{"id":"https://openalex.org/W2039778370","doi":"https://doi.org/10.1109/iscas.2012.6271505","title":"A Hall sensor microsystem with continuous gain calibration using fully integrated references","display_name":"A Hall sensor microsystem with continuous gain calibration using fully integrated references","publication_year":2012,"publication_date":"2012-05-01","ids":{"openalex":"https://openalex.org/W2039778370","doi":"https://doi.org/10.1109/iscas.2012.6271505","mag":"2039778370"},"language":"en","primary_location":{"id":"doi:10.1109/iscas.2012.6271505","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2012.6271505","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Symposium on Circuits and Systems","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://infoscience.epfl.ch/record/183750","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021579126","display_name":"Andrea Ajbl","orcid":null},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Andrea Ajbl","raw_affiliation_strings":["Electronics Laboratory, EPF Lausanne, Lausanne, Switzerland","Electronics Laboratory, EPFL, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronics Laboratory, EPF Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]},{"raw_affiliation_string":"Electronics Laboratory, EPFL, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067613421","display_name":"Marc Pastre","orcid":null},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Marc Pastre","raw_affiliation_strings":["Electronics Laboratory, EPF Lausanne, Lausanne, Switzerland","Electronics Laboratory, EPFL, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronics Laboratory, EPF Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]},{"raw_affiliation_string":"Electronics Laboratory, EPFL, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037002764","display_name":"Maher Kayal","orcid":"https://orcid.org/0000-0001-5962-174X"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Maher Kayal","raw_affiliation_strings":["Electronics Laboratory, EPF Lausanne, Lausanne, Switzerland","Electronics Laboratory, EPFL, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronics Laboratory, EPF Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]},{"raw_affiliation_string":"Electronics Laboratory, EPFL, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.499,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.83972423,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1399","last_page":"1402"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microsystem","display_name":"Microsystem","score":0.9396369457244873},{"id":"https://openalex.org/keywords/preamplifier","display_name":"Preamplifier","score":0.8126703500747681},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.5917789936065674},{"id":"https://openalex.org/keywords/hall-effect-sensor","display_name":"Hall effect sensor","score":0.5460491180419922},{"id":"https://openalex.org/keywords/biasing","display_name":"Biasing","score":0.5447961688041687},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.47652873396873474},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4645547568798065},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4597795605659485},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4203140139579773},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3917781114578247},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3854175806045532},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.29747912287712097},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.23423829674720764},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.1679808795452118},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.10829055309295654}],"concepts":[{"id":"https://openalex.org/C151054161","wikidata":"https://www.wikidata.org/wiki/Q379385","display_name":"Microsystem","level":2,"score":0.9396369457244873},{"id":"https://openalex.org/C14245642","wikidata":"https://www.wikidata.org/wiki/Q399804","display_name":"Preamplifier","level":4,"score":0.8126703500747681},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.5917789936065674},{"id":"https://openalex.org/C107637996","wikidata":"https://www.wikidata.org/wiki/Q1431247","display_name":"Hall effect sensor","level":3,"score":0.5460491180419922},{"id":"https://openalex.org/C20254490","wikidata":"https://www.wikidata.org/wiki/Q719550","display_name":"Biasing","level":3,"score":0.5447961688041687},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.47652873396873474},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4645547568798065},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4597795605659485},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4203140139579773},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3917781114578247},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3854175806045532},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.29747912287712097},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.23423829674720764},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.1679808795452118},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.10829055309295654},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iscas.2012.6271505","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2012.6271505","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Symposium on Circuits and Systems","raw_type":"proceedings-article"},{"id":"pmh:oai:infoscience.epfl.ch:183750","is_oa":true,"landing_page_url":"http://infoscience.epfl.ch/record/183750","pdf_url":null,"source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text"}],"best_oa_location":{"id":"pmh:oai:infoscience.epfl.ch:183750","is_oa":true,"landing_page_url":"http://infoscience.epfl.ch/record/183750","pdf_url":null,"source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8399999737739563,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1901564967","https://openalex.org/W2050321012","https://openalex.org/W2104295662","https://openalex.org/W2105523739","https://openalex.org/W2139801901","https://openalex.org/W2160489724","https://openalex.org/W2178603932","https://openalex.org/W4243374555","https://openalex.org/W6639854632"],"related_works":["https://openalex.org/W2090711137","https://openalex.org/W1973734680","https://openalex.org/W2532423695","https://openalex.org/W1980494175","https://openalex.org/W1988460209","https://openalex.org/W1986634776","https://openalex.org/W2089541377","https://openalex.org/W3130636831","https://openalex.org/W2094461049","https://openalex.org/W1517482417"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3,71],"integrated":[4,17,63],"Hall":[5,21],"sensor":[6,22],"microsystem":[7,47,61],"with":[8,23],"continuous":[9],"gain":[10,57],"calibration":[11],"and":[12,36,39],"a":[13,20,26,30,33,65],"current-mode":[14],"back-end.":[15],"The":[16,42,59],"system":[18],"includes":[19],"internal":[24,37],"biasing,":[25],"fully":[27],"differential":[28],"front-end,":[29],"preamplifier":[31],"chain,":[32],"voltage-to-current":[34],"converter":[35],"voltage":[38],"current":[40],"references.":[41],"main":[43],"feature":[44],"of":[45,73],"this":[46],"is":[48,62],"full":[49],"integration,":[50],"including":[51],"the":[52,56],"references,":[53],"which":[54],"guarantee":[55],"stability.":[58],"whole":[60],"in":[64],"0.35\u00b5m":[66],"CMOS":[67],"technology.":[68],"It":[69],"occupies":[70],"area":[72],"11.55mm":[74],"<sup":[75],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[76],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">2</sup>":[77],".":[78]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":3}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
