{"id":"https://openalex.org/W2829917116","doi":"https://doi.org/10.1109/isgt.2018.8403329","title":"On the effectiveness of data aggregation to manage network congestion in smart grid AMI","display_name":"On the effectiveness of data aggregation to manage network congestion in smart grid AMI","publication_year":2018,"publication_date":"2018-02-01","ids":{"openalex":"https://openalex.org/W2829917116","doi":"https://doi.org/10.1109/isgt.2018.8403329","mag":"2829917116"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2018.8403329","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2018.8403329","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050251316","display_name":"Uddipan Das","orcid":"https://orcid.org/0000-0002-5353-7755"},"institutions":[{"id":"https://openalex.org/I39587148","display_name":"Wichita State University","ror":"https://ror.org/00c4e7y75","country_code":"US","type":"education","lineage":["https://openalex.org/I39587148"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Uddipan Das","raw_affiliation_strings":["Department of Electrical Engineering and Computer Science, Wichita State University, KS, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Computer Science, Wichita State University, KS, USA","institution_ids":["https://openalex.org/I39587148"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013783269","display_name":"Vishnu Cherusola Dev","orcid":null},"institutions":[{"id":"https://openalex.org/I39587148","display_name":"Wichita State University","ror":"https://ror.org/00c4e7y75","country_code":"US","type":"education","lineage":["https://openalex.org/I39587148"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vishnu Cherusola Dev","raw_affiliation_strings":["Wichita State University, Wichita, KS, US"],"affiliations":[{"raw_affiliation_string":"Wichita State University, Wichita, KS, US","institution_ids":["https://openalex.org/I39587148"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008657111","display_name":"Vinod Namboodiri","orcid":"https://orcid.org/0000-0003-0705-6990"},"institutions":[{"id":"https://openalex.org/I39587148","display_name":"Wichita State University","ror":"https://ror.org/00c4e7y75","country_code":"US","type":"education","lineage":["https://openalex.org/I39587148"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vinod Namboodiri","raw_affiliation_strings":["Department of Electrical Engineering and Computer Science, Wichita State University, KS, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Computer Science, Wichita State University, KS, USA","institution_ids":["https://openalex.org/I39587148"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5050251316"],"corresponding_institution_ids":["https://openalex.org/I39587148"],"apc_list":null,"apc_paid":null,"fwci":0.1288,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.47128372,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7672141194343567},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7455801963806152},{"id":"https://openalex.org/keywords/granularity","display_name":"Granularity","score":0.6875455975532532},{"id":"https://openalex.org/keywords/data-aggregator","display_name":"Data aggregator","score":0.660737156867981},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.6090807914733887},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.5845972895622253},{"id":"https://openalex.org/keywords/volume","display_name":"Volume (thermodynamics)","score":0.5254156589508057},{"id":"https://openalex.org/keywords/aggregate","display_name":"Aggregate (composite)","score":0.520904004573822},{"id":"https://openalex.org/keywords/network-congestion","display_name":"Network congestion","score":0.5033699870109558},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.38901782035827637},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.3080599308013916},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.11761406064033508}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7672141194343567},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7455801963806152},{"id":"https://openalex.org/C177774035","wikidata":"https://www.wikidata.org/wiki/Q1246948","display_name":"Granularity","level":2,"score":0.6875455975532532},{"id":"https://openalex.org/C82578977","wikidata":"https://www.wikidata.org/wiki/Q16773055","display_name":"Data aggregator","level":3,"score":0.660737156867981},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.6090807914733887},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5845972895622253},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.5254156589508057},{"id":"https://openalex.org/C4679612","wikidata":"https://www.wikidata.org/wiki/Q866298","display_name":"Aggregate (composite)","level":2,"score":0.520904004573822},{"id":"https://openalex.org/C195563490","wikidata":"https://www.wikidata.org/wiki/Q180368","display_name":"Network congestion","level":3,"score":0.5033699870109558},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.38901782035827637},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.3080599308013916},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.11761406064033508},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2018.8403329","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2018.8403329","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.6700000166893005,"display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W2008573259","https://openalex.org/W2033662504","https://openalex.org/W2053664830","https://openalex.org/W2088084838","https://openalex.org/W2126421924","https://openalex.org/W2126644064","https://openalex.org/W2161694363","https://openalex.org/W2312015945","https://openalex.org/W6683608372"],"related_works":["https://openalex.org/W2931688134","https://openalex.org/W2377919138","https://openalex.org/W2378857091","https://openalex.org/W4256502920","https://openalex.org/W103652678","https://openalex.org/W2999756192","https://openalex.org/W4226090359","https://openalex.org/W4382701072","https://openalex.org/W2011624601","https://openalex.org/W2765119830"],"abstract_inverted_index":{"The":[0,101,115],"inclusion":[1],"of":[2,152],"various":[3],"intelligent":[4],"electronic":[5],"devices":[6],"such":[7,36,82],"as":[8,133],"smart":[9,42,157],"meters":[10],"for":[11,106],"AMI":[12,60,138],"is":[13,44,104,123],"expected":[14,70],"to":[15,33,45,58],"result":[16],"in":[17,23,41,90,126,130,137,145,150],"intermittent":[18],"or":[19],"frequent":[20],"network":[21,28,71,108,131],"congestion":[22,109,134],"communication":[24],"networks":[25],"without":[26],"additional":[27],"infrastructure":[29],"investments.":[30],"An":[31],"approach":[32,57],"deal":[34],"with":[35],"a":[37,55,91,97],"data":[38,47,61,65,99,153],"volume":[39,63],"challenge":[40],"grids":[43],"aggregate":[46],"streams":[48],"within":[49],"the":[50,69,84,88,112,120,128],"network.":[51],"This":[52],"paper":[53],"proposes":[54],"novel":[56],"manage":[59],"traffic":[62],"through":[64],"aggregation":[66,80],"that":[67,83,119],"estimates":[68],"delays":[72],"messages":[73],"would":[74],"suffer":[75],"and":[76],"dynamically":[77],"determines":[78],"an":[79],"policy":[81],"electric":[85],"utility":[86],"gets":[87],"information":[89],"more":[92],"timely":[93],"manner,":[94],"albeit":[95],"at":[96],"lower":[98],"granularity.":[100],"proposed":[102,121],"algorithm":[103,122],"evaluated":[105],"different":[107],"scenarios":[110],"using":[111],"NS-3":[113],"simulator.":[114],"simulation":[116],"results":[117],"illustrate":[118],"immensely":[124],"effective":[125],"controlling":[127],"increase":[129,136],"latencies":[132],"levels":[135],"networks.":[139],"In":[140],"addition,":[141],"it":[142],"does":[143],"well":[144],"satisfying":[146],"quality-of-service":[147],"(QoS)":[148],"requirements":[149],"terms":[151],"granularity":[154],"required":[155],"by":[156],"grid":[158],"applications.":[159]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
