{"id":"https://openalex.org/W2765762923","doi":"https://doi.org/10.1109/isgt.2017.8086038","title":"Modular microgrid unit (MMGU) specifications for a pumped-storage application","display_name":"Modular microgrid unit (MMGU) specifications for a pumped-storage application","publication_year":2017,"publication_date":"2017-04-01","ids":{"openalex":"https://openalex.org/W2765762923","doi":"https://doi.org/10.1109/isgt.2017.8086038","mag":"2765762923"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2017.8086038","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2017.8086038","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036841047","display_name":"Bamdad Falahati","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Bamdad Falahati","raw_affiliation_strings":["Schweitzer Engineering Laboratories, Inc. (SEL)"],"affiliations":[{"raw_affiliation_string":"Schweitzer Engineering Laboratories, Inc. (SEL)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072518896","display_name":"Masood Shahverdi","orcid":"https://orcid.org/0000-0002-2794-7136"},"institutions":[{"id":"https://openalex.org/I27825529","display_name":"California State University Los Angeles","ror":"https://ror.org/0294hxs80","country_code":"US","type":"education","lineage":["https://openalex.org/I27825529"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Masood Shahverdi","raw_affiliation_strings":["Department of Electrical and Computer Engineering, California State University, Los Angeles"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, California State University, Los Angeles","institution_ids":["https://openalex.org/I27825529"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028588749","display_name":"Arash Jamehbozorg","orcid":"https://orcid.org/0000-0002-8228-5614"},"institutions":[{"id":"https://openalex.org/I27825529","display_name":"California State University Los Angeles","ror":"https://ror.org/0294hxs80","country_code":"US","type":"education","lineage":["https://openalex.org/I27825529"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Arash Jamehbozorg","raw_affiliation_strings":["Department of Electrical and Computer Engineering, California State University, Los Angeles"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, California State University, Los Angeles","institution_ids":["https://openalex.org/I27825529"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5051496098","display_name":"Mahyar Zarghami","orcid":null},"institutions":[{"id":"https://openalex.org/I43522216","display_name":"California State University, Sacramento","ror":"https://ror.org/03e26wv14","country_code":"US","type":"education","lineage":["https://openalex.org/I43522216"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Mahyar Zarghami","raw_affiliation_strings":["Department of Electrical & Electronic Engineering, California State University, Sacramento"],"affiliations":[{"raw_affiliation_string":"Department of Electrical & Electronic Engineering, California State University, Sacramento","institution_ids":["https://openalex.org/I43522216"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5036841047"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.16662248,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"2","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.959833025932312},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.8168075680732727},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.7650234699249268},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5402981042861938},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.5035423636436462},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.5008695125579834},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4949430823326111},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.49040985107421875},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.45004332065582275},{"id":"https://openalex.org/keywords/unit","display_name":"Unit (ring theory)","score":0.4450409710407257},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.4299502968788147},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4270623028278351},{"id":"https://openalex.org/keywords/hydropower","display_name":"Hydropower","score":0.42589110136032104},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3915104269981384},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3861920237541199},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.34417301416397095},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.25997623801231384},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.22852182388305664},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.16906356811523438},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.08111509680747986}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.959833025932312},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.8168075680732727},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.7650234699249268},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5402981042861938},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.5035423636436462},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5008695125579834},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4949430823326111},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.49040985107421875},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.45004332065582275},{"id":"https://openalex.org/C122637931","wikidata":"https://www.wikidata.org/wiki/Q118084","display_name":"Unit (ring theory)","level":2,"score":0.4450409710407257},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.4299502968788147},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4270623028278351},{"id":"https://openalex.org/C40675005","wikidata":"https://www.wikidata.org/wiki/Q170196","display_name":"Hydropower","level":2,"score":0.42589110136032104},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3915104269981384},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3861920237541199},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34417301416397095},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25997623801231384},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.22852182388305664},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.16906356811523438},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.08111509680747986},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C145420912","wikidata":"https://www.wikidata.org/wiki/Q853077","display_name":"Mathematics education","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2017.8086038","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2017.8086038","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Power &amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W81336525","https://openalex.org/W561212068","https://openalex.org/W1973449155","https://openalex.org/W2000400356","https://openalex.org/W2042584576","https://openalex.org/W2072233432","https://openalex.org/W2142364586","https://openalex.org/W2322460481","https://openalex.org/W2327321010","https://openalex.org/W2342839914","https://openalex.org/W2556480028","https://openalex.org/W2565912474","https://openalex.org/W2744885780"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W4308700935","https://openalex.org/W4210780382","https://openalex.org/W2356033827","https://openalex.org/W2391138633","https://openalex.org/W3037384208","https://openalex.org/W1600945217","https://openalex.org/W1932401759","https://openalex.org/W2001580136"],"abstract_inverted_index":{"A":[0,63],"modular":[1],"microgrid":[2,8],"unit":[3,51],"(MMGU)":[4],"is":[5,14,28,59,70,130],"a":[6,53,93,119],"packaged":[7],"that":[9],"can":[10,31],"work":[11],"autonomously":[12],"but":[13],"also":[15],"capable":[16],"of":[17,56,81,89,99,110,127],"connecting":[18],"to":[19,22,71,77,107],"other":[20],"MMGUs":[21],"form":[23],"an":[24,68,90],"expandable":[25],"microgrid.":[26],"It":[27],"flexible":[29],"and":[30,103,124],"be":[32],"implemented":[33],"with":[34,48],"different":[35],"resources,":[36],"such":[37],"as":[38],"hydropower":[39],"or":[40],"wind.":[41],"An":[42],"MMGU's":[43],"power":[44],"electronic":[45],"interface":[46],"accompanied":[47],"battery":[49],"storage":[50],"provides":[52],"high":[54],"level":[55],"stability,":[57],"which":[58],"critical":[60],"in":[61,92],"microgrids.":[62],"key":[64],"factor":[65],"when":[66],"implementing":[67],"MMGU":[69,74,91,100,115],"determine":[72],"appropriate":[73],"component":[75,116],"ratings":[76,117],"match":[78],"physical":[79],"characteristics":[80],"available":[82],"resources.":[83],"This":[84],"paper":[85],"discusses":[86],"the":[87,125,128],"application":[88],"pumped-storage":[94],"unit.":[95],"The":[96],"main":[97],"components":[98],"are":[101,105,122],"introduced":[102],"equations":[104],"presented":[106],"find":[108],"rating":[109],"these":[111],"components.":[112],"Then,":[113],"typical":[114],"for":[118],"250-kW":[120],"system":[121],"calculated":[123],"feasibility":[126],"design":[129],"assessed.":[131]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
