{"id":"https://openalex.org/W1972817625","doi":"https://doi.org/10.1109/isgteurope.2010.5638936","title":"Intelligent system for the on-line real time monitoring of high voltage substations","display_name":"Intelligent system for the on-line real time monitoring of high voltage substations","publication_year":2010,"publication_date":"2010-10-01","ids":{"openalex":"https://openalex.org/W1972817625","doi":"https://doi.org/10.1109/isgteurope.2010.5638936","mag":"1972817625"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2010.5638936","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2010.5638936","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041144997","display_name":"Constantin Moldoveanu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Constantin Moldoveanu","raw_affiliation_strings":["NOVA INDUSTRIAL SA, Research Department, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, Research Department, Bucharest, Romania","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046683517","display_name":"Virgil Brezoianu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Virgil Brezoianu","raw_affiliation_strings":["NOVA INDUSTRIAL SA, Production Department, Bucharest, Romania","NOVA INDUSTRIAL SA, Production Department, Bucharest, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, Production Department, Bucharest, Romania","institution_ids":[]},{"raw_affiliation_string":"NOVA INDUSTRIAL SA, Production Department, Bucharest, Bucharest, Romania","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102044559","display_name":"Aurelian Vasile","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Aurelian Vasile","raw_affiliation_strings":["NOVA INDUSTRIAL SA, IT Department, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, IT Department, Bucharest, Romania","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006972396","display_name":"Victor Ursianu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Victor Ursianu","raw_affiliation_strings":["NOVA INDUSTRIAL SA, IT Department, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, IT Department, Bucharest, Romania","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067185776","display_name":"Florin Goni","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Florin Goni","raw_affiliation_strings":["NOVA INDUSTRIAL SA, High Voltage Equipment Department, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, High Voltage Equipment Department, Bucharest, Romania","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112083281","display_name":"Constantin Radu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Constantin Radu","raw_affiliation_strings":["NOVA INDUSTRIAL SA, Technical Department, Bucharest, Romania","INDUSTRIAL SA, Technical Department, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, Technical Department, Bucharest, Romania","institution_ids":[]},{"raw_affiliation_string":"INDUSTRIAL SA, Technical Department, Bucharest, Romania","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5053741774","display_name":"Irene Ionita","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Irene Ionita","raw_affiliation_strings":["NOVA INDUSTRIAL SA, Executive Department, Bucharest, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NOVA INDUSTRIAL SA, Executive Department, Bucharest, Romania","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5632,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.70105646,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.8773000240325928,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.8773000240325928,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14091","display_name":"Industrial and Mining Safety","score":0.866599977016449,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13891","display_name":"Engineering Diagnostics and Reliability","score":0.8582000136375427,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.7212240695953369},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5698273777961731},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5660913586616516},{"id":"https://openalex.org/keywords/electrical-equipment","display_name":"Electrical equipment","score":0.5529218912124634},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5477293729782104},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.534906268119812},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.5146680474281311},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.509610652923584},{"id":"https://openalex.org/keywords/electric-power","display_name":"Electric power","score":0.4854450821876526},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4516848027706146},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.4314459264278412},{"id":"https://openalex.org/keywords/electric-power-industry","display_name":"Electric power industry","score":0.4122607111930847},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3542024493217468},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.300692617893219},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.221543550491333}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.7212240695953369},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5698273777961731},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5660913586616516},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.5529218912124634},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5477293729782104},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.534906268119812},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.5146680474281311},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.509610652923584},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.4854450821876526},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4516848027706146},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4314459264278412},{"id":"https://openalex.org/C170777988","wikidata":"https://www.wikidata.org/wiki/Q2316331","display_name":"Electric power industry","level":3,"score":0.4122607111930847},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3542024493217468},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.300692617893219},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.221543550491333},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2010.5638936","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2010.5638936","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2108282770"],"related_works":["https://openalex.org/W2142945692","https://openalex.org/W2356512289","https://openalex.org/W1629635549","https://openalex.org/W2348819278","https://openalex.org/W2379250692","https://openalex.org/W2897016074","https://openalex.org/W2374094183","https://openalex.org/W2378187163","https://openalex.org/W2352170327","https://openalex.org/W2356781843"],"abstract_inverted_index":{"The":[0,130],"advanced":[1],"age":[2],"of":[3,20,50,55,69,88,103,123,136,144,155,166,197],"electrical":[4,57,127,150],"equipment":[5,58,71,125,146],"from":[6,72,126,147],"the":[7,14,18,22,26,33,37,46,51,56,67,70,76,83,99,104,109,134,137,153,156,163],"high":[8,148],"voltage":[9,149,174],"power":[10,15,60,100,128,167,199],"stations,":[11,61],"correlated":[12],"with":[13,32],"sector":[16],"restructure,":[17],"reduction":[19],"personnel,":[21],"increasing":[23],"competition":[24],"in":[25,59,62],"service":[27],"market,":[28],"and":[29,43,85,178,201],"more":[30],"recently":[31],"economic":[34],"crisis,":[35],"determine":[36],"need":[38,77],"to":[39,64,74,81,91,107,116,141],"introduce":[40],"new":[41],"solutions":[42],"criteria":[44],"for":[45,78,120,162,194],"correct":[47,94],"on-line":[48,121,142,164,195],"evaluation":[49],"current":[52,131,176],"technical":[53,86],"condition":[54],"order":[63],"assess":[65],"correctly":[66],"withdrawal":[68],"operation,":[73],"plan":[75],"maintenance":[79],"works,":[80,90],"increase":[82],"financial":[84],"efficiency":[87],"these":[89],"support":[92],"a":[93],"operation":[95],"risk":[96],"evaluation.":[97],"For":[98],"companies,":[101],"one":[102],"main":[105],"methods":[106],"obtain":[108],"mentioned":[110],"benefits,":[111],"including":[112],"cost":[113],"reduction,":[114],"is":[115],"use":[117],"intelligent":[118,138,182],"systems":[119,184],"monitoring":[122,143,165,183,196],"primary":[124,145],"stations.":[129],"paper":[132],"describes":[133],"parts":[135],"system,":[139],"dedicated":[140],"substations,":[151],"respectively":[152],"components":[154],"complex":[157],"system":[158,193],"NOVA":[159],"EMCSIT,":[160],"designed":[161],"transformers,":[168],"shunt":[169],"reactors,":[170],"circuit":[171],"breakers,":[172],"disconnectors,":[173],"&":[175],"transformers":[177],"surge":[179],"arresters.":[180],"These":[181],"can":[185],"be":[186],"used":[187],"stand-alone":[188],"or":[189],"within":[190],"an":[191],"integrated":[192],"electric":[198],"stations":[200],"substations":[202],"\u2014":[203],"Smart":[204],"Grids.":[205]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
