{"id":"https://openalex.org/W2247295680","doi":"https://doi.org/10.1109/isgt-asia.2015.7387051","title":"Efficiency comparison of DC and AC microgrid","display_name":"Efficiency comparison of DC and AC microgrid","publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2247295680","doi":"https://doi.org/10.1109/isgt-asia.2015.7387051","mag":"2247295680"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-asia.2015.7387051","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-asia.2015.7387051","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088149412","display_name":"Ujjal Manandhar","orcid":"https://orcid.org/0000-0003-2669-2095"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":true,"raw_author_name":"Ujjal Manandhar","raw_affiliation_strings":["School of EEE, Nanyang Technological University, Singapore","School of EEE Nanyang, Technological University, , Singapore"],"affiliations":[{"raw_affiliation_string":"School of EEE, Nanyang Technological University, Singapore","institution_ids":["https://openalex.org/I172675005"]},{"raw_affiliation_string":"School of EEE Nanyang, Technological University, , Singapore","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086713046","display_name":"Abhisek Ukil","orcid":"https://orcid.org/0000-0003-3100-7865"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Abhisek Ukil","raw_affiliation_strings":["School of EEE, Nanyang Technological University, Singapore","School of EEE Nanyang, Technological University, , Singapore"],"affiliations":[{"raw_affiliation_string":"School of EEE, Nanyang Technological University, Singapore","institution_ids":["https://openalex.org/I172675005"]},{"raw_affiliation_string":"School of EEE Nanyang, Technological University, , Singapore","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079334017","display_name":"Tan Keng Kiat Jonathan","orcid":null},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Tan Keng Kiat Jonathan","raw_affiliation_strings":["School of EEE, Nanyang Technological University, Singapore, Singapore, SG","School of EEE Nanyang, Technological University, , Singapore"],"affiliations":[{"raw_affiliation_string":"School of EEE, Nanyang Technological University, Singapore, Singapore, SG","institution_ids":["https://openalex.org/I172675005"]},{"raw_affiliation_string":"School of EEE Nanyang, Technological University, , Singapore","institution_ids":["https://openalex.org/I172675005"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5088149412"],"corresponding_institution_ids":["https://openalex.org/I172675005"],"apc_list":null,"apc_paid":null,"fwci":3.0588,"has_fulltext":false,"cited_by_count":70,"citation_normalized_percentile":{"value":0.91994424,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.7232409715652466},{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.6217319965362549},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.6155837774276733},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5936971306800842},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5682159662246704},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5287860035896301},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.45488572120666504},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43937593698501587},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.4253781735897064},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.38053637742996216},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3169586658477783},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2466752827167511},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09491893649101257}],"concepts":[{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.7232409715652466},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.6217319965362549},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.6155837774276733},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5936971306800842},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5682159662246704},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5287860035896301},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45488572120666504},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43937593698501587},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.4253781735897064},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.38053637742996216},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3169586658477783},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2466752827167511},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09491893649101257},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-asia.2015.7387051","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-asia.2015.7387051","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8500000238418579,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1514840064","https://openalex.org/W1573847156","https://openalex.org/W1644949399","https://openalex.org/W1740445234","https://openalex.org/W1777802217","https://openalex.org/W1970900775","https://openalex.org/W2034362646","https://openalex.org/W2062984086","https://openalex.org/W2098711962","https://openalex.org/W2120037660","https://openalex.org/W2146930136","https://openalex.org/W2158017035","https://openalex.org/W2161058969","https://openalex.org/W2169891281","https://openalex.org/W2178386635","https://openalex.org/W2316279463","https://openalex.org/W2340095030","https://openalex.org/W2555427451","https://openalex.org/W3147537413","https://openalex.org/W6678184147","https://openalex.org/W6683809248","https://openalex.org/W6684682598","https://openalex.org/W6699439401","https://openalex.org/W6704115521","https://openalex.org/W6729734736"],"related_works":["https://openalex.org/W2283247349","https://openalex.org/W3115065686","https://openalex.org/W2808568537","https://openalex.org/W2096121481","https://openalex.org/W2212320229","https://openalex.org/W4310353322","https://openalex.org/W2534811423","https://openalex.org/W2349214957","https://openalex.org/W2380177640","https://openalex.org/W4390045340"],"abstract_inverted_index":{"As":[0],"the":[1,12,25,34,38,43,53,58,81,85,88,92,101,108,112,139,142,149],"number":[2],"of":[3,62,119,148,151],"DC":[4,15,44,59,126],"loads":[5],"are":[6,133],"growing":[7],"in":[8,100,117,130],"our":[9],"daily":[10],"uses,":[11],"low":[13,26],"voltage":[14,27],"(LVDC)":[16],"distribution":[17,30,115,144,156],"system":[18,31,49,83,116,153,157],"is":[19],"becoming":[20],"important.":[21],"Power":[22],"supplied":[23],"through":[24],"AC":[28,124],"(LVAC)":[29],"needs":[32],"both":[33,138],"AC/DC":[35],"rectifier":[36],"and":[37,125,141],"DC/DC":[39,54],"converter":[40,55,120],"to":[41,56,95],"supply":[42,57],"loads.":[45,60],"In":[46],"comparison,":[47],"LVDC":[48,82,89,114,143,152],"would":[50,76],"only":[51],"need":[52],"Integration":[61],"renewable":[63],"energy":[64],"sources":[65],"at":[66],"LV":[67],"level,":[68],"like":[69],"rooftop":[70],"photovoltaic":[71],"(PV),":[72],"fuel":[73],"cells,":[74],"etc.":[75],"be":[77,91],"relatively":[78],"easier":[79],"with":[80,111],"than":[84],"LVAC.":[86],"So,":[87],"can":[90],"viable":[93],"solution":[94],"reduce":[96],"multiple":[97],"conversion":[98,121],"losses":[99],"system.":[102,145],"This":[103],"paper":[104],"presents":[105],"comparison":[106],"between":[107],"existing":[109],"LVAC":[110,140,155],"prospective":[113],"terms":[118],"efficiency.":[122],"Constant":[123],"loads,":[127],"generally":[128],"used":[129],"household":[131],"applications,":[132],"simulated":[134],"using":[135],"PSCAD/EMTDC":[136],"for":[137],"The":[146],"analysis":[147],"effectiveness":[150],"over":[154],"has":[158],"been":[159],"presented.":[160]},"counts_by_year":[{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":9},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":10},{"year":2021,"cited_by_count":11},{"year":2020,"cited_by_count":11},{"year":2019,"cited_by_count":8},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":4}],"updated_date":"2026-03-06T13:50:29.536080","created_date":"2025-10-10T00:00:00"}
