{"id":"https://openalex.org/W2098140220","doi":"https://doi.org/10.1109/isbi.2008.4541171","title":"Dynamic-parallel MR image reconstruction based on adaptive coil sensitivity estimation","display_name":"Dynamic-parallel MR image reconstruction based on adaptive coil sensitivity estimation","publication_year":2008,"publication_date":"2008-05-01","ids":{"openalex":"https://openalex.org/W2098140220","doi":"https://doi.org/10.1109/isbi.2008.4541171","mag":"2098140220"},"language":"en","primary_location":{"id":"doi:10.1109/isbi.2008.4541171","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isbi.2008.4541171","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100349835","display_name":"Ke Liu","orcid":"https://orcid.org/0000-0001-8151-4326"},"institutions":[{"id":"https://openalex.org/I56590836","display_name":"Monash University","ror":"https://ror.org/02bfwt286","country_code":"AU","type":"education","lineage":["https://openalex.org/I56590836"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Ke Liu","raw_affiliation_strings":["Department of Electrical & Computer Systems Engineering, Monash University, Melbourne, VIC, Australia","Dept. of Electr. & Comput. Syst. Eng., Monash Univ., Melbourne, VIC"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical & Computer Systems Engineering, Monash University, Melbourne, VIC, Australia","institution_ids":["https://openalex.org/I56590836"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Syst. Eng., Monash Univ., Melbourne, VIC","institution_ids":["https://openalex.org/I56590836"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100630363","display_name":"Jingxin Zhang","orcid":"https://orcid.org/0000-0002-9450-188X"},"institutions":[{"id":"https://openalex.org/I56590836","display_name":"Monash University","ror":"https://ror.org/02bfwt286","country_code":"AU","type":"education","lineage":["https://openalex.org/I56590836"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Jingxin Zhang","raw_affiliation_strings":["Department of Electrical & Computer Systems Engineering, Monash University, Melbourne, VIC, Australia","Dept. of Electr. & Comput. Syst. Eng., Monash Univ., Melbourne, VIC"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical & Computer Systems Engineering, Monash University, Melbourne, VIC, Australia","institution_ids":["https://openalex.org/I56590836"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Syst. Eng., Monash Univ., Melbourne, VIC","institution_ids":["https://openalex.org/I56590836"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I56590836"],"apc_list":null,"apc_paid":null,"fwci":0.2585,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.66932674,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1015","last_page":"1018"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10500","display_name":"Sparse and Compressive Sensing Techniques","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10522","display_name":"Medical Imaging Techniques and Applications","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.7645142674446106},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7566758394241333},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.6571558713912964},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.6378850340843201},{"id":"https://openalex.org/keywords/iterative-reconstruction","display_name":"Iterative reconstruction","score":0.567710280418396},{"id":"https://openalex.org/keywords/frame","display_name":"Frame (networking)","score":0.5329908728599548},{"id":"https://openalex.org/keywords/real-time-mri","display_name":"Real-time MRI","score":0.5265324711799622},{"id":"https://openalex.org/keywords/frame-rate","display_name":"Frame rate","score":0.4964318871498108},{"id":"https://openalex.org/keywords/image-quality","display_name":"Image quality","score":0.44139763712882996},{"id":"https://openalex.org/keywords/image","display_name":"Image (mathematics)","score":0.34072935581207275},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.3049392104148865}],"concepts":[{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7645142674446106},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7566758394241333},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.6571558713912964},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.6378850340843201},{"id":"https://openalex.org/C141379421","wikidata":"https://www.wikidata.org/wiki/Q6094427","display_name":"Iterative reconstruction","level":2,"score":0.567710280418396},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.5329908728599548},{"id":"https://openalex.org/C157787499","wikidata":"https://www.wikidata.org/wiki/Q13479657","display_name":"Real-time MRI","level":3,"score":0.5265324711799622},{"id":"https://openalex.org/C3261483","wikidata":"https://www.wikidata.org/wiki/Q119565","display_name":"Frame rate","level":2,"score":0.4964318871498108},{"id":"https://openalex.org/C55020928","wikidata":"https://www.wikidata.org/wiki/Q3813865","display_name":"Image quality","level":3,"score":0.44139763712882996},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.34072935581207275},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.3049392104148865},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isbi.2008.4541171","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isbi.2008.4541171","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W633754876","https://openalex.org/W2017051972","https://openalex.org/W2081889156","https://openalex.org/W2082580315","https://openalex.org/W2111161580","https://openalex.org/W2155268695","https://openalex.org/W2167233877","https://openalex.org/W4249760698"],"related_works":["https://openalex.org/W2951714568","https://openalex.org/W2977517636","https://openalex.org/W1988158806","https://openalex.org/W1963814553","https://openalex.org/W2037595954","https://openalex.org/W2507293823","https://openalex.org/W2386146599","https://openalex.org/W2018015402","https://openalex.org/W1995070803","https://openalex.org/W2937242024"],"abstract_inverted_index":{"Imaging":[0,8],"speed":[1],"is":[2,55,101],"crucial":[3],"to":[4,57,84,93,103],"dynamic":[5],"Magnetic":[6],"Resonance":[7],"(dMRI)":[9],"where":[10],"multiple":[11],"images":[12],"must":[13],"be":[14,26],"obtained":[15],"in":[16,72],"a":[17],"single":[18],"examination.":[19],"To":[20],"accelerate":[21],"imaging":[22],"speed,":[23],"dMRI":[24],"can":[25,68],"performed":[27],"with":[28,59],"parallel":[29],"MRI":[30,124],"(pMRI)":[31],"technique":[32],"by":[33],"sparsely":[34],"sampling":[35],"the":[36,60,73,86,95,105,113,128,133,136],"k-space":[37,90,107],"of":[38,48,51,65,89,135],"each":[39,109],"time":[40,114],"frame.":[41],"However,":[42],"pMRI":[43],"reconstruction":[44],"requires":[45],"precise":[46],"estimation":[47,64,82],"sensitivity":[49,66,81,116],"maps":[50,67,117],"receiving":[52],"coils,":[53],"which":[54,112],"difficult":[56],"obtain":[58],"existing":[61],"methods.":[62],"Imperfect":[63],"dramatically":[69],"increase":[70],"artifacts":[71],"reconstructed":[74,137],"image.":[75],"This":[76],"paper":[77],"proposes":[78],"an":[79],"adaptive":[80],"method":[83,130],"capture":[85],"temporal":[87],"variation":[88],"frames":[91],"and":[92],"estimate":[94],"unacquired":[96],"dataset.":[97],"The":[98],"estimated":[99],"dataset":[100],"used":[102],"create":[104],"full":[106],"for":[108],"frame,":[110],"from":[111],"varying":[115],"are":[118],"estimated.":[119],"Experiments":[120],"on":[121],"real":[122],"dynamic-parallel":[123],"data":[125],"demonstrate":[126],"that":[127],"proposed":[129],"significantly":[131],"improves":[132],"quality":[134],"MR":[138],"images.":[139]},"counts_by_year":[{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
