{"id":"https://openalex.org/W3103189078","doi":"https://doi.org/10.1109/isgt-europe47291.2020.9248841","title":"Aggregated Power Quality Indicator for Controlling a Hybrid Compensation System Providing System Services","display_name":"Aggregated Power Quality Indicator for Controlling a Hybrid Compensation System Providing System Services","publication_year":2020,"publication_date":"2020-10-26","ids":{"openalex":"https://openalex.org/W3103189078","doi":"https://doi.org/10.1109/isgt-europe47291.2020.9248841","mag":"3103189078"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-europe47291.2020.9248841","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe47291.2020.9248841","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022670700","display_name":"Ralf Merkl","orcid":null},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]},{"id":"https://openalex.org/I4210157642","display_name":"Institute of Automation","ror":"https://ror.org/056qj1t15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210157642","https://openalex.org/I78650965"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Ralf Merkl","raw_affiliation_strings":["Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universit\u00e4t, Erlangen-N\u00fcrnberg, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universit\u00e4t, Erlangen-N\u00fcrnberg, Germany","institution_ids":["https://openalex.org/I4210157642","https://openalex.org/I181369854"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027496810","display_name":"Michael Steglich","orcid":null},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Michael Steglich","raw_affiliation_strings":["Institute of Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Germany"],"affiliations":[{"raw_affiliation_string":"Institute of Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022676842","display_name":"Martin Paulsburg","orcid":null},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]},{"id":"https://openalex.org/I4210157642","display_name":"Institute of Automation","ror":"https://ror.org/056qj1t15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210157642","https://openalex.org/I78650965"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Paulsburg","raw_affiliation_strings":["Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universit\u00e4t, Erlangen-N\u00fcrnberg, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universit\u00e4t, Erlangen-N\u00fcrnberg, Germany","institution_ids":["https://openalex.org/I4210157642","https://openalex.org/I181369854"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028841407","display_name":"Christian Rehtanz","orcid":"https://orcid.org/0000-0002-8134-6841"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Christian Rehtanz","raw_affiliation_strings":["Institute of Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Germany"],"affiliations":[{"raw_affiliation_string":"Institute of Energy Systems, Energy Efficiency and Energy Economics (ie3), TU Dortmund University, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5059197069","display_name":"J\u00f6rg Franke","orcid":"https://orcid.org/0000-0003-0700-2028"},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]},{"id":"https://openalex.org/I4210157642","display_name":"Institute of Automation","ror":"https://ror.org/056qj1t15","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210157642","https://openalex.org/I78650965"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jorg Franke","raw_affiliation_strings":["Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universit\u00e4t, Erlangen-N\u00fcrnberg, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Factory Automation and Production Systems (FAPS), Friedrich-Alexander-Universit\u00e4t, Erlangen-N\u00fcrnberg, Germany","institution_ids":["https://openalex.org/I4210157642","https://openalex.org/I181369854"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5022670700"],"corresponding_institution_ids":["https://openalex.org/I181369854","https://openalex.org/I4210157642"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.11337868,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"12","issue":null,"first_page":"700","last_page":"704"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.8223189115524292},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.6438586711883545},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.6419687867164612},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5831335783004761},{"id":"https://openalex.org/keywords/quality","display_name":"Quality (philosophy)","score":0.5589303374290466},{"id":"https://openalex.org/keywords/power-quality","display_name":"Power quality","score":0.5313501954078674},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5223979949951172},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4939461350440979},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4876745939254761},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.4569372236728668},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4533277750015259},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4462757706642151},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.43674778938293457},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.41333261132240295},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.35962414741516113},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.31878435611724854},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29678916931152344},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1243169903755188}],"concepts":[{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.8223189115524292},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.6438586711883545},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.6419687867164612},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5831335783004761},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.5589303374290466},{"id":"https://openalex.org/C2779665505","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Power quality","level":3,"score":0.5313501954078674},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5223979949951172},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4939461350440979},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4876745939254761},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.4569372236728668},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4533277750015259},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4462757706642151},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.43674778938293457},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41333261132240295},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.35962414741516113},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.31878435611724854},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29678916931152344},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1243169903755188},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C111472728","wikidata":"https://www.wikidata.org/wiki/Q9471","display_name":"Epistemology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-europe47291.2020.9248841","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-europe47291.2020.9248841","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1265484983","https://openalex.org/W1509703948","https://openalex.org/W1660883632","https://openalex.org/W1966862616","https://openalex.org/W2136886571","https://openalex.org/W2140721288","https://openalex.org/W2151989212","https://openalex.org/W2295190654","https://openalex.org/W2541478771","https://openalex.org/W2765463085","https://openalex.org/W2775652363","https://openalex.org/W2901893963","https://openalex.org/W2975483739","https://openalex.org/W3103960010","https://openalex.org/W4236532651","https://openalex.org/W4252304724","https://openalex.org/W6627996417","https://openalex.org/W7000076572"],"related_works":["https://openalex.org/W2810491476","https://openalex.org/W4382929618","https://openalex.org/W4224929845","https://openalex.org/W4289363416","https://openalex.org/W2911298097","https://openalex.org/W2376772961","https://openalex.org/W2376722172","https://openalex.org/W2185400004","https://openalex.org/W2369535890","https://openalex.org/W2360369074"],"abstract_inverted_index":{"In":[0],"electric":[1],"energy":[2],"distribution,":[3],"a":[4,46,62],"defined":[5],"level":[6,52,80],"of":[7,24,53,61,72,89,102,123],"power":[8,25,34,38,54,60,73,92,104,115,130],"quality":[9,39,55,74,93,105,116,131],"is":[10],"to":[11,17,65],"be":[12],"maintained":[13],"at":[14],"all":[15],"times":[16],"ensure":[18],"reliable":[19],"grid":[20],"operation.":[21],"Increased":[22],"connection":[23],"electronic":[26],"feeders":[27],"and":[28,56,81,126],"loads":[29],"as":[30,32,75],"well":[31,97],"fluctuating":[33],"plants":[35],"introduces":[36],"time-varying":[37],"deviations.":[40],"Within":[41],"this":[42],"article,":[43],"we":[44,84,107],"propose":[45],"concept":[47],"for":[48,100,111],"determining":[49,112],"the":[50,58,90,113],"present":[51,91],"distributing":[57],"available":[59],"compensation":[63],"system":[64],"individual":[66,103],"services.":[67],"Focusing":[68],"on":[69],"steady-state":[70],"phenomena":[71],"harmonics,":[76],"unbalance,":[77],"frequency,":[78],"voltage":[79],"phase":[82],"angle":[83],"calculate":[85],"an":[86],"aggregated":[87,114],"indicator":[88],"level.":[94],"By":[95],"applying":[96],"known":[98],"procedures":[99],"calculation":[101],"parameters":[106],"obtain":[108],"required":[109],"data":[110],"index.":[117],"Restrictions":[118],"are":[119],"imposed":[120],"by":[121,129],"means":[122],"dead":[124],"bands":[125],"limits":[127],"specified":[128],"standards.":[132]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
