{"id":"https://openalex.org/W2766872279","doi":"https://doi.org/10.1109/isgt.2017.8086063","title":"Voltage control by using capacitor banks and tap changing transformers in a renewable microgrid","display_name":"Voltage control by using capacitor banks and tap changing transformers in a renewable microgrid","publication_year":2017,"publication_date":"2017-04-01","ids":{"openalex":"https://openalex.org/W2766872279","doi":"https://doi.org/10.1109/isgt.2017.8086063","mag":"2766872279"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2017.8086063","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2017.8086063","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084078307","display_name":"Pavan Penkey","orcid":null},"institutions":[{"id":"https://openalex.org/I155093810","display_name":"University of Idaho","ror":"https://ror.org/03hbp5t65","country_code":"US","type":"education","lineage":["https://openalex.org/I155093810"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Pavan Penkey","raw_affiliation_strings":["University of Idaho, Moscow, ID, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Idaho, Moscow, ID, USA","institution_ids":["https://openalex.org/I155093810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086475083","display_name":"Husam S. Samkari","orcid":"https://orcid.org/0000-0001-7636-2591"},"institutions":[{"id":"https://openalex.org/I155093810","display_name":"University of Idaho","ror":"https://ror.org/03hbp5t65","country_code":"US","type":"education","lineage":["https://openalex.org/I155093810"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Husam Samkari","raw_affiliation_strings":["University of Idaho, Moscow, ID, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Idaho, Moscow, ID, USA","institution_ids":["https://openalex.org/I155093810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070564426","display_name":"Brian K. Johnson","orcid":"https://orcid.org/0000-0002-0747-2794"},"institutions":[{"id":"https://openalex.org/I155093810","display_name":"University of Idaho","ror":"https://ror.org/03hbp5t65","country_code":"US","type":"education","lineage":["https://openalex.org/I155093810"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Brian K. Johnson","raw_affiliation_strings":["University of Idaho, Moscow, ID, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Idaho, Moscow, ID, USA","institution_ids":["https://openalex.org/I155093810"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5006265318","display_name":"Herbert Hess","orcid":"https://orcid.org/0000-0003-1099-3854"},"institutions":[{"id":"https://openalex.org/I155093810","display_name":"University of Idaho","ror":"https://ror.org/03hbp5t65","country_code":"US","type":"education","lineage":["https://openalex.org/I155093810"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Herbert L. Hess","raw_affiliation_strings":["University of Idaho, Moscow, ID, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Idaho, Moscow, ID, USA","institution_ids":["https://openalex.org/I155093810"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I155093810"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.20112623,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.996399998664856,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9818354845046997},{"id":"https://openalex.org/keywords/tap-changer","display_name":"Tap changer","score":0.6732533574104309},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6730602979660034},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6190863251686096},{"id":"https://openalex.org/keywords/hydroelectricity","display_name":"Hydroelectricity","score":0.5490700006484985},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5478397011756897},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5397703051567078},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5139350295066833},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4516911506652832},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.417986124753952},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.37456658482551575},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3463370203971863}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9818354845046997},{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.6732533574104309},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6730602979660034},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6190863251686096},{"id":"https://openalex.org/C92311004","wikidata":"https://www.wikidata.org/wiki/Q80638","display_name":"Hydroelectricity","level":2,"score":0.5490700006484985},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5478397011756897},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5397703051567078},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5139350295066833},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4516911506652832},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.417986124753952},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37456658482551575},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3463370203971863}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2017.8086063","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2017.8086063","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5899999737739563,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W106711868","https://openalex.org/W1579670720","https://openalex.org/W1607032092","https://openalex.org/W2047273160","https://openalex.org/W2071689632","https://openalex.org/W2166712848","https://openalex.org/W2233627849","https://openalex.org/W2528351813","https://openalex.org/W2560957784","https://openalex.org/W2596520936","https://openalex.org/W4200503332","https://openalex.org/W4232284745","https://openalex.org/W4285719527","https://openalex.org/W6689524887"],"related_works":["https://openalex.org/W2948297782","https://openalex.org/W1481562555","https://openalex.org/W3000656869","https://openalex.org/W3038564840","https://openalex.org/W1494661164","https://openalex.org/W3029610439","https://openalex.org/W4252836400","https://openalex.org/W4239661224","https://openalex.org/W2153198307","https://openalex.org/W4254648297"],"abstract_inverted_index":{"This":[0,41],"paper":[1,107],"is":[2,9,73,85,108],"based":[3],"on":[4,44,119],"an":[5],"ongoing":[6],"project":[7],"that":[8],"evaluating":[10],"the":[11,23,27,45,51,54,60,64,82,111,130,135,138],"potential":[12],"for":[13,26,128],"a":[14,17,100,124],"microgrid":[15,28,55,72],"in":[16,19,53,75,93,95,137],"city":[18],"northwest":[20],"region":[21],"of":[22,48,50,59,81,99,105,113,126,133],"US.":[24],"Power":[25],"will":[29],"be":[30],"supplied":[31],"largely":[32],"from":[33],"existing":[34],"hydroelectric":[35],"generators":[36],"and":[37,62],"proposed":[38],"photovoltaic":[39],"installations.":[40],"study":[42,110],"focuses":[43],"voltage":[46,69,83,131],"profiles":[47],"all":[49,134],"buses":[52,136],"during":[56],"different":[57,97],"seasons":[58,98],"year":[61],"identifies":[63],"ways":[65],"to":[66,109],"ensure":[67],"adequate":[68],"quality.":[70],"The":[71,77,102],"modeled":[74],"Powerworld.":[76],"steady":[78],"state":[79],"behavior":[80],"profile":[84,132],"studied":[86],"over":[87],"time":[88,90],"using":[89,114],"step":[91],"simulation":[92],"Powerworld":[94],"four":[96],"year.":[101],"main":[103],"objective":[104],"this":[106],"effectiveness":[112],"shunt":[115],"capacitor":[116],"banks":[117],"or":[118,123],"load":[120],"tap":[121],"changing":[122],"combination":[125],"both":[127],"improving":[129],"microgrid.":[139]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}