{"id":"https://openalex.org/W2212285614","doi":"https://doi.org/10.1109/iros.2015.7354081","title":"Development and evaluation of an MRI compatible finger rehabilitation device for stroke patients","display_name":"Development and evaluation of an MRI compatible finger rehabilitation device for stroke patients","publication_year":2015,"publication_date":"2015-09-01","ids":{"openalex":"https://openalex.org/W2212285614","doi":"https://doi.org/10.1109/iros.2015.7354081","mag":"2212285614"},"language":"en","primary_location":{"id":"doi:10.1109/iros.2015.7354081","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iros.2015.7354081","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081227900","display_name":"Zhenjin Tang","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Zhenjin Tang","raw_affiliation_strings":["Department of Modern Mechanical Engineering, Green Computing Systems Research Organization Center (Room 603), Shinjuku-Ku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Department of Modern Mechanical Engineering, Green Computing Systems Research Organization Center (Room 603), Shinjuku-Ku, Tokyo, Japan","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080654277","display_name":"Shigeki Sugano","orcid":"https://orcid.org/0000-0002-9331-2446"},"institutions":[{"id":"https://openalex.org/I150744194","display_name":"Waseda University","ror":"https://ror.org/00ntfnx83","country_code":"JP","type":"education","lineage":["https://openalex.org/I150744194"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Shigeki Sugano","raw_affiliation_strings":["S. Sugano is with the Department of Modern Mechanical Engineering, Waseda University, Shinjuku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"S. Sugano is with the Department of Modern Mechanical Engineering, Waseda University, Shinjuku, Tokyo, Japan","institution_ids":["https://openalex.org/I150744194"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101028615","display_name":"Hiroyasu Iwata","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hiroyasu Iwata","raw_affiliation_strings":["Department of Modern Mechanical Engineering, Green Computing Systems Research Organization Center (Room 603), Shinjuku-Ku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Department of Modern Mechanical Engineering, Green Computing Systems Research Organization Center (Room 603), Shinjuku-Ku, Tokyo, Japan","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5081227900"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5789,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.71617044,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"173","issue":null,"first_page":"5005","last_page":"5010"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10510","display_name":"Stroke Rehabilitation and Recovery","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2742","display_name":"Rehabilitation"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10510","display_name":"Stroke Rehabilitation and Recovery","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2742","display_name":"Rehabilitation"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scanner","display_name":"Scanner","score":0.7932349443435669},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7305570840835571},{"id":"https://openalex.org/keywords/ultrasonic-motor","display_name":"Ultrasonic motor","score":0.6742773652076721},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.6708056330680847},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6136834025382996},{"id":"https://openalex.org/keywords/robot","display_name":"Robot","score":0.5922279357910156},{"id":"https://openalex.org/keywords/rehabilitation","display_name":"Rehabilitation","score":0.5481935739517212},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.4544854164123535},{"id":"https://openalex.org/keywords/compatibility","display_name":"Compatibility (geochemistry)","score":0.4481045603752136},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.3917147219181061},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.31600967049598694},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2356504499912262},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1884460151195526},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.12277626991271973},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08228716254234314}],"concepts":[{"id":"https://openalex.org/C2779751349","wikidata":"https://www.wikidata.org/wiki/Q1474480","display_name":"Scanner","level":2,"score":0.7932349443435669},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7305570840835571},{"id":"https://openalex.org/C138794181","wikidata":"https://www.wikidata.org/wiki/Q10541502","display_name":"Ultrasonic motor","level":3,"score":0.6742773652076721},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.6708056330680847},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6136834025382996},{"id":"https://openalex.org/C90509273","wikidata":"https://www.wikidata.org/wiki/Q11012","display_name":"Robot","level":2,"score":0.5922279357910156},{"id":"https://openalex.org/C2778818304","wikidata":"https://www.wikidata.org/wiki/Q1819478","display_name":"Rehabilitation","level":2,"score":0.5481935739517212},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4544854164123535},{"id":"https://openalex.org/C2778648169","wikidata":"https://www.wikidata.org/wiki/Q967768","display_name":"Compatibility (geochemistry)","level":2,"score":0.4481045603752136},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3917147219181061},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.31600967049598694},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2356504499912262},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1884460151195526},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.12277626991271973},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08228716254234314},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.0},{"id":"https://openalex.org/C42360764","wikidata":"https://www.wikidata.org/wiki/Q83588","display_name":"Chemical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C1862650","wikidata":"https://www.wikidata.org/wiki/Q186005","display_name":"Physical therapy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iros.2015.7354081","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iros.2015.7354081","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","score":0.7699999809265137,"display_name":"Peace, Justice and strong institutions"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1506744885","https://openalex.org/W1964318214","https://openalex.org/W1987938015","https://openalex.org/W2002850293","https://openalex.org/W2010517011","https://openalex.org/W2035246484","https://openalex.org/W2076195568","https://openalex.org/W2080487795","https://openalex.org/W2093827521","https://openalex.org/W2113133147","https://openalex.org/W2119391912","https://openalex.org/W2149998541","https://openalex.org/W2153406438","https://openalex.org/W2171661311","https://openalex.org/W6992852660"],"related_works":["https://openalex.org/W2006140691","https://openalex.org/W4321512240","https://openalex.org/W88316594","https://openalex.org/W4229012123","https://openalex.org/W2367649163","https://openalex.org/W2945394195","https://openalex.org/W2027098359","https://openalex.org/W2119755427","https://openalex.org/W1597166842","https://openalex.org/W2070299453"],"abstract_inverted_index":{"This":[0,26],"paper":[1],"presents":[2],"the":[3,42,55,76,91,95,105,108,111,123,133,137,147],"design,":[4],"development":[5],"and":[6,18,34,54,63],"magnetic":[7],"resonance":[8],"imagining":[9],"(MRI)":[10],"compatibility":[11,74],"evaluation":[12],"of":[13,69,75,107,136],"a":[14,36,126],"small":[15],"size,":[16],"compact":[17],"adjustable":[19],"different":[20],"finger":[21,59,135],"phalange":[22],"lengths":[23],"rehabilitation":[24,144],"device.":[25],"device":[27],"employs":[28],"ultrasonic":[29],"motor":[30],"as":[31],"its":[32],"actuator":[33],"adopts":[35],"novel":[37],"six-link":[38],"mechanism":[39],"to":[40,48,60,141],"drive":[41],"finger.":[43],"The":[44,72,81],"final":[45],"system":[46],"enables":[47],"provide":[49],"two":[50],"joints":[51],"(the":[52],"MCP":[53],"PIP)":[56],"in":[57,110],"each":[58],"do":[61],"flexion":[62],"extension":[64],"motion":[65,145],"with":[66,118],"one":[67],"degree":[68],"freedom":[70],"(DOF).":[71],"MRI":[73,92,102,112,148],"robot":[77,96,109],"was":[78,120,130,139],"also":[79],"evaluated.":[80],"results":[82],"demonstrate":[83],"that":[84],"there":[85],"is":[86],"neither":[87],"an":[88,115],"effect":[89],"from":[90],"environment":[93],"on":[94,101],"performance,":[97],"nor":[98],"significant":[99],"degradation":[100],"images":[103],"by":[104],"introduction":[106],"scanner.":[113,149],"Finally,":[114],"fMRI":[116],"study":[117],"subject":[119,138],"carried":[121],"out,":[122],"result":[124],"shows":[125],"stable":[127],"brain":[128],"activation":[129],"observed":[131],"when":[132],"middle":[134],"driven":[140],"implement":[142],"passive":[143],"inside":[146]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
