{"id":"https://openalex.org/W4310174170","doi":"https://doi.org/10.1109/isgt-europe54678.2022.9960693","title":"Relay Protection in Microgrids: Settings and Sensitivity in Presence of IBDERs","display_name":"Relay Protection in Microgrids: Settings and Sensitivity in Presence of IBDERs","publication_year":2022,"publication_date":"2022-10-10","ids":{"openalex":"https://openalex.org/W4310174170","doi":"https://doi.org/10.1109/isgt-europe54678.2022.9960693"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-europe54678.2022.9960693","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe54678.2022.9960693","pdf_url":null,"source":{"id":"https://openalex.org/S4363608096","display_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055619298","display_name":"Nikola Simi\u0107","orcid":null},"institutions":[{"id":"https://openalex.org/I170726198","display_name":"University of Novi Sad","ror":"https://ror.org/00xa57a59","country_code":"RS","type":"education","lineage":["https://openalex.org/I170726198"]}],"countries":["RS"],"is_corresponding":false,"raw_author_name":"Nikola Simic","raw_affiliation_strings":["University of Novi Sad,Faculty of Technical Sciences,Department of Power, Electronics and Telecommunication Engineering,Novi Sad,Serbia","Department of Power, Electronics and Telecommunication Engineering, Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Novi Sad,Faculty of Technical Sciences,Department of Power, Electronics and Telecommunication Engineering,Novi Sad,Serbia","institution_ids":["https://openalex.org/I170726198"]},{"raw_affiliation_string":"Department of Power, Electronics and Telecommunication Engineering, Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia","institution_ids":["https://openalex.org/I170726198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006299772","display_name":"Luk\u0430 Str\u0435z\u043eski","orcid":"https://orcid.org/0000-0003-0109-4320"},"institutions":[{"id":"https://openalex.org/I170726198","display_name":"University of Novi Sad","ror":"https://ror.org/00xa57a59","country_code":"RS","type":"education","lineage":["https://openalex.org/I170726198"]}],"countries":["RS"],"is_corresponding":false,"raw_author_name":"Luka Strezoski","raw_affiliation_strings":["University of Novi Sad,Faculty of Technical Sciences,Department of Power, Electronics and Telecommunication Engineering,Novi Sad,Serbia","Department of Power, Electronics and Telecommunication Engineering, Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Novi Sad,Faculty of Technical Sciences,Department of Power, Electronics and Telecommunication Engineering,Novi Sad,Serbia","institution_ids":["https://openalex.org/I170726198"]},{"raw_affiliation_string":"Department of Power, Electronics and Telecommunication Engineering, Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia","institution_ids":["https://openalex.org/I170726198"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044904850","display_name":"Radenko Milicevic","orcid":null},"institutions":[{"id":"https://openalex.org/I170726198","display_name":"University of Novi Sad","ror":"https://ror.org/00xa57a59","country_code":"RS","type":"education","lineage":["https://openalex.org/I170726198"]}],"countries":["RS"],"is_corresponding":false,"raw_author_name":"Radenko Milicevic","raw_affiliation_strings":["ALBO Energy,Novi Sad,Serbia","ALBO Energy, Novi Sad, Serbia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ALBO Energy,Novi Sad,Serbia","institution_ids":["https://openalex.org/I170726198"]},{"raw_affiliation_string":"ALBO Energy, Novi Sad, Serbia","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I170726198"],"apc_list":null,"apc_paid":null,"fwci":1.0522,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.73676796,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.987500011920929,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.7881304621696472},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.7847684621810913},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.6445452570915222},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5066733956336975},{"id":"https://openalex.org/keywords/digital-protective-relay","display_name":"Digital protective relay","score":0.45513805747032166},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3239676058292389},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17049962282180786},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09091377258300781},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.07103177905082703}],"concepts":[{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.7881304621696472},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7847684621810913},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.6445452570915222},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5066733956336975},{"id":"https://openalex.org/C183912175","wikidata":"https://www.wikidata.org/wiki/Q4293157","display_name":"Digital protective relay","level":5,"score":0.45513805747032166},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3239676058292389},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17049962282180786},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09091377258300781},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.07103177905082703},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-europe54678.2022.9960693","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe54678.2022.9960693","pdf_url":null,"source":{"id":"https://openalex.org/S4363608096","display_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1759197186","https://openalex.org/W2120072243","https://openalex.org/W2526060323","https://openalex.org/W2530820612","https://openalex.org/W2801133752","https://openalex.org/W2806685451","https://openalex.org/W2975895496","https://openalex.org/W2983044838","https://openalex.org/W3156774506","https://openalex.org/W3204953663"],"related_works":["https://openalex.org/W3204341683","https://openalex.org/W2139098384","https://openalex.org/W2377271149","https://openalex.org/W2381445233","https://openalex.org/W2110573863","https://openalex.org/W4387011889","https://openalex.org/W1605816402","https://openalex.org/W2010101189","https://openalex.org/W2141358323","https://openalex.org/W2546850010"],"abstract_inverted_index":{"Modern":[0],"power":[1,69,98],"systems":[2],"are":[3,12,76,92,106,204],"passing":[4],"through":[5],"the":[6,18,57,95,116,120,137,142,147,153,181,207],"most":[7,73,138,182],"significant":[8,139],"change":[9,15],"after":[10],"they":[11,91],"built.":[13],"This":[14],"leads":[16],"to":[17,68,94,103,122,141],"faster":[19],"achievement":[20,58],"of":[21,31,35,49,52,59,159,176,195,202],"three":[22],"key":[23],"goals:":[24],"decarbonization,":[25],"digitalization,":[26],"and":[27,54,81,86,164,190],"decentralization.":[28],"The":[29,43,193],"emergence":[30],"an":[32],"increasing":[33],"number":[34],"distributed":[36],"energy":[37],"resources":[38],"(DERs)":[39],"supports":[40],"this":[41,196],"process.":[42],"microgrid,":[44],"as":[45],"a":[46],"new":[47,127],"concept":[48],"local":[50],"connection":[51],"consumptions":[53],"DERs,":[55],"enables":[56],"these":[60],"goals":[61],"but":[62],"also":[63,107],"brings":[64],"many":[65],"challenges":[66],"posed":[67],"system":[70],"engineers.":[71],"Since":[72],"modern":[74,183],"DERs":[75,177],"entirely":[77,108],"different":[78,109],"in":[79,151,171,198,206],"nature":[80],"operation":[82,124,135,203],"from":[83,110,119,146],"traditional":[84],"synchronous":[85],"asynchronous":[87],"machines,":[88],"primarily":[89],"because":[90],"connected":[93],"grid":[96],"via":[97],"electronics":[99],"devices,":[100],"their":[101],"contributions":[102],"fault":[104,143,155],"current":[105,144,156],"conventional":[111],"sources\u2019":[112],"contributions.":[113,161],"In":[114,133],"addition,":[115],"microgrid":[117],"transition":[118],"grid-connected":[121,134],"islanded":[123],"mode":[125],"creates":[126],"circumstances":[128],"that":[129],"must":[130],"be":[131],"analyzed.":[132],"mode,":[136],"contribution":[140],"comes":[145],"utility":[148],"network,":[149],"while":[150],"islanded,":[152],"complete":[154],"consists":[157],"only":[158],"DER":[160],"Short-circuit":[162],"analysis":[163,197],"its":[165],"impact":[166],"on":[167,180],"relay":[168,186],"protection":[169,187],"settings":[170],"microgrids":[172],"with":[173],"high":[174],"penetration":[175],"were":[178],"performed":[179],"\"Hardware-in-the-loop\"":[184],"setup,":[185],"testing":[188],"device,":[189],"commercial":[191],"relays.":[192],"results":[194],"both":[199],"microgrid\u2019s":[200],"modes":[201],"presented":[205],"paper.":[208]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
