{"id":"https://openalex.org/W4360584106","doi":"https://doi.org/10.1109/isgt51731.2023.10066347","title":"Characterizing HVDC Transmission Flexibility under Extreme Operating Conditions","display_name":"Characterizing HVDC Transmission Flexibility under Extreme Operating Conditions","publication_year":2023,"publication_date":"2023-01-16","ids":{"openalex":"https://openalex.org/W4360584106","doi":"https://doi.org/10.1109/isgt51731.2023.10066347"},"language":"en","primary_location":{"id":"doi:10.1109/isgt51731.2023.10066347","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt51731.2023.10066347","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101634258","display_name":"Quan Nguyen","orcid":"https://orcid.org/0000-0003-4776-9557"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Quan Nguyen","raw_affiliation_strings":["Pacific Northwest National Laboratory,Richland,WA,USA,99354"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory,Richland,WA,USA,99354","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025168429","display_name":"Pavel Etingov","orcid":"https://orcid.org/0000-0002-2169-3075"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Pavel Etingov","raw_affiliation_strings":["Pacific Northwest National Laboratory,Richland,WA,USA,99354"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory,Richland,WA,USA,99354","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5085217555","display_name":"Marcelo Elizondo","orcid":"https://orcid.org/0000-0002-6621-252X"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Marcelo A. Elizondo","raw_affiliation_strings":["Pacific Northwest National Laboratory,Richland,WA,USA,99354"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory,Richland,WA,USA,99354","institution_ids":["https://openalex.org/I142606810"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I142606810"],"apc_list":null,"apc_paid":null,"fwci":1.0808,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.6749544,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9921000003814697,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9828000068664551,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.8693407773971558},{"id":"https://openalex.org/keywords/resilience","display_name":"Resilience (materials science)","score":0.7203348875045776},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.7095516324043274},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.6838991641998291},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6615512371063232},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6538307070732117},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.645591139793396},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.6274874210357666},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.5792418718338013},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5462002158164978},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.4939003586769104},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.4683484435081482},{"id":"https://openalex.org/keywords/resource","display_name":"Resource (disambiguation)","score":0.4161268472671509},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3334059417247772},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33030664920806885},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.28499579429626465},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.26899710297584534},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.22831052541732788},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.11514347791671753},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.09694227576255798}],"concepts":[{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.8693407773971558},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.7203348875045776},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.7095516324043274},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.6838991641998291},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6615512371063232},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6538307070732117},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.645591139793396},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.6274874210357666},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5792418718338013},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5462002158164978},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.4939003586769104},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.4683484435081482},{"id":"https://openalex.org/C206345919","wikidata":"https://www.wikidata.org/wiki/Q20380951","display_name":"Resource (disambiguation)","level":2,"score":0.4161268472671509},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3334059417247772},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33030664920806885},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.28499579429626465},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.26899710297584534},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.22831052541732788},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.11514347791671753},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.09694227576255798},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt51731.2023.10066347","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt51731.2023.10066347","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G125460123","display_name":null,"funder_award_id":"DE-AC05\u201376RL01830","funder_id":"https://openalex.org/F4320306084","funder_display_name":"U.S. Department of Energy"}],"funders":[{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"},{"id":"https://openalex.org/F4320338354","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1571403844","https://openalex.org/W1973253821","https://openalex.org/W1984123216","https://openalex.org/W2983666250","https://openalex.org/W2989867974"],"related_works":["https://openalex.org/W1597126268","https://openalex.org/W2481367499","https://openalex.org/W2112932084","https://openalex.org/W4282840351","https://openalex.org/W2974248140","https://openalex.org/W2492500466","https://openalex.org/W1971482830","https://openalex.org/W2730791322","https://openalex.org/W3135260911","https://openalex.org/W2320078436"],"abstract_inverted_index":{"System":[0],"operators":[1],"rely":[2],"on":[3],"system":[4,49,64,78,95],"flexibility,":[5],"traditionally":[6],"mainly":[7],"from":[8,18,87],"generation,":[9],"to":[10,23,46,51,60,63,84,108,121,123],"handle":[11],"unexpected":[12],"reliability":[13],"and":[14,29,89,114],"resilience":[15],"events,":[16],"ranging":[17],"excessive":[19],"resource":[20],"forecast":[21],"errors":[22],"extreme":[24,94],"events":[25],"like":[26],"heatwaves,":[27],"earthquakes,":[28],"cyberattacks.":[30],"Flexible":[31],"transmission,":[32],"such":[33],"as":[34,81],"controllable":[35],"high":[36],"voltage":[37],"direct":[38],"current":[39],"(HVDC)":[40],"transmission":[41,102],"systems":[42],"present":[43],"an":[44,82],"opportunity":[45],"increase":[47],"overall":[48],"flexibility":[50,65,103],"accommodate":[52],"operational":[53],"challenges.":[54],"This":[55],"paper":[56],"provides":[57],"a":[58],"methodology":[59],"study":[61,85],"contributions":[62,86],"by":[66],"controllable,":[67],"power":[68],"electronics":[69],"based":[70],"transmission.":[71],"The":[72],"Western":[73],"Electricity":[74],"Coordinating":[75],"Council":[76],"(WECC)":[77],"is":[79,98],"used":[80],"example":[83],"existing":[88],"future":[90],"HVDC":[91,101],"lines.":[92],"Under":[93],"conditions,":[96],"it":[97],"identified":[99],"that":[100],"can":[104],"contribute":[105],"with":[106],"24.8":[107],"28%":[109],"of":[110],"avoided":[111],"unserved":[112],"energy,":[113],"in":[115],"some":[116],"areas,":[117],"the":[118],"benefits":[119],"amount":[120],"50":[122],"70%.":[124]},"counts_by_year":[{"year":2024,"cited_by_count":2}],"updated_date":"2026-08-01T09:00:35.917206","created_date":"2025-10-10T00:00:00"}