{"id":"https://openalex.org/W4224999588","doi":"https://doi.org/10.1109/isbi52829.2022.9761480","title":"Extending the Capability of Linear Array Ultrasound Probe to Concave Array Using Low-Cost Acoustic Lens for High Frame Rate Focused Imaging","display_name":"Extending the Capability of Linear Array Ultrasound Probe to Concave Array Using Low-Cost Acoustic Lens for High Frame Rate Focused Imaging","publication_year":2022,"publication_date":"2022-03-28","ids":{"openalex":"https://openalex.org/W4224999588","doi":"https://doi.org/10.1109/isbi52829.2022.9761480"},"language":"en","primary_location":{"id":"doi:10.1109/isbi52829.2022.9761480","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isbi52829.2022.9761480","pdf_url":null,"source":{"id":"https://openalex.org/S4363605129","display_name":"2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024959280","display_name":"Pisharody Harikrishnan Gopalakrishnan","orcid":"https://orcid.org/0000-0001-7796-6645"},"institutions":[{"id":"https://openalex.org/I4210113248","display_name":"Indian Institute of Technology Palakkad","ror":"https://ror.org/0264cg909","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210113248"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Pisharody Harikrishnan Gopalakrishnan","raw_affiliation_strings":["Indian Institute of Technology,Center for Computational Imaging,Palakkad","Center for Computational Imaging, Indian Institute of Technology, Palakkad"],"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Center for Computational Imaging,Palakkad","institution_ids":["https://openalex.org/I4210113248"]},{"raw_affiliation_string":"Center for Computational Imaging, Indian Institute of Technology, Palakkad","institution_ids":["https://openalex.org/I4210113248"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004554734","display_name":"Mahesh Raveendranatha Panicker","orcid":"https://orcid.org/0000-0001-5273-0732"},"institutions":[{"id":"https://openalex.org/I4210113248","display_name":"Indian Institute of Technology Palakkad","ror":"https://ror.org/0264cg909","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210113248"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Mahesh Raveendranatha Panicker","raw_affiliation_strings":["Indian Institute of Technology,Center for Computational Imaging,Palakkad","Center for Computational Imaging, Indian Institute of Technology, Palakkad"],"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Center for Computational Imaging,Palakkad","institution_ids":["https://openalex.org/I4210113248"]},{"raw_affiliation_string":"Center for Computational Imaging, Indian Institute of Technology, Palakkad","institution_ids":["https://openalex.org/I4210113248"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5024959280"],"corresponding_institution_ids":["https://openalex.org/I4210113248"],"apc_list":null,"apc_paid":null,"fwci":0.6413,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.57679541,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":96},"biblio":{"volume":"15","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10727","display_name":"Ultrasound Imaging and Elastography","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10958","display_name":"Ultrasound and Hyperthermia Applications","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.7901865243911743},{"id":"https://openalex.org/keywords/frame-rate","display_name":"Frame rate","score":0.664427638053894},{"id":"https://openalex.org/keywords/lens","display_name":"Lens (geology)","score":0.6315514445304871},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5666342973709106},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.5391948223114014},{"id":"https://openalex.org/keywords/ultrasound","display_name":"Ultrasound","score":0.5300486087799072},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.5265905261039734},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5242783427238464},{"id":"https://openalex.org/keywords/depth-of-field","display_name":"Depth of field","score":0.4816409647464752},{"id":"https://openalex.org/keywords/plane-wave","display_name":"Plane wave","score":0.4438202977180481},{"id":"https://openalex.org/keywords/image-resolution","display_name":"Image resolution","score":0.4345559775829315},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.38931524753570557},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3646763563156128},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.18037483096122742},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.11303889751434326}],"concepts":[{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.7901865243911743},{"id":"https://openalex.org/C3261483","wikidata":"https://www.wikidata.org/wiki/Q119565","display_name":"Frame rate","level":2,"score":0.664427638053894},{"id":"https://openalex.org/C15336307","wikidata":"https://www.wikidata.org/wiki/Q1766051","display_name":"Lens (geology)","level":2,"score":0.6315514445304871},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5666342973709106},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.5391948223114014},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.5300486087799072},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.5265905261039734},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5242783427238464},{"id":"https://openalex.org/C183072630","wikidata":"https://www.wikidata.org/wiki/Q215932","display_name":"Depth of field","level":2,"score":0.4816409647464752},{"id":"https://openalex.org/C40308292","wikidata":"https://www.wikidata.org/wiki/Q122518","display_name":"Plane wave","level":2,"score":0.4438202977180481},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.4345559775829315},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.38931524753570557},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3646763563156128},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18037483096122742},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.11303889751434326}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isbi52829.2022.9761480","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isbi52829.2022.9761480","pdf_url":null,"source":{"id":"https://openalex.org/S4363605129","display_name":"2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320334771","display_name":"Science and Engineering Research Board","ror":"https://ror.org/03ffdsr55"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W392719047","https://openalex.org/W598735987","https://openalex.org/W1966291038","https://openalex.org/W2023118974","https://openalex.org/W2045549635","https://openalex.org/W2089092965","https://openalex.org/W2096932028","https://openalex.org/W2101507650","https://openalex.org/W2126076379","https://openalex.org/W2162473564","https://openalex.org/W2476980478","https://openalex.org/W2765877248","https://openalex.org/W2784815005","https://openalex.org/W6824177049"],"related_works":["https://openalex.org/W2012283803","https://openalex.org/W4384820447","https://openalex.org/W2072454424","https://openalex.org/W2117438306","https://openalex.org/W2185942010","https://openalex.org/W2260725127","https://openalex.org/W3014267290","https://openalex.org/W2135082998","https://openalex.org/W3082525643","https://openalex.org/W2547280774"],"abstract_inverted_index":{"In":[0,40,61],"the":[1,42,53,125],"current":[2],"scenario":[3],"medical":[4],"practitioners":[5],"use":[6],"different":[7,16],"types":[8],"of":[9,22,58,130,146],"transducer":[10,80],"probes":[11,34],"for":[12,29,37,75],"imaging":[13,31,96],"organs":[14],"at":[15],"depths":[17],"and":[18,108,127,133,150],"with":[19,82,105,112],"varying":[20],"field":[21],"view.":[23],"Normally":[24],"linear":[25,78],"arrays":[26],"are":[27,35],"used":[28,36],"near-field":[30],"while":[32],"convex":[33],"far-field":[38],"imaging.":[39],"both":[41],"cases,":[43],"focusing":[44],"is":[45,97],"achieved":[46],"through":[47],"electronics":[48],"delays,":[49],"which":[50,137],"will":[51],"reduce":[52],"frame":[54],"rate":[55],"to":[56,86,90],"maximum":[57],"50":[59],"fps.":[60],"this":[62],"work,":[63],"an":[64,122],"approach":[65],"towards":[66],"a":[67,77,87],"low-cost":[68],"setup":[69],"using":[70,140],"gel":[71],"based":[72],"acoustic":[73],"lens":[74],"converting":[76],"array":[79,89],"probe":[81],"plane":[83],"wave":[84],"transmission":[85],"concave":[88],"induce":[91],"focused":[92],"ultrasound":[93],"(US)":[94],"B-Mode":[95],"attempted.":[98],"Results":[99],"from":[100],"Simulation,":[101],"in":[102,109,124],"vitro":[103],"experiments":[104,111],"pin":[106],"phantoms":[107],"vivo":[110],"human":[113],"carotid":[114],"showed":[115],"promising":[116],"results.":[117],"The":[118],"experimental":[119],"results":[120,142],"yielded":[121],"improvement":[123],"lateral":[126,149],"axial":[128,153],"resolution":[129],"36.67":[131],"%":[132,135,148,152],"28.57":[134],"respectively":[136],"were":[138],"pre-validated":[139],"simulation":[141],"yielding":[143],"similar":[144],"outcomes":[145],"47.50":[147],"33.33":[151],"resolution.":[154]},"counts_by_year":[{"year":2025,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}