{"id":"https://openalex.org/W3103128186","doi":"https://doi.org/10.1109/isgt-europe47291.2020.9248862","title":"An Intelligent Measurement and Control Device for Active Distribution Grids","display_name":"An Intelligent Measurement and Control Device for Active Distribution Grids","publication_year":2020,"publication_date":"2020-10-26","ids":{"openalex":"https://openalex.org/W3103128186","doi":"https://doi.org/10.1109/isgt-europe47291.2020.9248862","mag":"3103128186"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-europe47291.2020.9248862","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe47291.2020.9248862","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041207955","display_name":"Rajkumar Palaniappan","orcid":"https://orcid.org/0000-0002-0994-0774"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Rajkumar Palaniappan","raw_affiliation_strings":["Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003842989","display_name":"Bj\u00f6rn Bauernschmitt","orcid":null},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Bjorn Bauernschmitt","raw_affiliation_strings":["Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020880868","display_name":"Dominik Hilbrich","orcid":null},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Dominik Hilbrich","raw_affiliation_strings":["Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028841407","display_name":"Christian Rehtanz","orcid":"https://orcid.org/0000-0002-8134-6841"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Christian Rehtanz","raw_affiliation_strings":["Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5041207955"],"corresponding_institution_ids":["https://openalex.org/I200332995"],"apc_list":null,"apc_paid":null,"fwci":0.2942,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.56936882,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"975","last_page":"979"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.7421059012413025},{"id":"https://openalex.org/keywords/benchmark","display_name":"Benchmark (surveying)","score":0.699710488319397},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6173110008239746},{"id":"https://openalex.org/keywords/master-station","display_name":"Master station","score":0.5104033350944519},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.47446590662002563},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.47439101338386536},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4552946388721466},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4456678330898285},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.41736310720443726},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3931419849395752},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31626224517822266},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1930103898048401},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.07393410801887512}],"concepts":[{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.7421059012413025},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.699710488319397},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6173110008239746},{"id":"https://openalex.org/C2776270902","wikidata":"https://www.wikidata.org/wiki/Q6785335","display_name":"Master station","level":3,"score":0.5104033350944519},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.47446590662002563},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.47439101338386536},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4552946388721466},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4456678330898285},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.41736310720443726},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3931419849395752},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31626224517822266},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1930103898048401},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.07393410801887512},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-europe47291.2020.9248862","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe47291.2020.9248862","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W2033796394","https://openalex.org/W2149081512","https://openalex.org/W2158762984","https://openalex.org/W2167742845","https://openalex.org/W2293321630","https://openalex.org/W2316087006","https://openalex.org/W2414435302","https://openalex.org/W2540668544","https://openalex.org/W2618635432","https://openalex.org/W2898859826","https://openalex.org/W2911137887","https://openalex.org/W2979511714","https://openalex.org/W2981757435","https://openalex.org/W2982370310","https://openalex.org/W6729445896"],"related_works":["https://openalex.org/W2378211422","https://openalex.org/W2745001401","https://openalex.org/W4321353415","https://openalex.org/W2130974462","https://openalex.org/W972276598","https://openalex.org/W4246352526","https://openalex.org/W2028665553","https://openalex.org/W2086519370","https://openalex.org/W4312709492","https://openalex.org/W2357190460"],"abstract_inverted_index":{"This":[0,77],"paper":[1,30],"deals":[2],"with":[3],"the":[4,22,27,33,36,56,65,73,91,112,118,122,128,135,144,147],"development":[5],"of":[6,26,35,90,96,134,146],"a":[7,43,83,99,105,110,161,168,172],"unified":[8,49],"system":[9,50],"architecture":[10],"that":[11,79,143],"is":[12,70,104,115,153,158],"able":[13],"to":[14,82,109,117,141],"provide":[15],"both":[16],"protection":[17,38],"and":[18,39,94,137,152],"control":[19,40,125],"possibilities":[20],"for":[21],"active":[23],"distribution":[24,57,92],"grids":[25],"future.":[28],"The":[29,48,124,156],"focusses":[31],"on":[32,42,64,160],"co-ordination":[34],"developed":[37],"algorithms":[41],"power":[44],"quality":[45],"measurement":[46],"device.":[47,66],"utilizes":[51],"decentralized":[52],"measurements":[53],"distributed":[54],"across":[55],"grid.":[58],"Several":[59],"functions":[60],"are":[61,87],"already":[62],"implemented":[63],"A":[67],"hierarchical":[68],"approach":[69],"followed":[71],"by":[72],"voltage":[74,165],"regulation":[75],"algorithm.":[76],"means":[78],"in":[80,171],"addition":[81],"global":[84],"master,":[85],"there":[86,103],"several":[88],"branches":[89],"grid":[93,136,148,166],"each":[95],"them":[97],"has":[98],"sub-master":[100],"system.":[101],"When":[102],"trip":[106,113],"activatied":[107],"due":[108],"fault,":[111],"information":[114],"communicated":[116],"central":[119],"master":[120,129],"or":[121],"sub-master.":[123],"algorithm":[126,157],"at":[127],"device":[130],"neglects":[131],"this":[132],"part":[133],"takes":[138],"necessary":[139],"steps":[140],"ensure":[142],"rest":[145],"still":[149],"remains":[150],"protected":[151],"under":[154],"control.":[155],"validated":[159],"Cigr\u00e9":[162],"Benchmark":[163],"medium":[164],"using":[167],"real-time":[169],"simulator":[170],"hardware-in-the-loop":[173],"setup.":[174]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
