{"id":"https://openalex.org/W1568009607","doi":"https://doi.org/10.1109/isbi.2015.7164013","title":"Rapid free-breathing dynamic contrast-enhanced MRI using motion-resolved compressed sensing","display_name":"Rapid free-breathing dynamic contrast-enhanced MRI using motion-resolved compressed sensing","publication_year":2015,"publication_date":"2015-04-01","ids":{"openalex":"https://openalex.org/W1568009607","doi":"https://doi.org/10.1109/isbi.2015.7164013","mag":"1568009607"},"language":"en","primary_location":{"id":"doi:10.1109/isbi.2015.7164013","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isbi.2015.7164013","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100777232","display_name":"Li Feng","orcid":"https://orcid.org/0000-0002-8692-7645"},"institutions":[{"id":"https://openalex.org/I4210153792","display_name":"University School","ror":"https://ror.org/05ap66461","country_code":"US","type":"education","lineage":["https://openalex.org/I4210153792"]},{"id":"https://openalex.org/I57206974","display_name":"New York University","ror":"https://ror.org/0190ak572","country_code":"US","type":"education","lineage":["https://openalex.org/I57206974"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Li Feng","raw_affiliation_strings":["New York University School of Medicine, New York, NY, US","Center for Advanced Imaging Innovation and Research (CAIR) Department of Radiology, New York University School of Medicine, New York, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"New York University School of Medicine, New York, NY, US","institution_ids":["https://openalex.org/I4210153792","https://openalex.org/I57206974"]},{"raw_affiliation_string":"Center for Advanced Imaging Innovation and Research (CAIR) Department of Radiology, New York University School of Medicine, New York, NY, USA","institution_ids":["https://openalex.org/I57206974"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009380657","display_name":"Daniel K. Sodickson","orcid":"https://orcid.org/0000-0002-2436-4664"},"institutions":[{"id":"https://openalex.org/I4210153792","display_name":"University School","ror":"https://ror.org/05ap66461","country_code":"US","type":"education","lineage":["https://openalex.org/I4210153792"]},{"id":"https://openalex.org/I57206974","display_name":"New York University","ror":"https://ror.org/0190ak572","country_code":"US","type":"education","lineage":["https://openalex.org/I57206974"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Daniel K Sodickson","raw_affiliation_strings":["New York University School of Medicine, New York, NY, US","Center for Advanced Imaging Innovation and Research (CAIR) Department of Radiology, New York University School of Medicine, New York, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"New York University School of Medicine, New York, NY, US","institution_ids":["https://openalex.org/I4210153792","https://openalex.org/I57206974"]},{"raw_affiliation_string":"Center for Advanced Imaging Innovation and Research (CAIR) Department of Radiology, New York University School of Medicine, New York, NY, USA","institution_ids":["https://openalex.org/I57206974"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5064366661","display_name":"Ricardo Otazo","orcid":"https://orcid.org/0000-0002-3782-4930"},"institutions":[{"id":"https://openalex.org/I4210153792","display_name":"University School","ror":"https://ror.org/05ap66461","country_code":"US","type":"education","lineage":["https://openalex.org/I4210153792"]},{"id":"https://openalex.org/I57206974","display_name":"New York University","ror":"https://ror.org/0190ak572","country_code":"US","type":"education","lineage":["https://openalex.org/I57206974"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ricardo Otazo","raw_affiliation_strings":["New York University School of Medicine, New York, NY, US","Center for Advanced Imaging Innovation and Research (CAIR) Department of Radiology, New York University School of Medicine, New York, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"New York University School of Medicine, New York, NY, US","institution_ids":["https://openalex.org/I4210153792","https://openalex.org/I57206974"]},{"raw_affiliation_string":"Center for Advanced Imaging Innovation and Research (CAIR) Department of Radiology, New York University School of Medicine, New York, NY, USA","institution_ids":["https://openalex.org/I57206974"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6851,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.6360671,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"889","last_page":"892"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10522","display_name":"Medical Imaging Techniques and Applications","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/compressed-sensing","display_name":"Compressed sensing","score":0.8807491064071655},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.67778480052948},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.6629927158355713},{"id":"https://openalex.org/keywords/grasp","display_name":"GRASP","score":0.5994706749916077},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.5953147411346436},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.5770208239555359},{"id":"https://openalex.org/keywords/contrast","display_name":"Contrast (vision)","score":0.5119658708572388},{"id":"https://openalex.org/keywords/iterative-reconstruction","display_name":"Iterative reconstruction","score":0.47781068086624146},{"id":"https://openalex.org/keywords/dynamic-contrast-enhanced-mri","display_name":"Dynamic contrast-enhanced MRI","score":0.4737611413002014},{"id":"https://openalex.org/keywords/motion","display_name":"Motion (physics)","score":0.4563676714897156},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.07142126560211182},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.06080782413482666}],"concepts":[{"id":"https://openalex.org/C124851039","wikidata":"https://www.wikidata.org/wiki/Q2665459","display_name":"Compressed sensing","level":2,"score":0.8807491064071655},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.67778480052948},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.6629927158355713},{"id":"https://openalex.org/C171268870","wikidata":"https://www.wikidata.org/wiki/Q1486676","display_name":"GRASP","level":2,"score":0.5994706749916077},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.5953147411346436},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.5770208239555359},{"id":"https://openalex.org/C2776502983","wikidata":"https://www.wikidata.org/wiki/Q690182","display_name":"Contrast (vision)","level":2,"score":0.5119658708572388},{"id":"https://openalex.org/C141379421","wikidata":"https://www.wikidata.org/wiki/Q6094427","display_name":"Iterative reconstruction","level":2,"score":0.47781068086624146},{"id":"https://openalex.org/C41727105","wikidata":"https://www.wikidata.org/wiki/Q17009718","display_name":"Dynamic contrast-enhanced MRI","level":3,"score":0.4737611413002014},{"id":"https://openalex.org/C104114177","wikidata":"https://www.wikidata.org/wiki/Q79782","display_name":"Motion (physics)","level":2,"score":0.4563676714897156},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.07142126560211182},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.06080782413482666},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isbi.2015.7164013","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isbi.2015.7164013","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1482297123","https://openalex.org/W1520664974","https://openalex.org/W1979954835","https://openalex.org/W2014989488","https://openalex.org/W2091719438","https://openalex.org/W2099944953","https://openalex.org/W2101675075","https://openalex.org/W2145096794","https://openalex.org/W2161061318","https://openalex.org/W2167227980","https://openalex.org/W2167233877","https://openalex.org/W2169340230","https://openalex.org/W2296616510","https://openalex.org/W4249760698","https://openalex.org/W4250955649"],"related_works":["https://openalex.org/W2163296013","https://openalex.org/W2743859443","https://openalex.org/W2326995835","https://openalex.org/W165915117","https://openalex.org/W2059402478","https://openalex.org/W2123347777","https://openalex.org/W2896778670","https://openalex.org/W2030107647","https://openalex.org/W1526570822","https://openalex.org/W2403497916"],"abstract_inverted_index":{"Compressed":[0],"sensing":[1,48,92],"is":[2],"a":[3,26,39,89],"powerful":[4],"rapid":[5],"imaging":[6,86],"approach":[7],"for":[8,49],"Magnetic":[9],"Resonance":[10],"Imaging":[11],"(MRI)":[12],"and":[13,87,100,108],"has":[14],"been":[15],"applied":[16],"to":[17,33,94,111],"many":[18],"clinical":[19,123],"applications.":[20],"In":[21,35],"this":[22],"work,":[23],"we":[24,37],"propose":[25],"new":[27],"use":[28],"of":[29,42,84,122],"sparsity":[30,96],"in":[31],"addition":[32],"speed.":[34],"particular,":[36],"present":[38],"novel":[40],"way":[41],"handling":[43],"respiratory":[44,77,101,113],"motion":[45,78,102,114],"using":[46,80],"compressed":[47,91],"dynamic":[50],"contrast-enhanced":[51],"MRI.":[52],"The":[53],"proposed":[54],"technique,":[55],"called":[56],"XD-GRASP":[57,104],"(eXtra-Dimensional":[58],"Golden-angle":[59],"RAdial":[60],"Sparse":[61],"Parallel":[62],"MRI),":[63],"sorts":[64],"the":[65,81],"continuously":[66],"acquired":[67],"radial":[68,85],"k-space":[69],"data":[70],"into":[71],"undersampled":[72],"contrast":[73,116],"phases":[74],"at":[75],"multiple":[76],"states":[79],"self-navigation":[82],"properties":[83],"employs":[88],"multidimensional":[90],"reconstruction":[93],"exploit":[95],"along":[97],"both":[98],"contrast-enhancement":[99],"dimensions.":[103],"improves":[105],"image":[106],"quality":[107],"also":[109],"enables":[110],"track":[112],"during":[115],"enhancement,":[117],"which":[118],"can":[119],"potentially":[120],"be":[121],"value.":[124]},"counts_by_year":[{"year":2018,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
