{"id":"https://openalex.org/W2766714032","doi":"https://doi.org/10.1109/isgt.2017.8086054","title":"Designing proper control set-point signal for PQ inverters of isolated microgrids","display_name":"Designing proper control set-point signal for PQ inverters of isolated microgrids","publication_year":2017,"publication_date":"2017-04-01","ids":{"openalex":"https://openalex.org/W2766714032","doi":"https://doi.org/10.1109/isgt.2017.8086054","mag":"2766714032"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2017.8086054","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2017.8086054","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108647400","display_name":"F. Doost Mohammadi","orcid":null},"institutions":[{"id":"https://openalex.org/I12097938","display_name":"West Virginia University","ror":"https://ror.org/011vxgd24","country_code":"US","type":"education","lineage":["https://openalex.org/I12097938"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"F. Doost Mohammadi","raw_affiliation_strings":["Department of Electrical Engineering, Advanced Power & Electricity Research Center, West Virginia University College of Law, Morgantown, WV, US"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Advanced Power & Electricity Research Center, West Virginia University College of Law, Morgantown, WV, US","institution_ids":["https://openalex.org/I12097938"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065297128","display_name":"Hessam Keshtkar","orcid":null},"institutions":[{"id":"https://openalex.org/I12097938","display_name":"West Virginia University","ror":"https://ror.org/011vxgd24","country_code":"US","type":"education","lineage":["https://openalex.org/I12097938"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"H. Keshtkar","raw_affiliation_strings":["Department of Electrical Engineering, Advanced Power & Electricity Research Center, West Virginia University, Morgantown, WV, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Advanced Power & Electricity Research Center, West Virginia University, Morgantown, WV, USA","institution_ids":["https://openalex.org/I12097938"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089132667","display_name":"A. Feliachi","orcid":null},"institutions":[{"id":"https://openalex.org/I12097938","display_name":"West Virginia University","ror":"https://ror.org/011vxgd24","country_code":"US","type":"education","lineage":["https://openalex.org/I12097938"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"A. Feliachi","raw_affiliation_strings":["Department of Electrical Engineering, Advanced Power & Electricity Research Center, West Virginia University, Morgantown, WV, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Advanced Power & Electricity Research Center, West Virginia University, Morgantown, WV, USA","institution_ids":["https://openalex.org/I12097938"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5108647400"],"corresponding_institution_ids":["https://openalex.org/I12097938"],"apc_list":null,"apc_paid":null,"fwci":0.2012,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.54040583,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"3","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9077990055084229},{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.6128012537956238},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6048712730407715},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.5851793885231018},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.5704070329666138},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5548191070556641},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.500330924987793},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.4781126379966736},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.4545721709728241},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.44522470235824585},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4398227632045746},{"id":"https://openalex.org/keywords/set","display_name":"Set (abstract data type)","score":0.43251579999923706},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.413971483707428},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.36298131942749023},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.352590948343277},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3427008390426636},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3213786780834198},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.276258647441864},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11262857913970947},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.10737866163253784}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9077990055084229},{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.6128012537956238},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6048712730407715},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.5851793885231018},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.5704070329666138},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5548191070556641},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.500330924987793},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.4781126379966736},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4545721709728241},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44522470235824585},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4398227632045746},{"id":"https://openalex.org/C177264268","wikidata":"https://www.wikidata.org/wiki/Q1514741","display_name":"Set (abstract data type)","level":2,"score":0.43251579999923706},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.413971483707428},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.36298131942749023},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.352590948343277},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3427008390426636},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3213786780834198},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.276258647441864},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11262857913970947},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.10737866163253784},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2017.8086054","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2017.8086054","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.6600000262260437}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1504052325","https://openalex.org/W1988016866","https://openalex.org/W2049783603","https://openalex.org/W2066822226","https://openalex.org/W2074229485","https://openalex.org/W2080087186","https://openalex.org/W2089303750","https://openalex.org/W2130055347","https://openalex.org/W2151903076","https://openalex.org/W2159945777","https://openalex.org/W2165147905","https://openalex.org/W6684127454"],"related_works":["https://openalex.org/W2349700491","https://openalex.org/W3132792237","https://openalex.org/W3132497606","https://openalex.org/W4210526872","https://openalex.org/W2168694011","https://openalex.org/W2996701762","https://openalex.org/W3134658563","https://openalex.org/W2529755282","https://openalex.org/W4379525856","https://openalex.org/W2076021085"],"abstract_inverted_index":{"In":[0,73],"this":[1,74],"paper,":[2],"the":[3,29,45,59,67,93,108,137,150,165],"performance":[4,61,152],"and":[5,79,124,161],"transient":[6,166],"frequency":[7],"response":[8,167],"of":[9,17,87,92],"an":[10,130,171],"islanded":[11],"microgrid":[12,89],"with":[13],"two":[14],"different":[15,22,117],"categories":[16],"inverters":[18,86],"are":[19,26,159,168],"analyzed":[20],"when":[21],"control":[23,95,157],"set-point":[24,132],"signals":[25,158],"defined":[27],"for":[28,66,83,120,139],"Current":[30,49],"Source":[31,34,50],"Inverters.":[32],"Voltage":[33],"Inverters":[35,51],"(VSIs)":[36],"use":[37],"a":[38,88],"decentralized":[39],"droop":[40],"controller":[41],"which":[42],"helps":[43],"preserving":[44],"power-sharing":[46],"stability.":[47],"Then,":[48],"(CSI,":[52],"also":[53],"called":[54],"PQ":[55],"inverters)":[56],"will":[57],"improve":[58],"system's":[60],"by":[62,101],"providing":[63,102],"extra":[64],"capacity":[65],"system":[68],"to":[69,107,115,128],"accommodate":[70],"load":[71],"changes.":[72],"context,":[75],"defining":[76],"proper":[77],"active":[78],"reactive":[80],"power":[81,105],"set-points":[82],"CSI":[84],"(PQ)":[85],"is":[90,153],"one":[91],"necessary":[94],"designs":[96],"that":[97,149],"ensures":[98],"systems":[99,151],"integrity":[100],"more":[103],"secure":[104],"supply":[106],"loads.":[109],"The":[110,155],"study":[111],"conducted":[112],"here":[113],"tries":[114],"propose":[116],"possible":[118,145],"solution":[119],"communication":[121,140],"link":[122],"selection":[123],"definition":[125],"in":[126],"order":[127],"form":[129],"appropriate":[131],"signal.":[133],"Consequently":[134],"it":[135],"minimizes":[136],"need":[138],"links":[141],"as":[142,144],"much":[143],"while":[146],"making":[147],"sure":[148],"acceptable.":[154],"proposed":[156],"investigated":[160],"their":[162],"effects":[163],"on":[164],"demonstrated":[169],"using":[170],"11":[172],"bus":[173],"microgrid.":[174]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}