{"id":"https://openalex.org/W2529704446","doi":"https://doi.org/10.1109/isc2.2016.7580879","title":"Outage response in microgrids using demand side management","display_name":"Outage response in microgrids using demand side management","publication_year":2016,"publication_date":"2016-09-01","ids":{"openalex":"https://openalex.org/W2529704446","doi":"https://doi.org/10.1109/isc2.2016.7580879","mag":"2529704446"},"language":"en","primary_location":{"id":"doi:10.1109/isc2.2016.7580879","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isc2.2016.7580879","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Smart Cities Conference (ISC2)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5007417780","display_name":"Sandford Bessler","orcid":null},"institutions":[{"id":"https://openalex.org/I132118926","display_name":"Austrian Institute of Technology","ror":"https://ror.org/04knbh022","country_code":"AT","type":"facility","lineage":["https://openalex.org/I132118926"]}],"countries":["AT"],"is_corresponding":true,"raw_author_name":"Sandford Bessler","raw_affiliation_strings":["AIT Austrian Institute of Technology, Vienna, Austria"],"affiliations":[{"raw_affiliation_string":"AIT Austrian Institute of Technology, Vienna, Austria","institution_ids":["https://openalex.org/I132118926"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082604631","display_name":"Daniel Hovie","orcid":null},"institutions":[{"id":"https://openalex.org/I132118926","display_name":"Austrian Institute of Technology","ror":"https://ror.org/04knbh022","country_code":"AT","type":"facility","lineage":["https://openalex.org/I132118926"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Daniel Hovie","raw_affiliation_strings":["AIT Austrian Institute of Technology, Vienna, Austria"],"affiliations":[{"raw_affiliation_string":"AIT Austrian Institute of Technology, Vienna, Austria","institution_ids":["https://openalex.org/I132118926"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071769322","display_name":"Oliver Jung","orcid":"https://orcid.org/0000-0003-0483-1605"},"institutions":[{"id":"https://openalex.org/I132118926","display_name":"Austrian Institute of Technology","ror":"https://ror.org/04knbh022","country_code":"AT","type":"facility","lineage":["https://openalex.org/I132118926"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Oliver Jung","raw_affiliation_strings":["AIT Austrian Institute of Technology, Vienna, Austria"],"affiliations":[{"raw_affiliation_string":"AIT Austrian Institute of Technology, Vienna, Austria","institution_ids":["https://openalex.org/I132118926"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5007417780"],"corresponding_institution_ids":["https://openalex.org/I132118926"],"apc_list":null,"apc_paid":null,"fwci":0.2678,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.60498753,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/demand-side","display_name":"Demand side","score":0.7323877811431885},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.6649226546287537},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5519503951072693},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.4690347909927368},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.37491095066070557},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1570858359336853},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14719003438949585},{"id":"https://openalex.org/keywords/environmental-economics","display_name":"Environmental economics","score":0.10802996158599854},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.06860029697418213},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.06629225611686707}],"concepts":[{"id":"https://openalex.org/C3020254827","wikidata":"https://www.wikidata.org/wiki/Q5255016","display_name":"Demand side","level":2,"score":0.7323877811431885},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.6649226546287537},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5519503951072693},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.4690347909927368},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.37491095066070557},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1570858359336853},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14719003438949585},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.10802996158599854},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.06860029697418213},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.06629225611686707}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isc2.2016.7580879","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isc2.2016.7580879","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Smart Cities Conference (ISC2)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.550000011920929,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1928473796","https://openalex.org/W1970181869","https://openalex.org/W2000920265","https://openalex.org/W2001965107","https://openalex.org/W2078926545","https://openalex.org/W2080048739","https://openalex.org/W2089635373","https://openalex.org/W2117685617","https://openalex.org/W2158119364","https://openalex.org/W2336258345","https://openalex.org/W2564015532","https://openalex.org/W6731281820"],"related_works":["https://openalex.org/W2173475281","https://openalex.org/W2035833777","https://openalex.org/W2392147676","https://openalex.org/W2522559011","https://openalex.org/W1589973774","https://openalex.org/W4307686474","https://openalex.org/W2358791272","https://openalex.org/W3135272596","https://openalex.org/W2072325519","https://openalex.org/W2805081846"],"abstract_inverted_index":{"The":[0],"reliability":[1],"of":[2,85],"the":[3,29,37,44,55,82,89,99],"power":[4,31],"supply":[5],"is":[6],"increasingly":[7],"threatened":[8],"both":[9],"by":[10,25,88],"natural":[11],"catastrophes":[12],"(such":[13],"as":[14],"floods,":[15],"drought,":[16],"storms,":[17],"etc.)":[18],"due":[19],"to":[20,35,39],"climate":[21],"change":[22],"effects":[23],"and":[24,62,72,77],"cyber":[26],"attacks":[27],"on":[28],"connected":[30],"grid.":[32],"In":[33],"order":[34],"study":[36],"response":[38],"an":[40,92],"outage,":[41,93],"we":[42,80],"address":[43],"problem":[45],"in":[46,57,95],"a":[47,52,68,73,96],"bottom-up":[48],"manner,":[49],"starting":[50],"from":[51],"small":[53],"entity,":[54],"microgrid,":[56],"which":[58],"renewable":[59],"generation,":[60],"storage":[61],"flexible":[63],"loads":[64],"are":[65],"modeled.":[66],"Using":[67],"demand":[69],"management":[70],"scheme":[71],"classification":[74],"into":[75],"critical":[76],"interruptible":[78],"demand,":[79],"investigate":[81],"remaining":[83],"amount":[84],"energy":[86],"required":[87],"microgrid":[90],"during":[91],"reflected":[94],"new":[97],"metric,":[98],"\u201cgrid":[100],"autonomy":[101],"factor\u201d.":[102]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
