{"id":"https://openalex.org/W4400231306","doi":"https://doi.org/10.1109/iscas58744.2024.10558169","title":"A 400 MHz Voltage-Mode-Based Fully Integrated Regulating Rectifier for Deep Tissue Bio-implants","display_name":"A 400 MHz Voltage-Mode-Based Fully Integrated Regulating Rectifier for Deep Tissue Bio-implants","publication_year":2024,"publication_date":"2024-05-19","ids":{"openalex":"https://openalex.org/W4400231306","doi":"https://doi.org/10.1109/iscas58744.2024.10558169"},"language":"en","primary_location":{"id":"doi:10.1109/iscas58744.2024.10558169","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas58744.2024.10558169","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE International Symposium on Circuits and Systems (ISCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111012688","display_name":"Guoao Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Guoao Liu","raw_affiliation_strings":["Beihang University,School of Integrated Circuit Science and Engineering,China"],"affiliations":[{"raw_affiliation_string":"Beihang University,School of Integrated Circuit Science and Engineering,China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101698140","display_name":"Yuanqi Hu","orcid":"https://orcid.org/0000-0001-9179-6603"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuanqi Hu","raw_affiliation_strings":["Beihang University,School of Integrated Circuit Science and Engineering,China"],"affiliations":[{"raw_affiliation_string":"Beihang University,School of Integrated Circuit Science and Engineering,China","institution_ids":["https://openalex.org/I82880672"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5111012688"],"corresponding_institution_ids":["https://openalex.org/I82880672"],"apc_list":null,"apc_paid":null,"fwci":0.2095,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.46523381,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9089000225067139,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9089000225067139,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9006999731063843,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5634837746620178},{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.5406882166862488},{"id":"https://openalex.org/keywords/mode","display_name":"Mode (computer interface)","score":0.4585847854614258},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4200237989425659},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.399814635515213},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3892377018928528},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3817846179008484},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.37628328800201416},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.35702770948410034},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24868884682655334},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08828318119049072}],"concepts":[{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5634837746620178},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.5406882166862488},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.4585847854614258},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4200237989425659},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.399814635515213},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3892377018928528},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3817846179008484},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37628328800201416},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.35702770948410034},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24868884682655334},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08828318119049072},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iscas58744.2024.10558169","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas58744.2024.10558169","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE International Symposium on Circuits and Systems (ISCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1967356008","https://openalex.org/W1982987056","https://openalex.org/W2025120427","https://openalex.org/W2043873236","https://openalex.org/W2072076450","https://openalex.org/W2075351013","https://openalex.org/W2110545851","https://openalex.org/W2159742781","https://openalex.org/W2294348344","https://openalex.org/W2747082052","https://openalex.org/W2749313409","https://openalex.org/W2808857108","https://openalex.org/W2913645639","https://openalex.org/W2966566935","https://openalex.org/W2978394926","https://openalex.org/W3048860528","https://openalex.org/W3092278802","https://openalex.org/W4309327403","https://openalex.org/W4360605714"],"related_works":["https://openalex.org/W2007591794","https://openalex.org/W3147271679","https://openalex.org/W2355380179","https://openalex.org/W2086122209","https://openalex.org/W2789304794","https://openalex.org/W2289713407","https://openalex.org/W2068284402","https://openalex.org/W2208779337","https://openalex.org/W2890668042","https://openalex.org/W2767133758"],"abstract_inverted_index":{"In":[0],"this":[1,66],"paper,":[2],"a":[3,70,93],"voltage-mode-based":[4],"fully":[5],"integrated":[6],"resonance":[7],"regulating":[8],"rectifier":[9,67],"(IR<sup":[10],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[11],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">3</sup>)":[12],"running":[13],"at":[14,50],"400":[15],"MHz":[16],"has":[17],"been":[18],"designed":[19,35],"for":[20,40],"wireless":[21],"power":[22,94],"transfer":[23],"(WPT)":[24],"implants":[25],"in":[26],"deep":[27,86],"tissue.":[28],"Separate":[29],"on-&-off":[30],"delay":[31,63],"compensation":[32,59,64],"circuits":[33],"are":[34],"to":[36,77,84],"avoid":[37],"reverse":[38],"current":[39],"efficiency":[41,73,96],"and":[42,61,88],"lower":[43],"ripple":[44],"factor,":[45],"which":[46],"is":[47],"about":[48],"0.28%":[49],"1.8":[51],"V":[52],"regulated":[53],"output":[54],"voltage.":[55],"With":[56],"the":[57,62,79,85,89],"regulation":[58],"circuit":[60],"scheme,":[65],"can":[68],"reach":[69],"voltage":[71],"conversion":[72,95],"(VCE)":[74],"of":[75,98],"1.73":[76],"overcome":[78],"low":[80],"coupling":[81],"coefficient":[82],"due":[83],"implant,":[87],"whole":[90],"system":[91],"achieves":[92],"(PCE)":[97],"67.8%":[99],"with":[100],"2":[101],"mW":[102],"load.":[103]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2025-12-26T23:08:49.675405","created_date":"2025-10-10T00:00:00"}