{"id":"https://openalex.org/W4310145833","doi":"https://doi.org/10.1109/isgt-europe54678.2022.9960521","title":"Measurement and Operation Based Condition Monitoring Methodology for High Voltage Circuit Breakers","display_name":"Measurement and Operation Based Condition Monitoring Methodology for High Voltage Circuit Breakers","publication_year":2022,"publication_date":"2022-10-10","ids":{"openalex":"https://openalex.org/W4310145833","doi":"https://doi.org/10.1109/isgt-europe54678.2022.9960521"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-europe54678.2022.9960521","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe54678.2022.9960521","pdf_url":null,"source":{"id":"https://openalex.org/S4363608096","display_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5065837184","display_name":"Sajjad Asefi","orcid":"https://orcid.org/0000-0001-8308-9677"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":true,"raw_author_name":"Sajjad Asefi","raw_affiliation_strings":["Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","institution_ids":["https://openalex.org/I111112146"]},{"raw_affiliation_string":"Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037417113","display_name":"Guido Andreesen","orcid":null},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Guido Andreesen","raw_affiliation_strings":["Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","institution_ids":["https://openalex.org/I111112146"]},{"raw_affiliation_string":"Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000337906","display_name":"Madis Leinakse","orcid":"https://orcid.org/0000-0003-0364-5405"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Madis Leinakse","raw_affiliation_strings":["Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","institution_ids":["https://openalex.org/I111112146"]},{"raw_affiliation_string":"Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049364962","display_name":"Jako Kilter","orcid":"https://orcid.org/0000-0003-4985-857X"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Jako Kilter","raw_affiliation_strings":["Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Tallinn University of Technology,Department of Electrical Power Engineering and Mechatronics,Tallinn,Estonia","institution_ids":["https://openalex.org/I111112146"]},{"raw_affiliation_string":"Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055996289","display_name":"Tauri Kalmet","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tauri Kalmet","raw_affiliation_strings":["Elering AS,Grid Maintenance Department,Tallinn,Estonia","Grid Maintenance Department, Elering AS, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Elering AS,Grid Maintenance Department,Tallinn,Estonia","institution_ids":[]},{"raw_affiliation_string":"Grid Maintenance Department, Elering AS, Tallinn, Estonia","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084048523","display_name":"Henri Manninen","orcid":"https://orcid.org/0000-0003-4791-1744"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Henri Manninen","raw_affiliation_strings":["Elering AS,Grid Maintenance Department,Tallinn,Estonia","Grid Maintenance Department, Elering AS, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Elering AS,Grid Maintenance Department,Tallinn,Estonia","institution_ids":[]},{"raw_affiliation_string":"Grid Maintenance Department, Elering AS, Tallinn, Estonia","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5051178863","display_name":"Mart Landsberg","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mart Landsberg","raw_affiliation_strings":["Elering AS,Grid Maintenance Department,Tallinn,Estonia","Grid Maintenance Department, Elering AS, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Elering AS,Grid Maintenance Department,Tallinn,Estonia","institution_ids":[]},{"raw_affiliation_string":"Grid Maintenance Department, Elering AS, Tallinn, Estonia","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5065837184"],"corresponding_institution_ids":["https://openalex.org/I111112146"],"apc_list":null,"apc_paid":null,"fwci":1.2402,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.9670987,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.7856786251068115},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7816324234008789},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.6556950211524963},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.5449104309082031},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5022435188293457},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.49495190382003784},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.46610507369041443},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46542805433273315},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"Predictive maintenance","score":0.4621179401874542},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4316040873527527},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3630225956439972},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.32129591703414917},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.252517431974411}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.7856786251068115},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7816324234008789},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6556950211524963},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.5449104309082031},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5022435188293457},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.49495190382003784},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.46610507369041443},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46542805433273315},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.4621179401874542},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4316040873527527},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3630225956439972},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32129591703414917},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.252517431974411},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-europe54678.2022.9960521","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe54678.2022.9960521","pdf_url":null,"source":{"id":"https://openalex.org/S4363608096","display_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.550000011920929,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1537901838","https://openalex.org/W1981762963","https://openalex.org/W1999795277","https://openalex.org/W2065308418","https://openalex.org/W2308257438","https://openalex.org/W2522276756","https://openalex.org/W2772167702","https://openalex.org/W2899989151","https://openalex.org/W2901273992","https://openalex.org/W2911690284","https://openalex.org/W2944175535","https://openalex.org/W2944322766","https://openalex.org/W3021181683","https://openalex.org/W4213383789","https://openalex.org/W4254745000","https://openalex.org/W6632408371"],"related_works":["https://openalex.org/W2527510741","https://openalex.org/W2538175343","https://openalex.org/W2026394348","https://openalex.org/W2495537019","https://openalex.org/W3195564279","https://openalex.org/W57526933","https://openalex.org/W2475714669","https://openalex.org/W2097324718","https://openalex.org/W1660921355","https://openalex.org/W2570926386"],"abstract_inverted_index":{"High":[0],"voltage":[1],"circuit":[2],"breakers":[3],"(HVCBs)":[4],"are":[5,88],"essential":[6],"components":[7],"for":[8,26],"reliability":[9],"and":[10,16,45,126],"resiliency":[11],"of":[12,23,28,40,56,63,107],"the":[13,97,100,105,122,128],"power":[14],"system,":[15],"it":[17],"is":[18,49,65],"crucial":[19],"to":[20,51],"optimize":[21],"principles":[22],"condition":[24,109],"monitoring":[25],"maintenance":[27,111,130],"this":[29,32],"equipment.":[30],"In":[31],"paper":[33],"a":[34,91],"novel":[35],"methodology":[36,79],"based":[37,83,110],"on":[38,84,90,96],"combination":[39],"HVCB\u2019s":[41,57,108],"overall":[42,60,129],"health":[43,61],"index":[44,62],"expected":[46],"aging":[47],"curve":[48],"presented":[50],"provide":[52],"an":[53],"optimal":[54],"scheduling":[55],"maintenance.":[58],"The":[59,78],"HVCB":[64],"acquired":[66],"by":[67],"conventional":[68],"measurements,":[69],"e.g.":[70],"contacts":[71],"dynamic":[72],"resistance,":[73],"drive":[74],"motor":[75],"current,":[76],"etc.":[77],"has":[80],"been":[81],"verified":[82],"experimental":[85],"tests":[86],"that":[87],"implemented":[89],"110":[92],"kV":[93],"HVCB.":[94],"Based":[95],"obtained":[98],"results,":[99],"proposed":[101],"method":[102],"would":[103],"increase":[104],"accuracy":[106],"scheduling,":[112],"which":[113],"will":[114],"improve":[115],"system":[116],"reliability,":[117],"ensure":[118],"personnel":[119],"safety,":[120],"reduce":[121],"unplanned":[123],"down":[124],"time,":[125],"decrease":[127],"cost.":[131]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":5}],"updated_date":"2026-02-28T09:26:25.869077","created_date":"2025-10-10T00:00:00"}
