{"id":"https://openalex.org/W4405785732","doi":"https://doi.org/10.1109/iros58592.2024.10802388","title":"Towards Electricity-free Pneumatic Miniature Rotation Actuator for Optical Coherence Tomography Endoscopy","display_name":"Towards Electricity-free Pneumatic Miniature Rotation Actuator for Optical Coherence Tomography Endoscopy","publication_year":2024,"publication_date":"2024-10-14","ids":{"openalex":"https://openalex.org/W4405785732","doi":"https://doi.org/10.1109/iros58592.2024.10802388"},"language":"en","primary_location":{"id":"doi:10.1109/iros58592.2024.10802388","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iros58592.2024.10802388","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5035368566","display_name":"Tinghua Zhang","orcid":"https://orcid.org/0000-0001-8559-4458"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Tinghua Zhang","raw_affiliation_strings":["The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062880935","display_name":"Sishen Yuan","orcid":"https://orcid.org/0000-0001-5095-5372"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Sishen Yuan","raw_affiliation_strings":["The Chinese University of Hong Kong,Department of Electronic Engineering,Hong Kong"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong,Department of Electronic Engineering,Hong Kong","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102711393","display_name":"Chao Xu","orcid":"https://orcid.org/0000-0001-8096-7489"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chao Xu","raw_affiliation_strings":["The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100346745","display_name":"Peng Liu","orcid":"https://orcid.org/0000-0001-6363-5589"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Peng Liu","raw_affiliation_strings":["The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032340829","display_name":"Hongliang Ren","orcid":"https://orcid.org/0000-0002-6488-1551"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongliang Ren","raw_affiliation_strings":["The Chinese University of Hong Kong,Department of Electronic Engineering,Hong Kong"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong,Department of Electronic Engineering,Hong Kong","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037528233","display_name":"Wu Yuan","orcid":"https://orcid.org/0000-0001-9405-519X"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wu Yuan","raw_affiliation_strings":["The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong,Department of Biomedical Engineering,Hong Kong","institution_ids":["https://openalex.org/I177725633"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5035368566"],"corresponding_institution_ids":["https://openalex.org/I177725633"],"apc_list":null,"apc_paid":null,"fwci":0.196,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.5172063,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1316","last_page":"1321"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11378","display_name":"Gastrointestinal Bleeding Diagnosis and Treatment","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2715","display_name":"Gastroenterology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11569","display_name":"Optical Coherence Tomography Applications","score":0.9909999966621399,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/optical-coherence-tomography","display_name":"Optical coherence tomography","score":0.8343397974967957},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7096821069717407},{"id":"https://openalex.org/keywords/rotation","display_name":"Rotation (mathematics)","score":0.5596745610237122},{"id":"https://openalex.org/keywords/coherence","display_name":"Coherence (philosophical gambling strategy)","score":0.5465696454048157},{"id":"https://openalex.org/keywords/optical-tomography","display_name":"Optical tomography","score":0.44597673416137695},{"id":"https://openalex.org/keywords/tomography","display_name":"Tomography","score":0.4112517237663269},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.39457884430885315},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.34942370653152466},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.3204615116119385},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.25642937421798706},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1958620846271515}],"concepts":[{"id":"https://openalex.org/C2778818243","wikidata":"https://www.wikidata.org/wiki/Q899552","display_name":"Optical coherence tomography","level":2,"score":0.8343397974967957},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7096821069717407},{"id":"https://openalex.org/C74050887","wikidata":"https://www.wikidata.org/wiki/Q848368","display_name":"Rotation (mathematics)","level":2,"score":0.5596745610237122},{"id":"https://openalex.org/C2781181686","wikidata":"https://www.wikidata.org/wiki/Q4226068","display_name":"Coherence (philosophical gambling strategy)","level":2,"score":0.5465696454048157},{"id":"https://openalex.org/C2777413408","wikidata":"https://www.wikidata.org/wiki/Q1968843","display_name":"Optical tomography","level":3,"score":0.44597673416137695},{"id":"https://openalex.org/C163716698","wikidata":"https://www.wikidata.org/wiki/Q841267","display_name":"Tomography","level":2,"score":0.4112517237663269},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.39457884430885315},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.34942370653152466},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3204615116119385},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.25642937421798706},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1958620846271515},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iros58592.2024.10802388","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iros58592.2024.10802388","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7900000214576721,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320307285","display_name":"Impact Fund","ror":"https://ror.org/00jb20j87"},{"id":"https://openalex.org/F4320326427","display_name":"Innovation and Technology Fund","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W219929715","https://openalex.org/W1956305767","https://openalex.org/W2022989186","https://openalex.org/W2036163000","https://openalex.org/W2106755569","https://openalex.org/W2128211516","https://openalex.org/W2134085852","https://openalex.org/W2139293048","https://openalex.org/W2228770073","https://openalex.org/W2325496248","https://openalex.org/W2495605196","https://openalex.org/W2599059164","https://openalex.org/W2604963436","https://openalex.org/W2767378450","https://openalex.org/W3015734988","https://openalex.org/W3108294908","https://openalex.org/W3194369447","https://openalex.org/W3215303412","https://openalex.org/W4283826389","https://openalex.org/W4312234176","https://openalex.org/W4382407534","https://openalex.org/W4390511324","https://openalex.org/W4392755083","https://openalex.org/W4392755470","https://openalex.org/W4401944565","https://openalex.org/W4402170799"],"related_works":["https://openalex.org/W2166934110","https://openalex.org/W2028558083","https://openalex.org/W3200823469","https://openalex.org/W2802586102","https://openalex.org/W2066831819","https://openalex.org/W2083453785","https://openalex.org/W2970707651","https://openalex.org/W2001904169","https://openalex.org/W2060139265","https://openalex.org/W2089574289"],"abstract_inverted_index":{"Miniature":[0],"rotation":[1,29,36,62,94,123,174,194],"actuators":[2,30,37],"have":[3,38],"been":[4,39],"extensively":[5],"developed":[6],"and":[7,21,68,111],"utilized":[8],"in":[9,19,41,53,71,166,179],"optical":[10],"coherence":[11],"tomography":[12],"(OCT)":[13],"endoscopy,":[14,43],"enabling":[15,87],"distortion-free":[16],"OCT":[17,42,75,152,170,186],"imaging":[18,73,153,190],"complex":[20],"tortuous":[22],"environments.":[23],"However,":[24],"the":[25,66,80,100,141,155,160,163],"use":[26,45],"of":[27,79,125,154,162],"electrical-driven":[28],"raises":[31],"safety":[32],"concerns.":[33],"Although":[34],"magnetic-driven":[35],"reported":[40],"their":[44],"can":[46,129],"potentially":[47],"interfere":[48],"with":[49,107,115],"other":[50],"medical":[51],"devices":[52],"clinical":[54],"settings.":[55],"Here,":[56],"we":[57,158],"propose":[58],"a":[59,85,104,112,116],"pneumatic":[60,127,164,173],"miniature":[61],"actuator":[63,81,128,165,175],"that":[64,191],"eliminates":[65],"electricity":[67],"magnetism":[69],"concerns":[70],"circumferential":[72],"for":[74],"endoscopy.":[76,171],"The":[77,122],"rotor":[78],"is":[82],"designed":[83],"as":[84],"windmill,":[86],"it":[88],"to":[89,98,134,146],"convert":[90],"air":[91],"energy":[92],"into":[93],"energy.":[95],"In":[96],"addition,":[97],"maintain":[99],"stable":[101],"rotation,":[102],"both":[103],"sliding":[105],"bearing":[106],"two":[108],"supporting":[109],"points":[110],"glass":[113],"spindle":[114],"half-ball":[117],"end":[118],"surface":[119],"are":[120],"developed.":[121],"speed":[124],"our":[126],"be":[130],"controlled":[131],"from":[132,144],"66":[133],"97":[135],"revolutions":[136],"per":[137,149],"second":[138],"by":[139],"adjusting":[140],"airflow":[142],"rate":[143],"3.25":[145],"4.00":[147],"liters":[148],"minute.":[150],"By":[151],"human":[156],"fingers,":[157],"demonstrate":[159],"feasibility":[161],"electricity-free":[167],"distal":[168],"scanning":[169],"Our":[172],"has":[176],"wide-ranging":[177],"potential":[178],"various":[180],"fiber-imaging":[181],"modalities,":[182],"including":[183],"not":[184],"only":[185],"but":[187],"also":[188],"ultrasound":[189],"requires":[192],"similar":[193],"capabilities.":[195]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-12-27T23:08:20.325037","created_date":"2025-10-10T00:00:00"}
