{"id":"https://openalex.org/W4378373718","doi":"https://doi.org/10.1109/isdfs58141.2023.10131854","title":"A Deep Learning Method to Predict Loss of Coolant Accident in Nuclear Power Plants","display_name":"A Deep Learning Method to Predict Loss of Coolant Accident in Nuclear Power Plants","publication_year":2023,"publication_date":"2023-05-11","ids":{"openalex":"https://openalex.org/W4378373718","doi":"https://doi.org/10.1109/isdfs58141.2023.10131854"},"language":"en","primary_location":{"id":"doi:10.1109/isdfs58141.2023.10131854","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isdfs58141.2023.10131854","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 11th International Symposium on Digital Forensics and Security (ISDFS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056283974","display_name":"Faiyaz Fahim","orcid":"https://orcid.org/0000-0002-4659-5797"},"institutions":[{"id":"https://openalex.org/I183697816","display_name":"Bangladesh University of Engineering and Technology","ror":"https://ror.org/05a1qpv97","country_code":"BD","type":"education","lineage":["https://openalex.org/I183697816"]}],"countries":["BD"],"is_corresponding":true,"raw_author_name":"Faiyaz Fahim","raw_affiliation_strings":["Bangladesh Army University of Engineering and Technology,Department of Electrical and Electronic Engineering,Natore,Bangladesh","Department of Electrical and Electronic Engineering, Bangladesh Army University of Engineering and Technology, Natore, Bangladesh"],"affiliations":[{"raw_affiliation_string":"Bangladesh Army University of Engineering and Technology,Department of Electrical and Electronic Engineering,Natore,Bangladesh","institution_ids":["https://openalex.org/I183697816"]},{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Bangladesh Army University of Engineering and Technology, Natore, Bangladesh","institution_ids":["https://openalex.org/I183697816"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5056283974"],"corresponding_institution_ids":["https://openalex.org/I183697816"],"apc_list":null,"apc_paid":null,"fwci":1.0806,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.73320283,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11606","display_name":"Infrastructure Maintenance and Monitoring","score":0.9918000102043152,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11606","display_name":"Infrastructure Maintenance and Monitoring","score":0.9918000102043152,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9855999946594238,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T11490","display_name":"Hydrological Forecasting Using AI","score":0.942300021648407,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nonlinear-autoregressive-exogenous-model","display_name":"Nonlinear autoregressive exogenous model","score":0.7399914264678955},{"id":"https://openalex.org/keywords/loss-of-coolant-accident","display_name":"Loss-of-coolant accident","score":0.6664878726005554},{"id":"https://openalex.org/keywords/nuclear-power-plant","display_name":"Nuclear power plant","score":0.6282862424850464},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6101300120353699},{"id":"https://openalex.org/keywords/nuclear-power","display_name":"Nuclear power","score":0.5740293860435486},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.5000762939453125},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.41257408261299133},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.41066163778305054},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.36429619789123535},{"id":"https://openalex.org/keywords/coolant","display_name":"Coolant","score":0.35538724064826965},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2788246273994446},{"id":"https://openalex.org/keywords/nuclear-physics","display_name":"Nuclear physics","score":0.10938316583633423},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08175551891326904},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.073121577501297}],"concepts":[{"id":"https://openalex.org/C42536954","wikidata":"https://www.wikidata.org/wiki/Q7049462","display_name":"Nonlinear autoregressive exogenous model","level":3,"score":0.7399914264678955},{"id":"https://openalex.org/C2778917722","wikidata":"https://www.wikidata.org/wiki/Q1071740","display_name":"Loss-of-coolant accident","level":3,"score":0.6664878726005554},{"id":"https://openalex.org/C2779979336","wikidata":"https://www.wikidata.org/wiki/Q134447","display_name":"Nuclear power plant","level":2,"score":0.6282862424850464},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6101300120353699},{"id":"https://openalex.org/C513653683","wikidata":"https://www.wikidata.org/wiki/Q12739","display_name":"Nuclear power","level":2,"score":0.5740293860435486},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.5000762939453125},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.41257408261299133},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41066163778305054},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.36429619789123535},{"id":"https://openalex.org/C91914117","wikidata":"https://www.wikidata.org/wiki/Q1056832","display_name":"Coolant","level":2,"score":0.35538724064826965},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2788246273994446},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.10938316583633423},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08175551891326904},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.073121577501297},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isdfs58141.2023.10131854","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isdfs58141.2023.10131854","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 11th International Symposium on Digital Forensics and Security (ISDFS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.550000011920929,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2172017592","https://openalex.org/W2226733402","https://openalex.org/W2556046789","https://openalex.org/W2569887921","https://openalex.org/W2765854388","https://openalex.org/W2795800097","https://openalex.org/W3041022594","https://openalex.org/W3161373808","https://openalex.org/W3197391102","https://openalex.org/W4223512144","https://openalex.org/W4237403636","https://openalex.org/W6685247619"],"related_works":["https://openalex.org/W2036955414","https://openalex.org/W3035220369","https://openalex.org/W2195725131","https://openalex.org/W64152743","https://openalex.org/W4312785970","https://openalex.org/W2009405292","https://openalex.org/W2063979910","https://openalex.org/W48099765","https://openalex.org/W2355271351","https://openalex.org/W2398050733"],"abstract_inverted_index":{"Nuclear":[0],"safety":[1],"is":[2,18],"crucial":[3],"for":[4,21],"the":[5,33,49,54,77,114,143],"reliable":[6],"operation":[7],"of":[8,23,32,81,92,123,127],"nuclear":[9,24,84],"power":[10,25,85],"plants":[11,26],"in":[12,70,73,103],"order":[13,74,107],"to":[14,27,45,48,68,75,108,141],"produce":[15],"electricity.":[16],"It":[17],"very":[19],"difficult":[20],"operators":[22],"foresee":[28],"and":[29],"recognize":[30],"one":[31],"most":[34],"catastrophic":[35],"accident":[36],"scenarios,":[37],"often":[38],"known":[39,98],"as":[40,42,51,53,63,99],"LOCA,":[41],"they":[43],"have":[44],"pay":[46],"attention":[47],"non-linearity":[50],"well":[52],"complex":[55],"system":[56,124],"factors":[57],"involved.":[58],"Artificial":[59],"intelligence-based":[60],"applications,":[61],"such":[62],"deep":[64],"learning,":[65],"are":[66],"put":[67],"use":[69],"this":[71,104],"research":[72],"predict":[76],"time":[78],"series":[79],"evolution":[80],"a":[82,90,120,132],"simulation-based":[83],"plant":[86],"incident":[87],"that":[88,152],"involves":[89],"loss":[91],"coolant":[93],"accident.":[94],"A":[95],"neural":[96],"network":[97],"NARX":[100,115,153],"was":[101,117,139],"employed":[102,118],"research.":[105,160],"In":[106],"provide":[109],"an":[110],"accurate":[111],"LOCA":[112],"prediction,":[113],"model":[116,144],"with":[119],"wide":[121],"range":[122],"parameters,":[125],"all":[126],"which":[128],"were":[129],"aggregated":[130],"into":[131],"twelve-dimensional":[133],"input":[134],"vector.":[135],"Mean":[136],"Squared":[137],"Error":[138],"used":[140],"evaluate":[142],"efficacy.":[145],"Furthermore,":[146],"it":[147],"has":[148],"also":[149],"been":[150],"observed":[151],"performs":[154],"much":[155],"better":[156],"than":[157],"other":[158],"leading-edge":[159]},"counts_by_year":[{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
