,57,78,81,98],"obtained":[28],"by":[29],"regulating":[30],"dc-bus":[32],"voltage.":[33],"In":[34],"this":[35,76],"study,":[36],"all":[37,142],"elements":[39,88,106],"can":[40],"ensure":[41],"stability":[43],"DC-bus":[46,96],"voltage":[47,97],"grid":[50],"interventions":[51],"are":[52,66,141],"reduced.":[53],"rule-based":[59],"where":[61],"set":[63],"rules":[65],"defined":[67],"implemented":[69],"using":[70],"state":[71],"machines.":[72],"novelty":[74],"that":[79,102],"there":[80],"no":[82],"specific":[83],"communication":[84],"network":[85],"between":[86],"system,":[91],"value":[93],"only":[100],"information":[101],"allows":[103],"several":[105],"to":[107,112],"interact.":[108],"This":[109],"condition":[110],"permits":[111],"easily":[113],"plug":[114],"or":[115],"unplug":[116],"an":[117],"element":[118],"without":[122],"changes":[123],"scheme.":[127],"configuration,":[130],"method,":[133],"simulation":[135],"results,":[136],"analysis":[137],"future":[139],"perspectives":[140],"presented.":[143]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
