{"id":"https://openalex.org/W3022294028","doi":"https://doi.org/10.1109/isgt45199.2020.9087768","title":"Topology Design Method for Super Grids based on experiences in China and North America","display_name":"Topology Design Method for Super Grids based on experiences in China and North America","publication_year":2020,"publication_date":"2020-02-01","ids":{"openalex":"https://openalex.org/W3022294028","doi":"https://doi.org/10.1109/isgt45199.2020.9087768","mag":"3022294028"},"language":"en","primary_location":{"id":"doi:10.1109/isgt45199.2020.9087768","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt45199.2020.9087768","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021204175","display_name":"Rodney Itiki","orcid":"https://orcid.org/0000-0002-7150-7584"},"institutions":[{"id":"https://openalex.org/I17974374","display_name":"Universidade de S\u00e3o Paulo","ror":"https://ror.org/036rp1748","country_code":"BR","type":"education","lineage":["https://openalex.org/I17974374"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Rodney Itiki","raw_affiliation_strings":["University of Sao Paulo"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Sao Paulo","institution_ids":["https://openalex.org/I17974374"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065327420","display_name":"Madhav Manjrekar","orcid":"https://orcid.org/0000-0002-6110-3113"},"institutions":[{"id":"https://openalex.org/I102149020","display_name":"University of North Carolina at Charlotte","ror":"https://ror.org/04dawnj30","country_code":"US","type":"education","lineage":["https://openalex.org/I102149020"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Madhav Manjrekar","raw_affiliation_strings":["Dept. Elec. & Comp. Eng., University of North Carolina, Charlotte, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. Elec. & Comp. Eng., University of North Carolina, Charlotte, USA","institution_ids":["https://openalex.org/I102149020"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017513661","display_name":"Silvio Giuseppe Di Santo","orcid":"https://orcid.org/0000-0002-2156-9920"},"institutions":[{"id":"https://openalex.org/I17974374","display_name":"Universidade de S\u00e3o Paulo","ror":"https://ror.org/036rp1748","country_code":"BR","type":"education","lineage":["https://openalex.org/I17974374"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Silvio Giuseppe Di Santo","raw_affiliation_strings":["Dept. Energy and Autom., University of Sao Paulo, Sao Paulo, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. Energy and Autom., University of Sao Paulo, Sao Paulo, Brazil","institution_ids":["https://openalex.org/I17974374"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035753762","display_name":"Luis Fernando Moreira Machado","orcid":null},"institutions":[{"id":"https://openalex.org/I17974374","display_name":"Universidade de S\u00e3o Paulo","ror":"https://ror.org/036rp1748","country_code":"BR","type":"education","lineage":["https://openalex.org/I17974374"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Luis F. M. Machado","raw_affiliation_strings":["Dept. Energy and Autom., University of Sao Paulo, Sao Paulo, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. Energy and Autom., University of Sao Paulo, Sao Paulo, Brazil","institution_ids":["https://openalex.org/I17974374"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.4313,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.77850174,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"70","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9811999797821045,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9653000235557556,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.6937007904052734},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.6625630259513855},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6604876518249512},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6272286176681519},{"id":"https://openalex.org/keywords/high-voltage","display_name":"High voltage","score":0.499739408493042},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.48804771900177},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.4796200692653656},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.47416701912879944},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.4367104768753052},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.42391863465309143},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.41828984022140503},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.41787847876548767},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.41185060143470764},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.2456287145614624},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.09500795602798462}],"concepts":[{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.6937007904052734},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.6625630259513855},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6604876518249512},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6272286176681519},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.499739408493042},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48804771900177},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.4796200692653656},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47416701912879944},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.4367104768753052},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.42391863465309143},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.41828984022140503},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41787847876548767},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.41185060143470764},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.2456287145614624},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.09500795602798462},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt45199.2020.9087768","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt45199.2020.9087768","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1855012108","https://openalex.org/W2082349328","https://openalex.org/W2127729571","https://openalex.org/W2257522626","https://openalex.org/W2315619298","https://openalex.org/W2558933202","https://openalex.org/W2622243942","https://openalex.org/W2794094788","https://openalex.org/W2937083194","https://openalex.org/W2941638743","https://openalex.org/W3008925785"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2005192856","https://openalex.org/W2095124237","https://openalex.org/W2540859271","https://openalex.org/W1992558323","https://openalex.org/W2796152272","https://openalex.org/W2386758691","https://openalex.org/W2743383748","https://openalex.org/W1554345071","https://openalex.org/W2898375877"],"abstract_inverted_index":{"Super":[0,54,62,94,123],"Grids":[1,124],"have":[2],"been":[3],"studied":[4],"and":[5,25,46,59,108,120],"proposed":[6,67,100],"in":[7,34,64,68,96,135],"many":[8],"countries":[9],"to":[10,36],"increase":[11],"technical":[12],"performance":[13],"of":[14,79,104,117,132,138],"high":[15,89],"voltage":[16,72,81,90],"transmission":[17],"systems.":[18],"Such":[19],"systems":[20],"must":[21],"be":[22],"efficient,":[23],"reliable,":[24],"resilient":[26],"against":[27],"weather":[28],"events":[29],"or":[30,76],"intentional":[31],"disruptive":[32],"actions":[33],"order":[35],"support":[37],"economic":[38],"development,":[39],"foster":[40],"renewable":[41],"generation,":[42],"promote":[43],"social":[44],"well-being":[45],"safeguard":[47],"national":[48],"security":[49],"interests.":[50],"This":[51,112],"paper":[52,113],"compares":[53],"Grid":[55,63,95],"proposals":[56],"for":[57,129],"China":[58,65],"the":[60,97,115,130,139],"US.":[61],"is":[66,99],"two":[69],"alternatives:":[70],"ultra-high":[71],"alternating":[73,82],"current":[74,83,92],"(UHVAC)":[75],"a":[77,102,122],"combination":[78],"extra-high":[80],"(EHVAC)":[84],"with":[85],"line":[86],"commutated":[87],"converters":[88,106],"direct":[91],"(LCC-HVDC).":[93],"US":[98],"as":[101],"mix":[103],"voltage-source":[105],"VSC-HVDC":[107],"765":[109],"kV":[110],"EHVAC.":[111],"analyses":[114],"specifics":[116],"each":[118],"architecture":[119],"proposes":[121],"topology":[125],"design":[126],"method":[127],"useful":[128],"proposition":[131],"new":[133],"topologies":[134],"other":[136],"parts":[137],"globe.":[140]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
