{"id":"https://openalex.org/W2109833922","doi":"https://doi.org/10.1109/iscas.2008.4541759","title":"Address compression for scalable load/store queue implementation","display_name":"Address compression for scalable load/store queue implementation","publication_year":2008,"publication_date":"2008-05-01","ids":{"openalex":"https://openalex.org/W2109833922","doi":"https://doi.org/10.1109/iscas.2008.4541759","mag":"2109833922"},"language":"en","primary_location":{"id":"doi:10.1109/iscas.2008.4541759","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2008.4541759","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 IEEE International Symposium on Circuits and Systems (ISCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081983150","display_name":"Yi-Ying Tsai","orcid":null},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Yi-Ying Tsai","raw_affiliation_strings":["Department of Electrical Engineering and Institute of Computer and Communication Engineering, National Cheng Kung University, Tainan, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Institute of Computer and Communication Engineering, National Cheng Kung University, Tainan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030513018","display_name":"Chia\u2010Jung Hsu","orcid":"https://orcid.org/0000-0001-9932-7713"},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Chia-Jung Hsu","raw_affiliation_strings":["Department of Electrical Engineering and Institute of Computer and Communication Engineering, National Cheng Kung University, Tainan, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Institute of Computer and Communication Engineering, National Cheng Kung University, Tainan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111582905","display_name":"Chung\u2010Ho Chen","orcid":null},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Chung-Ho Chen","raw_affiliation_strings":["Department of Electrical Engineering and Institute of Computer and Communication Engineering, National Cheng Kung University, Tainan, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Institute of Computer and Communication Engineering, National Cheng Kung University, Tainan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.09911611,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1680","last_page":"1683"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.8387041091918945},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8233532309532166},{"id":"https://openalex.org/keywords/queue","display_name":"Queue","score":0.7770518064498901},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6456915140151978},{"id":"https://openalex.org/keywords/ranging","display_name":"Ranging","score":0.5833431482315063},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.4904899299144745},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4783187210559845},{"id":"https://openalex.org/keywords/reduction","display_name":"Reduction (mathematics)","score":0.4514264166355133},{"id":"https://openalex.org/keywords/parallel-computing","display_name":"Parallel computing","score":0.42476266622543335},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.38853058218955994},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.32709163427352905},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3225333094596863},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3206825256347656},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.2359515130519867},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.19307100772857666},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.07028856873512268},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.06595942378044128}],"concepts":[{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.8387041091918945},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8233532309532166},{"id":"https://openalex.org/C160403385","wikidata":"https://www.wikidata.org/wiki/Q220543","display_name":"Queue","level":2,"score":0.7770518064498901},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6456915140151978},{"id":"https://openalex.org/C115051666","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Ranging","level":2,"score":0.5833431482315063},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.4904899299144745},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4783187210559845},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.4514264166355133},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.42476266622543335},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.38853058218955994},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.32709163427352905},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3225333094596863},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3206825256347656},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2359515130519867},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.19307100772857666},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.07028856873512268},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.06595942378044128},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iscas.2008.4541759","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2008.4541759","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 IEEE International Symposium on Circuits and Systems (ISCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W118432253","https://openalex.org/W2032094184","https://openalex.org/W2062143991","https://openalex.org/W2100466074","https://openalex.org/W2102727118","https://openalex.org/W2104593972","https://openalex.org/W2160401437","https://openalex.org/W3140903683","https://openalex.org/W4239503669","https://openalex.org/W6604812262","https://openalex.org/W6792941224"],"related_works":["https://openalex.org/W2783354812","https://openalex.org/W4384112194","https://openalex.org/W2103009189","https://openalex.org/W4312958259","https://openalex.org/W4308259661","https://openalex.org/W4390813131","https://openalex.org/W2349383066","https://openalex.org/W4328132048","https://openalex.org/W1969901537","https://openalex.org/W179829755"],"abstract_inverted_index":{"Contemporary":[0],"superscalar":[1],"processors":[2],"employ":[3],"the":[4,22,49,55,58,62,80],"load/store":[5,11,45],"queue":[6,12,46],"for":[7,24,44],"memory":[8],"disambiguation.":[9],"A":[10],"is":[13],"typically":[14],"implemented":[15],"with":[16],"a":[17,102],"CAM":[18],"structure":[19],"to":[20,47,68,76],"search":[21],"address":[23,41],"collision":[25],"and":[26,34,52,70,83,95],"consequently":[27],"poses":[28],"scalability":[29],"challenges":[30],"of":[31],"energy":[32,63,93],"consumption":[33,64],"area":[35,71],"cost.":[36],"This":[37],"paper":[38],"proposes":[39],"an":[40],"compression":[42,81],"technique":[43],"improve":[48],"power":[50],"efficiency":[51],"scalability.":[53],"Using":[54],"proposed":[56],"approach,":[57],"LSQ":[59],"can":[60,88],"reduce":[61],"ranging":[65,73],"from":[66,74],"38%":[67],"72%":[69],"cost":[72],"32%":[75],"66%,":[77],"depending":[78],"on":[79],"parameter":[82],"system":[84],"configuration.":[85,104],"The":[86],"approach":[87],"provide":[89],"3.08%":[90],"overall":[91],"processor":[92],"reduction":[94],"causes":[96],"only":[97],"0.22%":[98],"performance":[99],"loss":[100],"at":[101],"balanced":[103]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
