{"id":"https://openalex.org/W2082716752","doi":"https://doi.org/10.1109/isgt.2012.6175768","title":"Real-time power system analysis and security monitoring by WAMPAC systems","display_name":"Real-time power system analysis and security monitoring by WAMPAC systems","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2082716752","doi":"https://doi.org/10.1109/isgt.2012.6175768","mag":"2082716752"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2012.6175768","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2012.6175768","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE PES Innovative Smart Grid Technologies (ISGT)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5007745263","display_name":"Vahid Salehi","orcid":"https://orcid.org/0000-0002-7710-9085"},"institutions":[{"id":"https://openalex.org/I19700959","display_name":"Florida International University","ror":"https://ror.org/02gz6gg07","country_code":"US","type":"education","lineage":["https://openalex.org/I19700959"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vahid Salehi","raw_affiliation_strings":["Electrical Engineering Department, Florida International University, Miami, 33174 USA","Electrical Engineering Department, Florida International University, Miami, 33174, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174 USA","institution_ids":["https://openalex.org/I19700959"]},{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174, USA","institution_ids":["https://openalex.org/I19700959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039199745","display_name":"Ali Mazloomzadeh","orcid":null},"institutions":[{"id":"https://openalex.org/I19700959","display_name":"Florida International University","ror":"https://ror.org/02gz6gg07","country_code":"US","type":"education","lineage":["https://openalex.org/I19700959"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ali Mazloomzadeh","raw_affiliation_strings":["Electrical Engineering Department, Florida International University, Miami, 33174 USA","Electrical Engineering Department, Florida International University, Miami, 33174, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174 USA","institution_ids":["https://openalex.org/I19700959"]},{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174, USA","institution_ids":["https://openalex.org/I19700959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103006359","display_name":"Juan F. G\u00f3mez Fern\u00e1ndez","orcid":"https://orcid.org/0000-0003-3995-5376"},"institutions":[{"id":"https://openalex.org/I19700959","display_name":"Florida International University","ror":"https://ror.org/02gz6gg07","country_code":"US","type":"education","lineage":["https://openalex.org/I19700959"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Juan F. Fernandez","raw_affiliation_strings":["Electrical Engineering Department, Florida International University, Miami, 33174 USA","Electrical Engineering Department, Florida International University, Miami, 33174, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174 USA","institution_ids":["https://openalex.org/I19700959"]},{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174, USA","institution_ids":["https://openalex.org/I19700959"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035179934","display_name":"Osama A. Mohammed","orcid":"https://orcid.org/0000-0002-2586-4046"},"institutions":[{"id":"https://openalex.org/I19700959","display_name":"Florida International University","ror":"https://ror.org/02gz6gg07","country_code":"US","type":"education","lineage":["https://openalex.org/I19700959"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Osama A. Mohammed","raw_affiliation_strings":["Electrical Engineering Department, Florida International University, Miami, 33174 USA","Electrical Engineering Department, Florida International University, Miami, 33174, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174 USA","institution_ids":["https://openalex.org/I19700959"]},{"raw_affiliation_string":"Electrical Engineering Department, Florida International University, Miami, 33174, USA","institution_ids":["https://openalex.org/I19700959"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I19700959"],"apc_list":null,"apc_paid":null,"fwci":3.2985,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.93115299,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6756118535995483},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6355920433998108},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.5647547245025635},{"id":"https://openalex.org/keywords/security-analysis","display_name":"Security analysis","score":0.526498019695282},{"id":"https://openalex.org/keywords/system-monitoring","display_name":"System monitoring","score":0.5062857866287231},{"id":"https://openalex.org/keywords/principal","display_name":"Principal (computer security)","score":0.4759240448474884},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.45322638750076294},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.42613500356674194},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.4207211434841156},{"id":"https://openalex.org/keywords/security-controls","display_name":"Security controls","score":0.41156163811683655},{"id":"https://openalex.org/keywords/real-time-operating-system","display_name":"Real-time operating system","score":0.4103918671607971},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.38065576553344727},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3582155704498291},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.35659152269363403},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.28358739614486694},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.25520044565200806},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.14513903856277466}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6756118535995483},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6355920433998108},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.5647547245025635},{"id":"https://openalex.org/C38369872","wikidata":"https://www.wikidata.org/wiki/Q7445009","display_name":"Security analysis","level":2,"score":0.526498019695282},{"id":"https://openalex.org/C200749887","wikidata":"https://www.wikidata.org/wiki/Q1165574","display_name":"System monitoring","level":2,"score":0.5062857866287231},{"id":"https://openalex.org/C144559511","wikidata":"https://www.wikidata.org/wiki/Q2986279","display_name":"Principal (computer security)","level":2,"score":0.4759240448474884},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.45322638750076294},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.42613500356674194},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4207211434841156},{"id":"https://openalex.org/C178148461","wikidata":"https://www.wikidata.org/wiki/Q1632136","display_name":"Security controls","level":3,"score":0.41156163811683655},{"id":"https://openalex.org/C28472234","wikidata":"https://www.wikidata.org/wiki/Q213666","display_name":"Real-time operating system","level":2,"score":0.4103918671607971},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.38065576553344727},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3582155704498291},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.35659152269363403},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.28358739614486694},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25520044565200806},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.14513903856277466},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2012.6175768","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2012.6175768","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE PES Innovative Smart Grid Technologies (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1964108382","https://openalex.org/W1977014207","https://openalex.org/W1990297769","https://openalex.org/W1997081029","https://openalex.org/W1997706009","https://openalex.org/W2003443331","https://openalex.org/W2025412567","https://openalex.org/W2056859172","https://openalex.org/W2074802243","https://openalex.org/W2075276111","https://openalex.org/W2081078577","https://openalex.org/W2107163632","https://openalex.org/W2148213050","https://openalex.org/W2150490642","https://openalex.org/W2151109389","https://openalex.org/W2159393016"],"related_works":["https://openalex.org/W236190221","https://openalex.org/W2379779959","https://openalex.org/W2333822231","https://openalex.org/W2394141650","https://openalex.org/W2368173817","https://openalex.org/W2358770178","https://openalex.org/W2349211712","https://openalex.org/W1669532953","https://openalex.org/W4377232819","https://openalex.org/W2405731891"],"abstract_inverted_index":{"The":[0,29,57,77],"outline":[1],"of":[2,22,32,104,164],"this":[3],"paper":[4,107],"is":[5,19,41,75,80,171],"to":[6,26,42,64,82,101,114,122,160],"implement":[7,115],"real-time":[8,62,140,151],"analysis":[9,118],"and":[10,37,68,90,112,126,136,156],"security":[11,125,162],"monitoring":[12,135,163],"in":[13,92,120,139,167],"the":[14,20,23,49,110,130,146],"smart":[15],"power":[16,24,165],"system.":[17],"Security":[18],"ability":[21],"system":[25,40,46,50,60,66,79,117,124,138,166,178],"withstand":[27,53],"contingencies.":[28],"principal":[30],"role":[31],"Wide":[33],"Area":[34],"Monitoring,":[35],"Protection":[36],"Control":[38],"(WAMPAC)":[39],"maintain":[43],"a":[44,93],"secure":[45],"state,":[47],"i.e.":[48],"that":[51],"can":[52],"each":[54],"specified":[55],"contingency.":[56],"advanced":[58],"WAM":[59],"uses":[61],"measurements":[63],"monitor":[65,123],"status":[67],"hence":[69],"determines":[70],"whether":[71],"or":[72],"not":[73],"it":[74],"secure.":[76],"WAMPAC":[78],"used":[81],"deploy":[83],"proper":[84,161],"control":[85,103],"actions":[86],"on":[87],"load,":[88],"transmission":[89],"generation":[91],"wide":[94,168],"time":[95],"frame":[96],"from":[97],"fast":[98],"protection":[99],"systems":[100],"slower":[102],"generators.":[105],"This":[106],"also":[108],"explores":[109],"challenges":[111],"opportunities":[113],"online":[116,147],"capability":[119],"order":[121],"stability":[127],"indices.":[128],"Therefore,":[129],"implemented":[131],"hardware/software":[132],"setup":[133],"for":[134,173],"analyzing":[137],"format":[141],"will":[142],"be":[143],"presented":[144],"by":[145],"results":[148,158],"available":[149],"with":[150],"software.":[152],"Online":[153],"load":[154],"flow":[155],"contingency":[157],"aim":[159],"area":[169],"which":[170],"useful":[172],"most":[174],"application":[175],"such":[176],"as":[177],"remedial":[179],"actions.":[180]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2018,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
