{"id":"https://openalex.org/W1993968967","doi":"https://doi.org/10.1109/isgteurope.2011.6162694","title":"Building control and storage management with dynamic tariffs for shaping demand response","display_name":"Building control and storage management with dynamic tariffs for shaping demand response","publication_year":2011,"publication_date":"2011-12-01","ids":{"openalex":"https://openalex.org/W1993968967","doi":"https://doi.org/10.1109/isgteurope.2011.6162694","mag":"1993968967"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2011.6162694","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2011.6162694","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059534916","display_name":"Frauke Oldewurtel","orcid":null},"institutions":[{"id":"https://openalex.org/I35440088","display_name":"ETH Zurich","ror":"https://ror.org/05a28rw58","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I35440088"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Frauke Oldewurtel","raw_affiliation_strings":["Automatic Control Laboratory, ETH Zurich, Zurich, Switzerland","Automatic Control Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Automatic Control Laboratory, ETH Zurich, Zurich, Switzerland","institution_ids":["https://openalex.org/I35440088"]},{"raw_affiliation_string":"Automatic Control Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland","institution_ids":["https://openalex.org/I35440088"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074624526","display_name":"Andreas Ulbig","orcid":"https://orcid.org/0000-0001-5834-1842"},"institutions":[{"id":"https://openalex.org/I35440088","display_name":"ETH Zurich","ror":"https://ror.org/05a28rw58","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I35440088"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Andreas Ulbig","raw_affiliation_strings":["Power Systems Laboratory, ETH Zurich, Zurich, Switzerland","Power Systems Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Systems Laboratory, ETH Zurich, Zurich, Switzerland","institution_ids":["https://openalex.org/I35440088"]},{"raw_affiliation_string":"Power Systems Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland","institution_ids":["https://openalex.org/I35440088"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025946191","display_name":"Manfred Morari","orcid":"https://orcid.org/0000-0002-7696-5058"},"institutions":[{"id":"https://openalex.org/I35440088","display_name":"ETH Zurich","ror":"https://ror.org/05a28rw58","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I35440088"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Manfred Morari","raw_affiliation_strings":["Automatic Control Laboratory, ETH Zurich, Zurich, Switzerland","Automatic Control Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Automatic Control Laboratory, ETH Zurich, Zurich, Switzerland","institution_ids":["https://openalex.org/I35440088"]},{"raw_affiliation_string":"Automatic Control Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland","institution_ids":["https://openalex.org/I35440088"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089346574","display_name":"G\u00f6ran Andersson","orcid":"https://orcid.org/0000-0002-7715-7087"},"institutions":[{"id":"https://openalex.org/I35440088","display_name":"ETH Zurich","ror":"https://ror.org/05a28rw58","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I35440088"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Goran Andersson","raw_affiliation_strings":["Power Systems Laboratory, ETH Zurich, Zurich, Switzerland","Power Systems Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Systems Laboratory, ETH Zurich, Zurich, Switzerland","institution_ids":["https://openalex.org/I35440088"]},{"raw_affiliation_string":"Power Systems Laboratory, ETH Zurich, Physikstrasse 3, 8092, Switzerland","institution_ids":["https://openalex.org/I35440088"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I35440088"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":41,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.7722585201263428},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.7698301672935486},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.7336370944976807},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.5530878305435181},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5304424166679382},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.5253992676734924},{"id":"https://openalex.org/keywords/load-shifting","display_name":"Load shifting","score":0.5209056735038757},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.5003631114959717},{"id":"https://openalex.org/keywords/consumption","display_name":"Consumption (sociology)","score":0.4737316370010376},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.441829651594162},{"id":"https://openalex.org/keywords/environmental-economics","display_name":"Environmental economics","score":0.4349663257598877},{"id":"https://openalex.org/keywords/electricity-retailing","display_name":"Electricity retailing","score":0.4310978651046753},{"id":"https://openalex.org/keywords/stand-alone-power-system","display_name":"Stand-alone power system","score":0.4214906692504883},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3585337996482849},{"id":"https://openalex.org/keywords/electricity-market","display_name":"Electricity market","score":0.3530504107475281},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2122795283794403},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.15944132208824158},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.1262856423854828},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.1104046106338501},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09907001256942749}],"concepts":[{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.7722585201263428},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.7698301672935486},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.7336370944976807},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.5530878305435181},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5304424166679382},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.5253992676734924},{"id":"https://openalex.org/C2777030403","wikidata":"https://www.wikidata.org/wiki/Q17099419","display_name":"Load shifting","level":3,"score":0.5209056735038757},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.5003631114959717},{"id":"https://openalex.org/C30772137","wikidata":"https://www.wikidata.org/wiki/Q5164762","display_name":"Consumption (sociology)","level":2,"score":0.4737316370010376},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.441829651594162},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.4349663257598877},{"id":"https://openalex.org/C57101690","wikidata":"https://www.wikidata.org/wiki/Q2356921","display_name":"Electricity retailing","level":4,"score":0.4310978651046753},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.4214906692504883},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3585337996482849},{"id":"https://openalex.org/C146733006","wikidata":"https://www.wikidata.org/wiki/Q676081","display_name":"Electricity market","level":3,"score":0.3530504107475281},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2122795283794403},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.15944132208824158},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.1262856423854828},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.1104046106338501},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09907001256942749},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C36289849","wikidata":"https://www.wikidata.org/wiki/Q34749","display_name":"Social science","level":1,"score":0.0},{"id":"https://openalex.org/C144024400","wikidata":"https://www.wikidata.org/wiki/Q21201","display_name":"Sociology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C187736073","wikidata":"https://www.wikidata.org/wiki/Q2920921","display_name":"Management","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope.2011.6162694","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2011.6162694","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","raw_type":"proceedings-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.718.824","is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.718.824","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.eeh.ee.ethz.ch/uploads/tx_ethpublications/ISGT2011_FO_AU_public.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1488604512","https://openalex.org/W1554314508","https://openalex.org/W1561941139","https://openalex.org/W2017428530","https://openalex.org/W2029264889","https://openalex.org/W2054968295","https://openalex.org/W2139091700","https://openalex.org/W2167005602","https://openalex.org/W2213594914","https://openalex.org/W6680664684"],"related_works":["https://openalex.org/W2417546775","https://openalex.org/W2035833777","https://openalex.org/W3112567715","https://openalex.org/W2032085210","https://openalex.org/W2892382322","https://openalex.org/W3127929673","https://openalex.org/W4378805685","https://openalex.org/W39487273","https://openalex.org/W4239205706","https://openalex.org/W4285816455"],"abstract_inverted_index":{"The":[0,18,56,75,145],"results":[1],"from":[2,71],"a":[3,21,31,36,61],"proof-of-concept":[4],"study":[5,76],"combining":[6],"modern":[7],"building":[8,22,138],"automation":[9,23],"systems":[10,119],"(BAS)":[11],"with":[12],"dynamic":[13],"electricity":[14,28,99,126],"tariffs":[15],"are":[16,115,120,134],"presented.":[17],"use":[19],"of":[20,30,69,81,86,98,125,155,158],"system":[24],"that":[25],"optimizes":[26],"the":[27,79,84,96,151,156],"demand":[29,127],"retail":[32,103],"end-consumer":[33],"while":[34],"managing":[35],"local":[37],"battery":[38,118,140],"unit":[39],"and":[40,50,108,142],"respecting":[41],"all":[42],"comfort":[43],"constraints,":[44],"e.g.,":[45],"on":[46,78,95,150],"room":[47],"temperature,":[48],"illuminance,":[49],"indoor":[51],"air":[52],"quality,":[53],"is":[54,58,160],"proposed.":[55],"optimization":[57],"done":[59],"in":[60,83],"fully":[62],"automated":[63],"fashion,":[64],"i.e.":[65,106],"without":[66],"any":[67],"need":[68],"action":[70],"an":[72],"external":[73],"operator.":[74],"focuses":[77],"situation":[80],"end-consumers":[82],"city":[85,157],"Zurich,":[87],"Switzerland.":[88],"Demand":[89],"shifting":[90,148],"as":[91,93,122],"well":[92],"effects":[94],"cost":[97],"consumption":[100],"for":[101,136],"different":[102,137],"consumer":[104],"groups,":[105],"households":[107],"offices":[109],"using":[110],"their":[111],"typical":[112],"usage":[113,143],"profiles":[114],"assessed.":[116],"In-house":[117],"introduced":[121],"additional":[123],"means":[124],"flexibility.":[128],"Extensive":[129],"simulations":[130],"(500+":[131],"full-year":[132],"simulations)":[133],"performed":[135],"types,":[139,141],"profiles.":[144],"overall":[146],"load":[147,153],"effect":[149],"aggregated":[152],"curve":[154],"Zurich":[159],"evaluated.":[161]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":7},{"year":2013,"cited_by_count":4}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}