{"id":"https://openalex.org/W2759737194","doi":"https://doi.org/10.1109/iscas.2017.8050511","title":"Dimensioning and comparison of common compensation topologies for IPT systems","display_name":"Dimensioning and comparison of common compensation topologies for IPT systems","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2759737194","doi":"https://doi.org/10.1109/iscas.2017.8050511","mag":"2759737194"},"language":"en","primary_location":{"id":"doi:10.1109/iscas.2017.8050511","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2017.8050511","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Symposium on Circuits and Systems (ISCAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015599612","display_name":"Martin Trautmann","orcid":null},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Trautmann","raw_affiliation_strings":["Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany","institution_ids":["https://openalex.org/I181369854"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021241761","display_name":"Marius Ohlendorf","orcid":null},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Marius Ohlendorf","raw_affiliation_strings":["Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany","institution_ids":["https://openalex.org/I181369854"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049511635","display_name":"Benedikt Sanftl","orcid":null},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Benedikt Sanftl","raw_affiliation_strings":["Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany","institution_ids":["https://openalex.org/I181369854"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070760948","display_name":"Robert Weigel","orcid":"https://orcid.org/0000-0002-3131-1800"},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Robert Weigel","raw_affiliation_strings":["Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany","institution_ids":["https://openalex.org/I181369854"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019989632","display_name":"Alexander Koelpin","orcid":"https://orcid.org/0000-0002-9071-5661"},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Alexander Koelpin","raw_affiliation_strings":["Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Electronics Engineering, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany","institution_ids":["https://openalex.org/I181369854"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I181369854"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dimensioning","display_name":"Dimensioning","score":0.9767755270004272},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.7956712245941162},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.7847738265991211},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.7279332876205444},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6154043674468994},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.5158861875534058},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.49173620343208313},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4618126153945923},{"id":"https://openalex.org/keywords/maximum-power-transfer-theorem","display_name":"Maximum power transfer theorem","score":0.4589049220085144},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.41288337111473083},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.36662405729293823},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29320263862609863},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.24000751972198486},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.08959150314331055},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07359099388122559}],"concepts":[{"id":"https://openalex.org/C89714869","wikidata":"https://www.wikidata.org/wiki/Q2280470","display_name":"Dimensioning","level":2,"score":0.9767755270004272},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.7956712245941162},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.7847738265991211},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.7279332876205444},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6154043674468994},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.5158861875534058},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.49173620343208313},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4618126153945923},{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.4589049220085144},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41288337111473083},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.36662405729293823},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29320263862609863},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.24000751972198486},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.08959150314331055},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07359099388122559},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iscas.2017.8050511","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2017.8050511","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Symposium on Circuits and Systems (ISCAS)","raw_type":"proceedings-article"},{"id":"pmh:oai:tore.tuhh.de:11420/6558","is_oa":false,"landing_page_url":"http://hdl.handle.net/11420/6558","pdf_url":null,"source":{"id":"https://openalex.org/S4306401751","display_name":"tub.dok (Hamburg University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I884043246","host_organization_name":"Hamburg University of Technology","host_organization_lineage":["https://openalex.org/I884043246"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference Paper"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.550000011920929,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1905482400","https://openalex.org/W1997107053","https://openalex.org/W2080296341","https://openalex.org/W2121020403","https://openalex.org/W2131561725","https://openalex.org/W2139635237","https://openalex.org/W2139885046","https://openalex.org/W2146801576","https://openalex.org/W2156920047","https://openalex.org/W2169111572","https://openalex.org/W2323381144","https://openalex.org/W2434170794","https://openalex.org/W4229976411"],"related_works":["https://openalex.org/W1562131159","https://openalex.org/W2367248359","https://openalex.org/W2379979386","https://openalex.org/W2980301606","https://openalex.org/W2363010132","https://openalex.org/W582258172","https://openalex.org/W1998726547","https://openalex.org/W2372259569","https://openalex.org/W4234886592","https://openalex.org/W4232555700"],"abstract_inverted_index":{"This":[0,53],"paper":[1],"presents":[2],"the":[3,8,25,30,42,56,60,79,98],"dimensioning":[4],"as":[5,7,27,29,91,93],"well":[6,28,92],"comparison":[9],"of":[10,35,48,59,66],"common":[11],"compensation":[12,21,69],"topologies":[13,100],"for":[14,83],"inductive":[15],"power":[16],"transfer":[17],"(IPT)":[18],"systems.":[19],"A":[20],"is":[22,55],"needed":[23],"on":[24],"primary":[26],"secondary":[31],"side.":[32],"It":[33],"consists":[34],"a":[36,46],"capacitor":[37],"(parallel":[38],"or":[39,45],"series)":[40],"in":[41],"simplest":[43],"case":[44],"combination":[47],"reactive":[49],"components":[50],"(like":[51],"LCC).":[52],"work":[54],"first":[57],"compilation":[58],"dimensioning,":[61],"considering":[62],"all":[63],"potential":[64],"combinations":[65],"these":[67],"three":[68],"possibilities.":[70],"The":[71],"five":[72],"most":[73],"promising":[74],"solutions":[75],"are":[76,81,101],"simulated":[77],"and":[78,86,106],"results":[80],"compared":[82,102],"constant":[84],"current-":[85],"voltage-operation":[87],"with":[88],"varying":[89],"loads":[90],"different":[94,99],"coupling":[95],"factors.":[96],"Finally":[97],"by":[103],"selected":[104],"criteria":[105],"evaluated":[107],"accordingly.":[108]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
