{"id":"https://openalex.org/W2808475062","doi":"https://doi.org/10.1109/isgt-asia.2017.8378333","title":"Coordinated operation scheduling method for BESS and thermal generators based on photovoltaic generation forecasts released every several hours","display_name":"Coordinated operation scheduling method for BESS and thermal generators based on photovoltaic generation forecasts released every several hours","publication_year":2017,"publication_date":"2017-12-01","ids":{"openalex":"https://openalex.org/W2808475062","doi":"https://doi.org/10.1109/isgt-asia.2017.8378333","mag":"2808475062"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-asia.2017.8378333","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-asia.2017.8378333","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Innovative Smart Grid Technologies - Asia (ISGT-Asia)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064735568","display_name":"Daiki Kobauashi","orcid":null},"institutions":[{"id":"https://openalex.org/I96636082","display_name":"Meijo University","ror":"https://ror.org/04h42fc75","country_code":"JP","type":"education","lineage":["https://openalex.org/I96636082"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Daiki Kobauashi","raw_affiliation_strings":["Dept. of Electrical and Electronic Engineering, Meijo University, Nagoya, Japan"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical and Electronic Engineering, Meijo University, Nagoya, Japan","institution_ids":["https://openalex.org/I96636082"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004160899","display_name":"Taisuke Masuta","orcid":"https://orcid.org/0000-0002-7647-8102"},"institutions":[{"id":"https://openalex.org/I96636082","display_name":"Meijo University","ror":"https://ror.org/04h42fc75","country_code":"JP","type":"education","lineage":["https://openalex.org/I96636082"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Taisuke Masuta","raw_affiliation_strings":["Dept. of Electrical and Electronic Engineering, Meijo University, Nagoya, Japan"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical and Electronic Engineering, Meijo University, Nagoya, Japan","institution_ids":["https://openalex.org/I96636082"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035700483","display_name":"Hideaki Ohtake","orcid":"https://orcid.org/0000-0002-3061-0382"},"institutions":[{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Hideaki Ohtake","raw_affiliation_strings":["National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan"],"affiliations":[{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan","institution_ids":["https://openalex.org/I73613424"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5064735568"],"corresponding_institution_ids":["https://openalex.org/I96636082"],"apc_list":null,"apc_paid":null,"fwci":0.9751,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.83082538,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11276","display_name":"Solar Radiation and Photovoltaics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11276","display_name":"Solar Radiation and Photovoltaics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.8114333152770996},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6491797566413879},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5192875266075134},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.5170522332191467},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5053853988647461},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.4191294312477112},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3919101357460022},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2831628918647766},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.24260932207107544},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.1355806291103363}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.8114333152770996},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6491797566413879},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5192875266075134},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.5170522332191467},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5053853988647461},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.4191294312477112},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3919101357460022},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2831628918647766},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.24260932207107544},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.1355806291103363},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-asia.2017.8378333","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-asia.2017.8378333","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Innovative Smart Grid Technologies - Asia (ISGT-Asia)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8700000047683716,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2043057228","https://openalex.org/W2054770122","https://openalex.org/W2612494406","https://openalex.org/W6664093712"],"related_works":["https://openalex.org/W2386968573","https://openalex.org/W2395064349","https://openalex.org/W2034374297","https://openalex.org/W2382628689","https://openalex.org/W2766130412","https://openalex.org/W2526730640","https://openalex.org/W2351171996","https://openalex.org/W2983370139","https://openalex.org/W2057543190","https://openalex.org/W2612874294"],"abstract_inverted_index":{"The":[0,112],"application":[1],"of":[2,18,90,137],"photovoltaic":[3],"(PV)":[4],"generation":[5],"forecasting":[6,47,52],"to":[7,35,45,133],"supply-demand":[8,25,143],"operation":[9],"is":[10,43,53,58,114],"essential":[11],"for":[12,86,102,141],"power":[13,29,62,119],"systems":[14,63],"with":[15,64],"large":[16,66],"integrations":[17],"PV":[19,38,56,68,91,118],"generation.":[20],"Forecasting":[21],"errors":[22],"may":[23],"cause":[24],"imbalances":[26],"such":[27,76],"as":[28,77],"shortfall":[30],"and":[31,37,105,124],"surplus,":[32],"which":[33],"lead":[34],"outage":[36],"curtailment,":[39],"respectively.":[40],"Thus,":[41],"it":[42],"important":[44],"improve":[46],"accuracy.":[48],"However,":[49],"even":[50],"if":[51],"completely":[54],"accurate,":[55],"curtailment":[57],"occasionally":[59],"necessary":[60,85],"in":[61],"extremely":[65],"installed":[67],"capacity.":[69],"In":[70,93],"this":[71,94],"case,":[72],"energy":[73,80],"storage":[74,81],"devices,":[75],"a":[78,98,103],"battery":[79],"system":[82],"(BESS),":[83],"are":[84,122,131],"more":[87],"efficient":[88],"use":[89],"energy.":[92],"study,":[95],"we":[96],"propose":[97],"coordinated":[99],"control":[100],"method":[101,113,140],"BESS":[104],"thermal":[106],"generators":[107],"considering":[108],"their":[109],"unit":[110],"commitment.":[111],"based":[115],"on":[116],"forecasted":[117],"outputs":[120],"that":[121],"released":[123],"updated":[125],"every":[126],"several":[127],"hours.":[128],"Numerical":[129],"simulations":[130],"conducted":[132],"evaluate":[134],"the":[135,138],"effectiveness":[136],"proposed":[139],"decreasing":[142],"imbalances.":[144]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
