{"id":"https://openalex.org/W4285103623","doi":"https://doi.org/10.1109/isgt50606.2022.9817537","title":"Cost Analysis of DCFC Fast Charging Station Power Rates for Workplace Charging","display_name":"Cost Analysis of DCFC Fast Charging Station Power Rates for Workplace Charging","publication_year":2022,"publication_date":"2022-04-24","ids":{"openalex":"https://openalex.org/W4285103623","doi":"https://doi.org/10.1109/isgt50606.2022.9817537"},"language":"en","primary_location":{"id":"doi:10.1109/isgt50606.2022.9817537","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt50606.2022.9817537","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://rgu-repository.worktribe.com/output/1713054","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075440140","display_name":"Sadik Kucuksari","orcid":"https://orcid.org/0000-0003-4659-7407"},"institutions":[{"id":"https://openalex.org/I119234918","display_name":"University of Northern Iowa","ror":"https://ror.org/02h4qpx12","country_code":"US","type":"education","lineage":["https://openalex.org/I119234918"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Sadik Kucuksari","raw_affiliation_strings":["University of Northern Iowa,Department of Technology,Cedar Falls,IA,USA","Department of Technology, University of Northern Iowa, Cedar Falls, IA, USA"],"affiliations":[{"raw_affiliation_string":"University of Northern Iowa,Department of Technology,Cedar Falls,IA,USA","institution_ids":["https://openalex.org/I119234918"]},{"raw_affiliation_string":"Department of Technology, University of Northern Iowa, Cedar Falls, IA, USA","institution_ids":["https://openalex.org/I119234918"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5086094431","display_name":"Nuh Erdo\u011fan","orcid":"https://orcid.org/0000-0003-1621-2748"},"institutions":[{"id":"https://openalex.org/I522815984","display_name":"Robert Gordon University","ror":"https://ror.org/04f0qj703","country_code":"GB","type":"education","lineage":["https://openalex.org/I522815984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Nuh Erdogan","raw_affiliation_strings":["Robert Gordon University,School of Engineering,Aberdeen,UK,AB10 7GJ"],"affiliations":[{"raw_affiliation_string":"Robert Gordon University,School of Engineering,Aberdeen,UK,AB10 7GJ","institution_ids":["https://openalex.org/I522815984"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5075440140"],"corresponding_institution_ids":["https://openalex.org/I119234918"],"apc_list":null,"apc_paid":null,"fwci":0.2744,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.52007326,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11690","display_name":"Advanced battery technologies research","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cost-of-electricity-by-source","display_name":"Cost of electricity by source","score":0.5432712435722351},{"id":"https://openalex.org/keywords/peak-demand","display_name":"Peak demand","score":0.5197262763977051},{"id":"https://openalex.org/keywords/on-demand","display_name":"On demand","score":0.4619264006614685},{"id":"https://openalex.org/keywords/power-demand","display_name":"Power demand","score":0.4577758014202118},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4228476583957672},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4159208834171295},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3729667663574219},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3584098815917969},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.33461472392082214},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3199618458747864},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24155840277671814},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.15924879908561707}],"concepts":[{"id":"https://openalex.org/C5979214","wikidata":"https://www.wikidata.org/wiki/Q126932","display_name":"Cost of electricity by source","level":4,"score":0.5432712435722351},{"id":"https://openalex.org/C147940328","wikidata":"https://www.wikidata.org/wiki/Q3393666","display_name":"Peak demand","level":3,"score":0.5197262763977051},{"id":"https://openalex.org/C2983523559","wikidata":"https://www.wikidata.org/wiki/Q410657","display_name":"On demand","level":2,"score":0.4619264006614685},{"id":"https://openalex.org/C2983317576","wikidata":"https://www.wikidata.org/wiki/Q1853339","display_name":"Power demand","level":4,"score":0.4577758014202118},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4228476583957672},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4159208834171295},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3729667663574219},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3584098815917969},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.33461472392082214},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3199618458747864},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24155840277671814},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.15924879908561707},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C49774154","wikidata":"https://www.wikidata.org/wiki/Q131765","display_name":"Multimedia","level":1,"score":0.0},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgt50606.2022.9817537","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt50606.2022.9817537","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},{"id":"pmh:oai:rgu-repository.worktribe.com:1713054","is_oa":true,"landing_page_url":"https://rgu-repository.worktribe.com/output/1713054","pdf_url":null,"source":{"id":"https://openalex.org/S4306400814","display_name":"Open Access Institutional Repository at Robert Gordon University (Robert Gordon University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I522815984","host_organization_name":"Robert Gordon University","host_organization_lineage":["https://openalex.org/I522815984"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"acceptedVersion"}],"best_oa_location":{"id":"pmh:oai:rgu-repository.worktribe.com:1713054","is_oa":true,"landing_page_url":"https://rgu-repository.worktribe.com/output/1713054","pdf_url":null,"source":{"id":"https://openalex.org/S4306400814","display_name":"Open Access Institutional Repository at Robert Gordon University (Robert Gordon University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I522815984","host_organization_name":"Robert Gordon University","host_organization_lineage":["https://openalex.org/I522815984"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"acceptedVersion"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.4000000059604645}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1993386761","https://openalex.org/W2025198719","https://openalex.org/W2610819615","https://openalex.org/W2909497079","https://openalex.org/W2955235260","https://openalex.org/W3083579434","https://openalex.org/W3125469821","https://openalex.org/W3187312764","https://openalex.org/W3203399525","https://openalex.org/W4205202994"],"related_works":["https://openalex.org/W3166407621","https://openalex.org/W3091486096","https://openalex.org/W4387705799","https://openalex.org/W245708997","https://openalex.org/W2550496390","https://openalex.org/W2021020482","https://openalex.org/W3137005026","https://openalex.org/W2169697591","https://openalex.org/W2548196388","https://openalex.org/W2121515951"],"abstract_inverted_index":{"DC":[0],"fast":[1],"charging":[2,11,67],"(DCFC)":[3],"station":[4,80],"becomes":[5],"prominent":[6],"thanks":[7],"to":[8,113,121],"offering":[9],"faster":[10],"service.":[12],"However,":[13,129],"they":[14],"increase":[15],"the":[16,20,73,92,99,102,107,114,122,125,141],"peak":[17,108,142],"demand,":[18],"hence,":[19],"demand":[21,49,109,115,143],"charge":[22],"for":[23,56],"industrial":[24],"and":[25,51,95],"commercial":[26],"customers":[27],"increases.":[28],"This":[29,118],"study":[30],"analyses":[31],"cost":[32,62,77,88],"behaviors":[33,89],"of":[34,78,124],"various":[35,57],"DCFC":[36,79,87],"power":[37],"rates":[38,55],"(i.e.,":[39],"50":[40],"kW,":[41,43],"150":[42],"350":[44],"kW)":[45],"at":[46,81],"workplaces":[47],"under":[48],"metered":[50,116],"EV":[52,58,96,103],"specific":[53,104],"TOU":[54,126],"utilization.":[59,97],"An":[60],"optimal":[61],"model":[63],"with":[64,135,140],"proposed":[65],"interrupted":[66],"profile":[68],"is":[69,84,119],"presented":[70],"that":[71,86,138],"minimizes":[72],"daily":[74],"levelized":[75],"total":[76],"workplaces.":[82],"It":[83],"shown":[85],"differ":[90],"from":[91],"utility":[93],"rate":[94,105,127],"From":[98],"grid":[100],"perspective,":[101],"increases":[106],"considerably":[110],"as":[111],"compared":[112],"rate.":[117],"due":[120],"nature":[123],"design.":[128],"this":[130],"impact":[131],"can":[132],"be":[133],"minimized":[134],"solar":[136],"generation":[137],"coincides":[139],"hours.":[144]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}