{"id":"https://openalex.org/W3104103561","doi":"https://doi.org/10.1109/isgt-europe47291.2020.9248932","title":"Bandwidth and Security Requirements for Smart Grid","display_name":"Bandwidth and Security Requirements for Smart Grid","publication_year":2020,"publication_date":"2020-10-26","ids":{"openalex":"https://openalex.org/W3104103561","doi":"https://doi.org/10.1109/isgt-europe47291.2020.9248932","mag":"3104103561"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-europe47291.2020.9248932","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe47291.2020.9248932","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000095337","display_name":"Kinan Ghanem","orcid":null},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"Kinan Ghanem","raw_affiliation_strings":["Power Networks Demonstration Centre, University of Strathclyde, Glasgow, UK"],"affiliations":[{"raw_affiliation_string":"Power Networks Demonstration Centre, University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091176805","display_name":"Rameez Asif","orcid":"https://orcid.org/0000-0001-5777-4670"},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Rameez Asif","raw_affiliation_strings":["Power Networks Demonstration Centre, University of Strathclyde, Glasgow, UK"],"affiliations":[{"raw_affiliation_string":"Power Networks Demonstration Centre, University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027917093","display_name":"Stephen Ugwuanyi","orcid":"https://orcid.org/0000-0001-7683-5213"},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Stephen Ugwuanyi","raw_affiliation_strings":["University of Strathclyde, Glasgow, UK"],"affiliations":[{"raw_affiliation_string":"University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5086712853","display_name":"James Irvine","orcid":"https://orcid.org/0000-0003-2078-6517"},"institutions":[{"id":"https://openalex.org/I181647926","display_name":"University of Strathclyde","ror":"https://ror.org/00n3w3b69","country_code":"GB","type":"education","lineage":["https://openalex.org/I181647926"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"James Irvine","raw_affiliation_strings":["Power Networks Demonstration Centre, University of Strathclyde, Glasgow, UK"],"affiliations":[{"raw_affiliation_string":"Power Networks Demonstration Centre, University of Strathclyde, Glasgow, UK","institution_ids":["https://openalex.org/I181647926"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5000095337"],"corresponding_institution_ids":["https://openalex.org/I181647926"],"apc_list":null,"apc_paid":null,"fwci":1.0298,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.76907307,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"36","last_page":"40"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ipsec","display_name":"IPsec","score":0.8374263644218445},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.7058452367782593},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7016010284423828},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.63764488697052},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.564010500907898},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.5420331954956055},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.500845193862915},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.3710881173610687},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17501157522201538},{"id":"https://openalex.org/keywords/the-internet","display_name":"The Internet","score":0.12322765588760376},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11695751547813416},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.11589208245277405}],"concepts":[{"id":"https://openalex.org/C67396069","wikidata":"https://www.wikidata.org/wiki/Q210214","display_name":"IPsec","level":3,"score":0.8374263644218445},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.7058452367782593},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7016010284423828},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.63764488697052},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.564010500907898},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.5420331954956055},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.500845193862915},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3710881173610687},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17501157522201538},{"id":"https://openalex.org/C110875604","wikidata":"https://www.wikidata.org/wiki/Q75","display_name":"The Internet","level":2,"score":0.12322765588760376},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11695751547813416},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.11589208245277405},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgt-europe47291.2020.9248932","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe47291.2020.9248932","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:ueaeprints.uea.ac.uk:83155","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4306400384","display_name":"UEA Digital Repository (University of East Anglia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1118541","host_organization_name":"University of East Anglia","host_organization_lineage":["https://openalex.org/I1118541"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":null,"raw_type":"NonPeerReviewed"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4300000071525574,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1969187712","https://openalex.org/W2116065935","https://openalex.org/W2193256660","https://openalex.org/W2944546806","https://openalex.org/W2955423176"],"related_works":["https://openalex.org/W2363179452","https://openalex.org/W2353156531","https://openalex.org/W2372806021","https://openalex.org/W2364007254","https://openalex.org/W2119614634","https://openalex.org/W2350524627","https://openalex.org/W2351593660","https://openalex.org/W2359714759","https://openalex.org/W2350433134","https://openalex.org/W2768554084"],"abstract_inverted_index":{"With":[0],"the":[1,24,37,49,52,106,134],"evolution":[2],"of":[3,40,66,109,118],"smart":[4],"grid":[5],"and":[6,15,33,54,72,78,83,127],"applications,":[7],"power":[8],"distribution":[9],"networks":[10],"need":[11],"scalable,":[12],"flexible,":[13],"distributed":[14],"secure":[16,133],"end-to-end":[17],"communication.":[18],"This":[19],"work":[20],"aims":[21],"to":[22,30,47,75,104,132],"highlight":[23],"necessary":[25],"bandwidth":[26,50,107,123],"that":[27],"is":[28],"needed":[29],"effectively":[31],"monitor":[32],"communicate":[34],"with":[35],"all":[36],"secondary":[38,59],"substations":[39],"Distribution":[41],"Network":[42],"Operators":[43],"(DNOs).":[44],"In":[45],"order":[46],"determine":[48],"requirements,":[51],"current":[53],"future":[55],"applications":[56],"in":[57,122],"each":[58],"substation":[60],"should":[61],"be":[62,131],"known.":[63],"Two":[64],"levels":[65],"security":[67,111],"are":[68,129],"employed":[69,87],"-":[70,74],"IPsec":[71,126],"TLS":[73,128],"give":[76],"flexibility":[77],"resilience.":[79],"Different":[80],"test":[81],"scenarios":[82],"several":[84],"setups":[85],"were":[86],"on":[88],"a":[89],"fully":[90],"secured":[91],"IP":[92],"based":[93],"Remote":[94],"Terminal":[95],"Unit":[96],"(RTU)":[97],"through":[98],"an":[99,116],"IEC":[100],"62870-05-104":[101],"protocol,":[102],"aiming":[103],"understand":[105],"cost":[108],"different":[110],"techniques.":[112],"The":[113],"analysis":[114],"depicts":[115],"average":[117],"2-3":[119],"fold":[120],"increase":[121],"if":[124],"both":[125],"used":[130],"connected":[135],"asset.":[136]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
