{"id":"https://openalex.org/W2044113758","doi":"https://doi.org/10.1109/isgt.2014.6816419","title":"Quantifying the impact of battery constraints on microgrid operation using optimal control","display_name":"Quantifying the impact of battery constraints on microgrid operation using optimal control","publication_year":2014,"publication_date":"2014-02-01","ids":{"openalex":"https://openalex.org/W2044113758","doi":"https://doi.org/10.1109/isgt.2014.6816419","mag":"2044113758"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2014.6816419","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2014.6816419","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ISGT 2014","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102087278","display_name":"Rakesh M. Patil","orcid":null},"institutions":[{"id":"https://openalex.org/I118347220","display_name":"NEC (Japan)","ror":"https://ror.org/04jndar25","country_code":"JP","type":"company","lineage":["https://openalex.org/I118347220"]},{"id":"https://openalex.org/I4210107353","display_name":"NEC (United States)","ror":"https://ror.org/01v791m31","country_code":"US","type":"company","lineage":["https://openalex.org/I118347220","https://openalex.org/I4210107353"]}],"countries":["JP","US"],"is_corresponding":true,"raw_author_name":"Rakesh Patil","raw_affiliation_strings":["Energy Management Department, NEC Labs America","Energy Management Department at NEC Labs America, USA"],"affiliations":[{"raw_affiliation_string":"Energy Management Department, NEC Labs America","institution_ids":["https://openalex.org/I118347220"]},{"raw_affiliation_string":"Energy Management Department at NEC Labs America, USA","institution_ids":["https://openalex.org/I4210107353"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102736348","display_name":"Ratnesh Sharma","orcid":"https://orcid.org/0000-0002-9139-2120"},"institutions":[{"id":"https://openalex.org/I4210107353","display_name":"NEC (United States)","ror":"https://ror.org/01v791m31","country_code":"US","type":"company","lineage":["https://openalex.org/I118347220","https://openalex.org/I4210107353"]},{"id":"https://openalex.org/I118347220","display_name":"NEC (Japan)","ror":"https://ror.org/04jndar25","country_code":"JP","type":"company","lineage":["https://openalex.org/I118347220"]}],"countries":["JP","US"],"is_corresponding":false,"raw_author_name":"Ratnesh Sharma","raw_affiliation_strings":["Energy Management Department, NEC Labs America","Energy Management Department at NEC Labs America, USA"],"affiliations":[{"raw_affiliation_string":"Energy Management Department, NEC Labs America","institution_ids":["https://openalex.org/I118347220"]},{"raw_affiliation_string":"Energy Management Department at NEC Labs America, USA","institution_ids":["https://openalex.org/I4210107353"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5102087278"],"corresponding_institution_ids":["https://openalex.org/I118347220","https://openalex.org/I4210107353"],"apc_list":null,"apc_paid":null,"fwci":0.77712735,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.7794622,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9613254070281982},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.7369668483734131},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6367469429969788},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5990155935287476},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.5337992906570435},{"id":"https://openalex.org/keywords/constraint","display_name":"Constraint (computer-aided design)","score":0.5232371687889099},{"id":"https://openalex.org/keywords/optimal-control","display_name":"Optimal control","score":0.49604544043540955},{"id":"https://openalex.org/keywords/dynamic-programming","display_name":"Dynamic programming","score":0.4698352515697479},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43291378021240234},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.38264167308807373},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.36177510023117065},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3179914355278015},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21517223119735718},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10408329963684082},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.07603853940963745}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9613254070281982},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.7369668483734131},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6367469429969788},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5990155935287476},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.5337992906570435},{"id":"https://openalex.org/C2776036281","wikidata":"https://www.wikidata.org/wiki/Q48769818","display_name":"Constraint (computer-aided design)","level":2,"score":0.5232371687889099},{"id":"https://openalex.org/C91575142","wikidata":"https://www.wikidata.org/wiki/Q1971426","display_name":"Optimal control","level":2,"score":0.49604544043540955},{"id":"https://openalex.org/C37404715","wikidata":"https://www.wikidata.org/wiki/Q380679","display_name":"Dynamic programming","level":2,"score":0.4698352515697479},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43291378021240234},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.38264167308807373},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.36177510023117065},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3179914355278015},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21517223119735718},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10408329963684082},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.07603853940963745},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2014.6816419","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2014.6816419","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ISGT 2014","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8899999856948853}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W133442417","https://openalex.org/W2018637736","https://openalex.org/W2029515813","https://openalex.org/W2041075675","https://openalex.org/W2042799003","https://openalex.org/W2058626062","https://openalex.org/W2065132570","https://openalex.org/W2069956790","https://openalex.org/W2089758604","https://openalex.org/W2099154097","https://openalex.org/W2127761430","https://openalex.org/W2148576984","https://openalex.org/W6679348305"],"related_works":["https://openalex.org/W1932159282","https://openalex.org/W4285537323","https://openalex.org/W2379312070","https://openalex.org/W2136173754","https://openalex.org/W2110050003","https://openalex.org/W2953025626","https://openalex.org/W2499081552","https://openalex.org/W2366053282","https://openalex.org/W2128788708","https://openalex.org/W2097061373"],"abstract_inverted_index":{"This":[0],"paper":[1,129],"presents":[2],"an":[3,69,105],"approach":[4,133],"to":[5,89,110,134],"quantify":[6],"the":[7,14,97,112,136,141,169],"impact":[8,95,113,137],"of":[9,18,26,114,122,127,138,143,165],"critical":[10],"battery":[11,80,152,155],"constraints":[12,115,139,150],"on":[13,96,116,151],"optimal":[15,39,106,108,163],"operating":[16],"performance":[17],"a":[19,23,34],"grid-tied":[20],"microgrid.":[21],"For":[22,58],"chosen":[24],"set":[25],"solar":[27],"power,":[28],"load":[29],"and":[30,67,140,154],"grid":[31,44,61,85,117],"cost":[32,164],"conditions,":[33],"dynamic":[35],"programming":[36],"(DP)":[37],"based":[38],"control":[40],"algorithm":[41],"minimizes":[42],"imported":[43,60],"energy":[45,62,86],"costs.":[46],"The":[47,82,124],"microgrid":[48,166],"operation":[49,167],"is":[50],"optimized":[51],"for":[52,168],"different":[53],"constraint":[54,72,92],"values":[55],"using":[56],"DP.":[57],"example,":[59],"costs":[63,87,118],"are":[64,130],"minimized":[65],"with":[66],"without":[68],"important":[70],"practical":[71],"such":[73],"as":[74],"constant":[75,77],"current":[76],"voltage":[78],"(CCCV)":[79],"charging.":[81],"increase":[83,161],"in":[84,159,162,172],"due":[88],"this":[90,101,128],"necessary":[91],"quantifies":[93],"its":[94],"microgrid's":[98],"performance.":[99],"In":[100],"manner,":[102],"we":[103],"present":[104],"vs.":[107],"comparison":[109],"capture":[111],"or":[119],"other":[120],"objectives":[121],"interest.":[123],"unique":[125],"contributions":[126],"our":[131,144,173],"rigorous":[132],"evaluate":[135],"value":[142],"results.":[145],"It":[146],"was":[147],"observed":[148],"that":[149],"charging":[153],"capacity":[156],"can":[157],"result":[158],"significant":[160],"conditions":[170],"assumed":[171],"study.":[174]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2016,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
