{"id":"https://openalex.org/W4416222898","doi":"https://doi.org/10.1109/iscc65549.2025.11325991","title":"HyPM: Hybrid Performance Metric Transmission in Low-Power Wireless Networks","display_name":"HyPM: Hybrid Performance Metric Transmission in Low-Power Wireless Networks","publication_year":2025,"publication_date":"2025-07-02","ids":{"openalex":"https://openalex.org/W4416222898","doi":"https://doi.org/10.1109/iscc65549.2025.11325991"},"language":"en","primary_location":{"id":"doi:10.1109/iscc65549.2025.11325991","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscc65549.2025.11325991","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Symposium on Computers and Communications (ISCC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://inria.hal.science/hal-05030266/document","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113261633","display_name":"Fabian Graf","orcid":null},"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Fabian Graf","raw_affiliation_strings":["Siemens AG Siemens Technology,Erlangen,Germany","Siemens  AG [Erlangen] (Germany)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens AG Siemens Technology,Erlangen,Germany","institution_ids":["https://openalex.org/I1325886976"]},{"raw_affiliation_string":"Siemens  AG [Erlangen] (Germany)","institution_ids":["https://openalex.org/I1325886976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5120498063","display_name":"Esteban Norena Arroyave","orcid":null},"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Esteban Nore\u00f1a Arroyave","raw_affiliation_strings":["Siemens AG Siemens Technology,Erlangen,Germany","Siemens  AG [Erlangen] (Germany)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens AG Siemens Technology,Erlangen,Germany","institution_ids":["https://openalex.org/I1325886976"]},{"raw_affiliation_string":"Siemens  AG [Erlangen] (Germany)","institution_ids":["https://openalex.org/I1325886976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110360481","display_name":"Thomas Watteyne","orcid":null},"institutions":[{"id":"https://openalex.org/I1326498283","display_name":"Institut national de recherche en sciences et technologies du num\u00e9rique","ror":"https://ror.org/02kvxyf05","country_code":"FR","type":"government","lineage":["https://openalex.org/I1326498283"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Thomas Watteyne","raw_affiliation_strings":["Inria AIO Team,Paris,France","AIO - Mise en r\u00e9seau fiable, sans fil \u00e0 faible consommation et micro-robotique (48 Rue Barrault, 75013 Paris - France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Inria AIO Team,Paris,France","institution_ids":["https://openalex.org/I1326498283"]},{"raw_affiliation_string":"AIO - Mise en r\u00e9seau fiable, sans fil \u00e0 faible consommation et micro-robotique (48 Rue Barrault, 75013 Paris - France)","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5055094713","display_name":"Michael Villnow","orcid":null},"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Michael Villnow","raw_affiliation_strings":["Siemens AG Siemens Technology,Erlangen,Germany","Siemens  AG [Erlangen] (Germany)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens AG Siemens Technology,Erlangen,Germany","institution_ids":["https://openalex.org/I1325886976"]},{"raw_affiliation_string":"Siemens  AG [Erlangen] (Germany)","institution_ids":["https://openalex.org/I1325886976"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.22619999945163727,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.22619999945163727,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.21960000693798065,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12079","display_name":"IoT Networks and Protocols","score":0.14180000126361847,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.5667999982833862},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.4961000084877014},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.47510001063346863},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.47450000047683716},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.43950000405311584},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.42829999327659607},{"id":"https://openalex.org/keywords/telemetry","display_name":"Telemetry","score":0.42320001125335693},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.4124999940395355},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.40529999136924744}],"concepts":[{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6851000189781189},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6144999861717224},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.5667999982833862},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.4961000084877014},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.47510001063346863},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.47450000047683716},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.43950000405311584},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.42829999327659607},{"id":"https://openalex.org/C183121708","wikidata":"https://www.wikidata.org/wiki/Q209867","display_name":"Telemetry","level":2,"score":0.42320001125335693},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.4124999940395355},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.40529999136924744},{"id":"https://openalex.org/C2778012447","wikidata":"https://www.wikidata.org/wiki/Q1034415","display_name":"Scope (computer science)","level":2,"score":0.3813000023365021},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.3806000053882599},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.3783999979496002},{"id":"https://openalex.org/C110875604","wikidata":"https://www.wikidata.org/wiki/Q75","display_name":"The Internet","level":2,"score":0.3756999969482422},{"id":"https://openalex.org/C2780898871","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Performance metric","level":2,"score":0.36730000376701355},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.34549999237060547},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.335099995136261},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3303999900817871},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.32829999923706055},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32179999351501465},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.30869999527931213},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.2888000011444092},{"id":"https://openalex.org/C158207573","wikidata":"https://www.wikidata.org/wiki/Q5747224","display_name":"Heterogeneous network","level":4,"score":0.27469998598098755},{"id":"https://openalex.org/C62793504","wikidata":"https://www.wikidata.org/wiki/Q228327","display_name":"Access network","level":2,"score":0.2648000121116638},{"id":"https://openalex.org/C203274722","wikidata":"https://www.wikidata.org/wiki/Q7001161","display_name":"Network performance","level":2,"score":0.26330000162124634}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iscc65549.2025.11325991","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscc65549.2025.11325991","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Symposium on Computers and Communications (ISCC)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-05030266v1","is_oa":true,"landing_page_url":"https://inria.hal.science/hal-05030266","pdf_url":"https://inria.hal.science/hal-05030266/document","source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISCC 2025 - 30th IEEE Symposium on Computers and Communications, Jul 2025, Bologna, Italy","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:HAL:hal-05030266v1","is_oa":true,"landing_page_url":"https://inria.hal.science/hal-05030266","pdf_url":"https://inria.hal.science/hal-05030266/document","source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISCC 2025 - 30th IEEE Symposium on Computers and Communications, Jul 2025, Bologna, Italy","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G181216750","display_name":"Orchestration and Programming ENergy-aware and collaborative Swarms With AI-powered Reliable Methods","funder_award_id":"101093046","funder_id":"https://openalex.org/F4320320300","funder_display_name":"European Commission"}],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320334322","display_name":"HORIZON EUROPE Framework Programme","ror":null}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4416222898.pdf","grobid_xml":"https://content.openalex.org/works/W4416222898.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Low-power":[0],"wireless":[1],"networks":[2,28],"are":[3],"increasingly":[4],"deployed":[5],"in":[6,56,118,128],"Industrial":[7],"Internet":[8],"of":[9,19,22,126],"Things":[10],"(IIoT)":[11],"environments":[12],"to":[13,36,62,81,85,101],"ensure":[14],"reliable":[15],"and":[16,108,132],"secure":[17],"operation":[18],"machinery.":[20],"One":[21],"the":[23,34,39,119,124],"key":[24],"requirements":[25,104],"for":[26,105],"these":[27],"is":[29],"reliability,":[30],"which":[31,77],"hinges":[32],"on":[33],"ability":[35],"continuously":[37],"assess":[38],"network\u2019s":[40],"health":[41],"a":[42,91],"challenge":[43],"addressed":[44],"by":[45,114],"Application":[46],"Performance":[47],"Monitoring":[48],"(APM).":[49],"Within":[50],"APM,":[51],"transmitting":[52],"performance":[53],"metrics,":[54],"particularly":[55],"low-power":[57],"networks,":[58],"must":[59],"be":[60],"efficient":[61],"preserve":[63],"battery":[64],"life.":[65],"This":[66],"paper":[67],"addresses":[68],"various":[69],"APM":[70],"approaches,":[71],"including":[72],"In-band":[73],"Network":[74],"Telemetry":[75],"(INT),":[76],"leverages":[78],"multi-hop":[79],"topologies":[80],"append":[82],"telemetry":[83,106],"data":[84,133],"existing":[86],"packets.":[87],"We":[88],"propose":[89],"HyPM,":[90],"novel":[92],"hybrid":[93],"method":[94],"that":[95],"combines":[96],"active":[97],"monitoring":[98],"with":[99],"INT":[100],"meet":[102],"user":[103],"scope":[107],"frequency":[109],"while":[110],"improving":[111],"energy":[112,130],"efficiency":[113],"$31":[115],"\\%$.":[116],"Simulations":[117],"Contiki-NG":[120],"network":[121],"simulator":[122],"demonstrate":[123],"superiority":[125],"HyPM":[127],"balancing":[129],"consumption":[131],"reporting":[134],"accuracy.":[135]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
