{"id":"https://openalex.org/W4310174496","doi":"https://doi.org/10.1109/isgt-europe54678.2022.9960483","title":"An Optimization-based Approach for Automated Generation of Residential Low-Voltage Grid Models Using Open Data and Open Source Software","display_name":"An Optimization-based Approach for Automated Generation of Residential Low-Voltage Grid Models Using Open Data and Open Source Software","publication_year":2022,"publication_date":"2022-10-10","ids":{"openalex":"https://openalex.org/W4310174496","doi":"https://doi.org/10.1109/isgt-europe54678.2022.9960483"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-europe54678.2022.9960483","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe54678.2022.9960483","pdf_url":null,"source":{"id":"https://openalex.org/S4363608096","display_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5072839884","display_name":"H\u00fcseyin \u00c7akmak","orcid":"https://orcid.org/0000-0002-1463-7606"},"institutions":[{"id":"https://openalex.org/I102335020","display_name":"Karlsruhe Institute of Technology","ror":"https://ror.org/04t3en479","country_code":"DE","type":"education","lineage":["https://openalex.org/I102335020","https://openalex.org/I1305996414"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Huseyin K. Cakmak","raw_affiliation_strings":["Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","institution_ids":["https://openalex.org/I102335020"]},{"raw_affiliation_string":"Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany","institution_ids":["https://openalex.org/I102335020"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011627966","display_name":"Luc Janecke","orcid":null},"institutions":[{"id":"https://openalex.org/I102335020","display_name":"Karlsruhe Institute of Technology","ror":"https://ror.org/04t3en479","country_code":"DE","type":"education","lineage":["https://openalex.org/I102335020","https://openalex.org/I1305996414"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Luc Janecke","raw_affiliation_strings":["Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","institution_ids":["https://openalex.org/I102335020"]},{"raw_affiliation_string":"Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany","institution_ids":["https://openalex.org/I102335020"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004036457","display_name":"Moritz Weber","orcid":"https://orcid.org/0000-0002-7206-1879"},"institutions":[{"id":"https://openalex.org/I102335020","display_name":"Karlsruhe Institute of Technology","ror":"https://ror.org/04t3en479","country_code":"DE","type":"education","lineage":["https://openalex.org/I102335020","https://openalex.org/I1305996414"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Moritz Weber","raw_affiliation_strings":["Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","institution_ids":["https://openalex.org/I102335020"]},{"raw_affiliation_string":"Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany","institution_ids":["https://openalex.org/I102335020"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014228448","display_name":"Veit Hagenmeyer","orcid":"https://orcid.org/0000-0002-3572-9083"},"institutions":[{"id":"https://openalex.org/I102335020","display_name":"Karlsruhe Institute of Technology","ror":"https://ror.org/04t3en479","country_code":"DE","type":"education","lineage":["https://openalex.org/I102335020","https://openalex.org/I1305996414"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Veit Hagenmeyer","raw_affiliation_strings":["Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Automation and Applied Informatics,Karlsruhe Institute of Technology,Eggenstein-Leopoldshafen,Germany","institution_ids":["https://openalex.org/I102335020"]},{"raw_affiliation_string":"Karlsruhe Institute of Technology, Institute for Automation and Applied Informatics, Eggenstein-Leopoldshafen, Germany","institution_ids":["https://openalex.org/I102335020"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I102335020"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9873999953269958,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.7225654125213623},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.7015599608421326},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6410715579986572},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.5761046409606934},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.5252913236618042},{"id":"https://openalex.org/keywords/workflow","display_name":"Workflow","score":0.4296759068965912},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4210154414176941},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4149479269981384},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.4109748899936676},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.41050493717193604},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3728412091732025},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3463551700115204},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2252526581287384},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.21369671821594238},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.16435858607292175}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7225654125213623},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.7015599608421326},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6410715579986572},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.5761046409606934},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.5252913236618042},{"id":"https://openalex.org/C177212765","wikidata":"https://www.wikidata.org/wiki/Q627335","display_name":"Workflow","level":2,"score":0.4296759068965912},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4210154414176941},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4149479269981384},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.4109748899936676},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.41050493717193604},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3728412091732025},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3463551700115204},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2252526581287384},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21369671821594238},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.16435858607292175},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-europe54678.2022.9960483","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe54678.2022.9960483","pdf_url":null,"source":{"id":"https://openalex.org/S4363608096","display_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1971937094","https://openalex.org/W2100079043","https://openalex.org/W2108078608","https://openalex.org/W2132022337","https://openalex.org/W2315555576","https://openalex.org/W2402524951","https://openalex.org/W2521783028","https://openalex.org/W2559676662","https://openalex.org/W2804137108","https://openalex.org/W2953369294","https://openalex.org/W2990665702","https://openalex.org/W2995930209","https://openalex.org/W3096030582","https://openalex.org/W4229448232","https://openalex.org/W6679191575","https://openalex.org/W6764895796"],"related_works":["https://openalex.org/W2770234245","https://openalex.org/W96612179","https://openalex.org/W4229499248","https://openalex.org/W2566006169","https://openalex.org/W1567818861","https://openalex.org/W2987774938","https://openalex.org/W4256492088","https://openalex.org/W632915154","https://openalex.org/W2055733372","https://openalex.org/W2768554084"],"abstract_inverted_index":{"The":[0,109,147],"contribution":[1],"of":[2,16,77,126,149,209],"the":[3,13,32,57,68,78,95,124,150,187,189,196,207,210],"present":[4],"paper":[5],"is":[6,46,64,99,117,158,216],"a":[7,43,75,92,102,161,179],"new,":[8],"more":[9],"refined":[10],"method":[11,152],"for":[12,132,144,160,170,199,213],"automated":[14,119],"creation":[15],"large-scale":[17],"detailed":[18],"distribution":[19,128],"grid":[20,71,97,129,156,198],"models":[21,131,212],"based":[22],"solely":[23],"on":[24,88,140],"publicly":[25],"available":[26],"GIS":[27],"and":[28,48,116,120,137,178],"statistical":[29],"data.":[30],"Utilizing":[31],"street":[33],"layouts":[34],"in":[35,195],"Open":[36],"Street":[37],"Maps":[38],"as":[39],"potential":[40],"cable":[41],"routes,":[42],"graph":[44,62],"representation":[45,98],"created":[47],"complemented":[49],"by":[50,73],"residential":[51,141,164,175],"units":[52],"that":[53],"are":[54],"extracted":[55],"from":[56],"same":[58],"data":[59,87,139],"source.":[60],"This":[61],"structure":[63],"adjusted":[65],"to":[66,101,155],"match":[67],"electrical":[69],"low-voltage":[70,197],"topology":[72],"solving":[74],"variation":[76],"minimum":[79],"cost":[80],"flow":[81,168],"linear":[82],"optimization":[83],"problem":[84],"with":[85,153,166,182],"provided":[86],"secondary":[89],"substations.":[90],"In":[91],"final":[93],"step,":[94],"generated":[96,211],"transferred":[100],"DIgSILENT":[103],"PowerFactory":[104],"model":[105],"including":[106,173],"photovoltaic":[107,176,184,201],"systems.":[108],"presented":[110,159],"workflow":[111],"uses":[112],"open":[113],"source":[114],"software":[115],"fully":[118],"scalable.":[121],"It":[122],"allows":[123],"generation":[125],"ready-to-use":[127],"simulation":[130,190],"given":[133],"20kV":[134],"substation":[135],"locations":[136],"additional":[138],"unit":[142],"properties":[143],"improved":[145],"results.":[146],"performance":[148],"developed":[151],"respect":[154],"utilization":[157],"selected":[162],"suburban":[163],"area":[165],"power":[167],"simulations":[169,215],"eight":[171],"scenarios":[172],"current":[174],"installation":[177],"future":[180],"scenario":[181],"full":[183,200],"expansion.":[185],"For":[186],"latter,":[188],"results":[191],"indicate":[192],"heavy":[193],"congestion":[194],"capacity":[202],"deployment":[203],"without":[204],"batteries.":[205],"Furthermore,":[206],"suitability":[208],"quasi-dynamic":[214],"shown.":[217]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":5}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2022-11-30T00:00:00"}
