{"id":"https://openalex.org/W2249204633","doi":"https://doi.org/10.1109/isgt-asia.2015.7386983","title":"Building HVAC load profiling using EnergyPlus","display_name":"Building HVAC load profiling using EnergyPlus","publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2249204633","doi":"https://doi.org/10.1109/isgt-asia.2015.7386983","mag":"2249204633"},"language":"en","primary_location":{"id":"doi:10.1109/isgt-asia.2015.7386983","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-asia.2015.7386983","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088149412","display_name":"Ujjal Manandhar","orcid":"https://orcid.org/0000-0003-2669-2095"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":true,"raw_author_name":"Ujjal Manandhar","raw_affiliation_strings":["School of EEE, Nanyang Technological University, Singapore"],"affiliations":[{"raw_affiliation_string":"School of EEE, Nanyang Technological University, Singapore","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086713046","display_name":"Abhisek Ukil","orcid":"https://orcid.org/0000-0003-3100-7865"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Abhisek Ukil","raw_affiliation_strings":["School of EEE, Nanyang Technological University, Singapore"],"affiliations":[{"raw_affiliation_string":"School of EEE, Nanyang Technological University, Singapore","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100391512","display_name":"Dong Wang","orcid":"https://orcid.org/0000-0002-8569-8713"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Dong Wang","raw_affiliation_strings":["School of EEE, Nanyang Technological University, Singapore"],"affiliations":[{"raw_affiliation_string":"School of EEE, Nanyang Technological University, Singapore","institution_ids":["https://openalex.org/I172675005"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5088149412"],"corresponding_institution_ids":["https://openalex.org/I172675005"],"apc_list":null,"apc_paid":null,"fwci":1.8906,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.86733015,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9840999841690063,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9559598565101624},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6764107942581177},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.5931610465049744},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.583373486995697},{"id":"https://openalex.org/keywords/profiling","display_name":"Profiling (computer programming)","score":0.5808733701705933},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5542141199111938},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5033900141716003},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4492926001548767},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.4352220892906189},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.4312770366668701},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3952053189277649},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.36570507287979126},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.36475324630737305},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.33552730083465576},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.3307580351829529},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.25955796241760254},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12895867228507996},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.12076053023338318},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.10347312688827515}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9559598565101624},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6764107942581177},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5931610465049744},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.583373486995697},{"id":"https://openalex.org/C187191949","wikidata":"https://www.wikidata.org/wiki/Q1138496","display_name":"Profiling (computer programming)","level":2,"score":0.5808733701705933},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5542141199111938},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5033900141716003},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4492926001548767},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.4352220892906189},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.4312770366668701},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3952053189277649},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.36570507287979126},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.36475324630737305},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.33552730083465576},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3307580351829529},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25955796241760254},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12895867228507996},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.12076053023338318},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.10347312688827515},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgt-asia.2015.7386983","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgt-asia.2015.7386983","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1644949399","https://openalex.org/W1981967873","https://openalex.org/W2012072009","https://openalex.org/W2032717142","https://openalex.org/W2161058969","https://openalex.org/W2163121678","https://openalex.org/W2276291879","https://openalex.org/W2277709061","https://openalex.org/W6683809248"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W4205684936","https://openalex.org/W3194241082","https://openalex.org/W3174885725","https://openalex.org/W3207683219","https://openalex.org/W2606841152"],"abstract_inverted_index":{"Building":[0],"load":[1,35,65],"profiling":[2],"plays":[3],"an":[4],"important":[5],"part":[6],"in":[7,95,120],"the":[8,27,45,51,64,89,96,124],"development":[9],"of":[10,26,77,92],"optimal":[11,37],"energy":[12,29,47,53,110,113,121,126],"management":[13],"systems.":[14],"Heating,":[15],"Ventilation,":[16],"Air":[17],"Conditioning":[18],"(HVAC)":[19],"systems":[20],"consume":[21],"around":[22],"40%":[23],"to":[24,43,62,108,118],"50%":[25],"total":[28],"consumed":[30],"by":[31],"buildings.":[32],"Using":[33],"this":[34,56],"data,":[36],"operation":[38,97],"scheduling":[39,100],"can":[40],"be":[41,106],"determined":[42],"reduce":[44],"peak":[46],"requirement":[48],"and":[49,81,101],"minimize":[50],"overall":[52,125],"consumption.":[54,127],"In":[55],"paper,":[57],"EnergyPlus":[58],"software":[59],"is":[60,94],"used":[61],"simulate":[63],"profiles":[66],"for":[67,70],"HVAC":[68],"loads,":[69],"a":[71],"given":[72],"building":[73],"design.":[74],"Different":[75],"types":[76,91],"buildings,":[78],"namely":[79],"residential":[80],"commercial":[82],"are":[83],"considered.":[84],"The":[85,99,112],"main":[86],"difference":[87],"between":[88],"different":[90],"buildings":[93],"scheduling.":[98],"parameter":[102],"like":[103],"temperature":[104],"could":[105],"altered":[107],"derive":[109],"savings.":[111],"savings":[114],"would":[115],"significantly":[116],"contribute":[117],"reduction":[119],"peak,":[122],"minimizing":[123]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
