{"id":"https://openalex.org/W2053847800","doi":"https://doi.org/10.1109/isgt.2012.6175702","title":"Model-based automated reconfiguration for fault isolation and restoration","display_name":"Model-based automated reconfiguration for fault isolation and restoration","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2053847800","doi":"https://doi.org/10.1109/isgt.2012.6175702","mag":"2053847800"},"language":"en","primary_location":{"id":"doi:10.1109/isgt.2012.6175702","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2012.6175702","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE PES Innovative Smart Grid Technologies (ISGT)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103054231","display_name":"Kevin Russell","orcid":"https://orcid.org/0000-0002-0722-8839"},"institutions":[{"id":"https://openalex.org/I4210127824","display_name":"Electrical Distribution Design (United States)","ror":"https://ror.org/03jgkwp62","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127824"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"K. J. Russell","raw_affiliation_strings":["Electrical Distribution Design, Inc., Blacksburg, VA, USA","Electrical Distribution Design, Inc., Blacksburg, VA 24060 USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Distribution Design, Inc., Blacksburg, VA, USA","institution_ids":["https://openalex.org/I4210127824"]},{"raw_affiliation_string":"Electrical Distribution Design, Inc., Blacksburg, VA 24060 USA","institution_ids":["https://openalex.org/I4210127824"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018147842","display_name":"Robert Broadwater","orcid":"https://orcid.org/0000-0001-7862-6423"},"institutions":[{"id":"https://openalex.org/I859038795","display_name":"Virginia Tech","ror":"https://ror.org/02smfhw86","country_code":"US","type":"education","lineage":["https://openalex.org/I859038795"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"R. P. Broadwater","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA, USA","Department of Electrical and Computer Engineering, Virginia Tech Blacksburg, 24061, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA, USA","institution_ids":["https://openalex.org/I859038795"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Virginia Tech Blacksburg, 24061, USA","institution_ids":["https://openalex.org/I859038795"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.1882,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.86254044,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10714","display_name":"Software-Defined Networks and 5G","score":0.9882000088691711,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.8647307753562927},{"id":"https://openalex.org/keywords/scada","display_name":"SCADA","score":0.80907142162323},{"id":"https://openalex.org/keywords/recloser","display_name":"Recloser","score":0.7058390378952026},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6456137895584106},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.6429484486579895},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.6298417448997498},{"id":"https://openalex.org/keywords/supervisory-control","display_name":"Supervisory control","score":0.5731232166290283},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5132288932800293},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4931878447532654},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4811623990535736},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.48103052377700806},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4269055128097534},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.38747575879096985},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3793831169605255},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3038177490234375},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27171871066093445},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.1446554958820343}],"concepts":[{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.8647307753562927},{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.80907142162323},{"id":"https://openalex.org/C31712484","wikidata":"https://www.wikidata.org/wiki/Q618740","display_name":"Recloser","level":3,"score":0.7058390378952026},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6456137895584106},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.6429484486579895},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.6298417448997498},{"id":"https://openalex.org/C92991967","wikidata":"https://www.wikidata.org/wiki/Q7644329","display_name":"Supervisory control","level":3,"score":0.5731232166290283},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5132288932800293},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4931878447532654},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4811623990535736},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.48103052377700806},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4269055128097534},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.38747575879096985},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3793831169605255},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3038177490234375},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27171871066093445},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.1446554958820343},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt.2012.6175702","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt.2012.6175702","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE PES Innovative Smart Grid Technologies (ISGT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1589951597","https://openalex.org/W2002170411","https://openalex.org/W2005078788","https://openalex.org/W2068511543","https://openalex.org/W2097104766","https://openalex.org/W2115676005","https://openalex.org/W2136912320","https://openalex.org/W2154085914","https://openalex.org/W2290426975","https://openalex.org/W2986348978"],"related_works":["https://openalex.org/W2981823288","https://openalex.org/W2020898970","https://openalex.org/W4234406316","https://openalex.org/W2353372523","https://openalex.org/W3201734049","https://openalex.org/W2534387874","https://openalex.org/W2040933081","https://openalex.org/W308697330","https://openalex.org/W2943911154","https://openalex.org/W2619521171"],"abstract_inverted_index":{"This":[0],"paper":[1,97],"presents":[2],"a":[3,31,57],"new":[4],"concept":[5],"for":[6],"automated":[7],"reconfiguration":[8,59,110,118],"control":[9,36],"that":[10],"is":[11],"based":[12,33],"on":[13],"past":[14],"model-based":[15,58,103],"system":[16,22],"analysis,":[17],"load":[18],"modeling":[19],"and":[20,26,51,61,73,79,89,112,115,121],"integrated":[21],"recovery":[23,87],"analysis":[24,104,113],"research":[25],"development.":[27],"The":[28,96],"approach":[29],"uses":[30],"software":[32],"supervisory":[34],"level":[35,42],"application":[37],"that:":[38],"(1)":[39],"Monitors":[40],"device":[41,45],"distribution":[43],"protection":[44],"operation,":[46],"(2)":[47],"Generates":[48],"isolation":[49],"refinement":[50],"restoration":[52],"switch":[53,65],"operation":[54,66],"lists":[55],"using":[56],"algorithm,":[60,114],"(3)":[62],"Uses":[63],"the":[64,91,102,109],"list":[67],"to":[68,83,107],"remotely":[69],"operate":[70],"switches,":[71],"reclosers":[72],"circuit":[74],"breakers":[75],"through":[76],"Supervisory":[77],"Control":[78],"Data":[80],"Acquisition":[81],"(SCADA)":[82],"speed":[84],"up":[85],"fault":[86],"actions":[88],"reduce":[90],"size":[92],"of":[93,101],"outaged":[94],"areas.":[95],"provides":[98],"an":[99],"overview":[100],"concepts":[105],"used":[106],"implement":[108],"controller":[111],"also":[116],"discusses":[117],"algorithm":[119],"design":[120],"operation.":[122]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
