{"id":"https://openalex.org/W2017118676","doi":"https://doi.org/10.1109/isgteurope.2012.6465620","title":"An application of robust power system security to power system operation for high-penetration of PV","display_name":"An application of robust power system security to power system operation for high-penetration of PV","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2017118676","doi":"https://doi.org/10.1109/isgteurope.2012.6465620","mag":"2017118676"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2012.6465620","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465620","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048381111","display_name":"Yoshiharu Okumoto","orcid":null},"institutions":[{"id":"https://openalex.org/I2799687715","display_name":"Chugoku Electric Power (Japan)","ror":"https://ror.org/02va37h22","country_code":"JP","type":"company","lineage":["https://openalex.org/I2799687715"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Yoshiharu Okumoto","raw_affiliation_strings":["Chugoku Electric Power Company, Inc., Hiroshima, Japan","Chugoku Electr. Power Co., Hiroshima, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chugoku Electric Power Company, Inc., Hiroshima, Japan","institution_ids":["https://openalex.org/I2799687715"]},{"raw_affiliation_string":"Chugoku Electr. Power Co., Hiroshima, Japan","institution_ids":["https://openalex.org/I2799687715"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000225177","display_name":"Naoto Yorino","orcid":"https://orcid.org/0000-0002-0288-6605"},"institutions":[{"id":"https://openalex.org/I113306721","display_name":"Hiroshima University","ror":"https://ror.org/03t78wx29","country_code":"JP","type":"education","lineage":["https://openalex.org/I113306721"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Naoto Yorino","raw_affiliation_strings":["Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]},{"raw_affiliation_string":"Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077026455","display_name":"Yoshifumi Zoka","orcid":"https://orcid.org/0000-0001-9487-3328"},"institutions":[{"id":"https://openalex.org/I113306721","display_name":"Hiroshima University","ror":"https://ror.org/03t78wx29","country_code":"JP","type":"education","lineage":["https://openalex.org/I113306721"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Yoshifumi Zoka","raw_affiliation_strings":["Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]},{"raw_affiliation_string":"Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028988295","display_name":"Yutaka Sasaki","orcid":"https://orcid.org/0000-0002-0963-8188"},"institutions":[{"id":"https://openalex.org/I113306721","display_name":"Hiroshima University","ror":"https://ror.org/03t78wx29","country_code":"JP","type":"education","lineage":["https://openalex.org/I113306721"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Yutaka Sasaki","raw_affiliation_strings":["Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]},{"raw_affiliation_string":"Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110479982","display_name":"Toshihiro Yamanaka","orcid":null},"institutions":[{"id":"https://openalex.org/I113306721","display_name":"Hiroshima University","ror":"https://ror.org/03t78wx29","country_code":"JP","type":"education","lineage":["https://openalex.org/I113306721"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Toshihiro Yamanaka","raw_affiliation_strings":["Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]},{"raw_affiliation_string":"Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112065514","display_name":"Tomohisa Akiyoshi","orcid":null},"institutions":[{"id":"https://openalex.org/I113306721","display_name":"Hiroshima University","ror":"https://ror.org/03t78wx29","country_code":"JP","type":"education","lineage":["https://openalex.org/I113306721"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Tomohisa Akiyoshi","raw_affiliation_strings":["Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, Hiroshima University, Higashihiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]},{"raw_affiliation_string":"Grad. Sch. of Eng., Hiroshima University, Higashi-Hiroshima, Japan","institution_ids":["https://openalex.org/I113306721"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.8862,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.90972603,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"4","issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/penetration","display_name":"Penetration (warfare)","score":0.7859457731246948},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6137776970863342},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5485473871231079},{"id":"https://openalex.org/keywords/security-system","display_name":"Security system","score":0.4868849813938141},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4317770004272461},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.3784072697162628},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.32366836071014404},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18615272641181946},{"id":"https://openalex.org/keywords/operations-research","display_name":"Operations research","score":0.1129598617553711}],"concepts":[{"id":"https://openalex.org/C80107235","wikidata":"https://www.wikidata.org/wiki/Q7162625","display_name":"Penetration (warfare)","level":2,"score":0.7859457731246948},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6137776970863342},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5485473871231079},{"id":"https://openalex.org/C2984192347","wikidata":"https://www.wikidata.org/wiki/Q1497831","display_name":"Security system","level":2,"score":0.4868849813938141},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4317770004272461},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.3784072697162628},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32366836071014404},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18615272641181946},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.1129598617553711},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2012.6465620","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2012.6465620","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W1981504316","https://openalex.org/W1981924668","https://openalex.org/W1986455546","https://openalex.org/W1990064277","https://openalex.org/W2000862383","https://openalex.org/W2006292626","https://openalex.org/W2007324215","https://openalex.org/W2029780375","https://openalex.org/W2037613877","https://openalex.org/W2039535513","https://openalex.org/W2044801777","https://openalex.org/W2111278012","https://openalex.org/W2118524339","https://openalex.org/W2126447590","https://openalex.org/W2131561895","https://openalex.org/W2134037405","https://openalex.org/W2139329332","https://openalex.org/W2163232949","https://openalex.org/W2167200381","https://openalex.org/W2169988158","https://openalex.org/W2174002231","https://openalex.org/W2175698703","https://openalex.org/W2312424122","https://openalex.org/W2504348151","https://openalex.org/W2511259445","https://openalex.org/W2524641040","https://openalex.org/W3015208309","https://openalex.org/W3015653100","https://openalex.org/W3141830733","https://openalex.org/W6652339476","https://openalex.org/W6680022785","https://openalex.org/W6725309832"],"related_works":["https://openalex.org/W2035753757","https://openalex.org/W2057618511","https://openalex.org/W2382736794","https://openalex.org/W4292200990","https://openalex.org/W2414313142","https://openalex.org/W2383037148","https://openalex.org/W2357339104","https://openalex.org/W2529169372","https://openalex.org/W2155742919","https://openalex.org/W1914681266"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,52,104],"method":[4,98],"of":[5,13,18,57,91,95],"analyzing":[6],"the":[7,11,26,32,41,47,64,77,84,89,96],"N-1":[8,33,48,65,78],"security":[9,34,49,66,79,85],"under":[10],"circumstances":[12],"PV":[14,44],"penetration.":[15],"The":[16,93],"concept":[17,90],"Robust":[19],"Power":[20],"System":[21],"Security":[22],"(RS)":[23],"proposed":[24,97],"by":[25,82],"authors":[27],"is":[28,37,60,99],"used":[29],"to":[30,62,75],"evaluate":[31],"quantitatively.":[35],"It":[36],"shown":[38],"that":[39],"(1)":[40],"relationship":[42],"between":[43],"penetration":[45],"and":[46,67],"results":[50],"in":[51],"clear":[53],"trade-off,":[54],"(2)":[55],"installation":[56],"storage":[58],"batteries":[59],"effective":[61],"enhance":[63],"(3)":[68],"power":[69],"system":[70],"operators":[71],"will":[72],"be":[73],"able":[74],"monitor":[76],"condition":[80],"directly":[81],"visualizing":[83],"regions":[86],"gained":[87],"from":[88],"RS.":[92],"effectiveness":[94],"demonstrated":[100],"through":[101],"simulations":[102],"using":[103],"three":[105],"machine":[106],"system.":[107]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
