{"id":"https://openalex.org/W2759696718","doi":"https://doi.org/10.1109/iolts.2017.8046245","title":"Temporal redundancy latch-based architecture for soft error mitigation","display_name":"Temporal redundancy latch-based architecture for soft error mitigation","publication_year":2017,"publication_date":"2017-07-01","ids":{"openalex":"https://openalex.org/W2759696718","doi":"https://doi.org/10.1109/iolts.2017.8046245","mag":"2759696718"},"language":"en","primary_location":{"id":"doi:10.1109/iolts.2017.8046245","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iolts.2017.8046245","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 23rd International Symposium on On-Line Testing and Robust System Design (IOLTS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5027952122","display_name":"Robert Schmidt","orcid":"https://orcid.org/0000-0002-1342-6292"},"institutions":[{"id":"https://openalex.org/I2898391981","display_name":"Deutsches Zentrum f\u00fcr Luft- und Raumfahrt e. V. (DLR)","ror":"https://ror.org/04bwf3e34","country_code":"DE","type":"facility","lineage":["https://openalex.org/I1305996414","https://openalex.org/I2898391981"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Robert Schmidt","raw_affiliation_strings":["Institute of Space Systems, German Aerospace Center, Bremen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Space Systems, German Aerospace Center, Bremen, Germany","institution_ids":["https://openalex.org/I2898391981"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050344559","display_name":"Alberto Garc\u00eda-Ortiz","orcid":"https://orcid.org/0000-0002-6461-3864"},"institutions":[{"id":"https://openalex.org/I180437899","display_name":"University of Bremen","ror":"https://ror.org/04ers2y35","country_code":"DE","type":"education","lineage":["https://openalex.org/I180437899"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Alberto Garcia-Ortiz","raw_affiliation_strings":["University of Bremen, Bremen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Bremen, Bremen, Germany","institution_ids":["https://openalex.org/I180437899"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008766097","display_name":"G\u00f6rschwin Fey","orcid":"https://orcid.org/0000-0001-6433-6265"},"institutions":[{"id":"https://openalex.org/I180437899","display_name":"University of Bremen","ror":"https://ror.org/04ers2y35","country_code":"DE","type":"education","lineage":["https://openalex.org/I180437899"]},{"id":"https://openalex.org/I2898391981","display_name":"Deutsches Zentrum f\u00fcr Luft- und Raumfahrt e. V. (DLR)","ror":"https://ror.org/04bwf3e34","country_code":"DE","type":"facility","lineage":["https://openalex.org/I1305996414","https://openalex.org/I2898391981"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Goerschwin Fey","raw_affiliation_strings":["Institute of Space Systems, German Aerospace Center, Bremen, Germany","University of Bremen, Bremen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Space Systems, German Aerospace Center, Bremen, Germany","institution_ids":["https://openalex.org/I2898391981"]},{"raw_affiliation_string":"University of Bremen, Bremen, Germany","institution_ids":["https://openalex.org/I180437899"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.5168,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.80173576,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"240","last_page":"243"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11032","display_name":"VLSI and Analog Circuit Testing","score":0.9829999804496765,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9815999865531921,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/triple-modular-redundancy","display_name":"Triple modular redundancy","score":0.9174578189849854},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.8877927660942078},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.6626694202423096},{"id":"https://openalex.org/keywords/soft-error","display_name":"Soft error","score":0.6576451063156128},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6126342415809631},{"id":"https://openalex.org/keywords/aerospace","display_name":"Aerospace","score":0.5751161575317383},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.5502618551254272},{"id":"https://openalex.org/keywords/digital-electronics","display_name":"Digital electronics","score":0.5014159679412842},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.464920312166214},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.45150646567344666},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.40889182686805725},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.34176206588745117},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27571040391921997},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.24525374174118042}],"concepts":[{"id":"https://openalex.org/C196371267","wikidata":"https://www.wikidata.org/wiki/Q3998979","display_name":"Triple modular redundancy","level":3,"score":0.9174578189849854},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.8877927660942078},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.6626694202423096},{"id":"https://openalex.org/C154474529","wikidata":"https://www.wikidata.org/wiki/Q1658917","display_name":"Soft error","level":2,"score":0.6576451063156128},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6126342415809631},{"id":"https://openalex.org/C167740415","wikidata":"https://www.wikidata.org/wiki/Q2876213","display_name":"Aerospace","level":2,"score":0.5751161575317383},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.5502618551254272},{"id":"https://openalex.org/C81843906","wikidata":"https://www.wikidata.org/wiki/Q173156","display_name":"Digital electronics","level":3,"score":0.5014159679412842},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.464920312166214},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.45150646567344666},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.40889182686805725},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.34176206588745117},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27571040391921997},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.24525374174118042},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iolts.2017.8046245","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iolts.2017.8046245","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 23rd International Symposium on On-Line Testing and Robust System Design (IOLTS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1541483005","https://openalex.org/W2025340565","https://openalex.org/W2071289751","https://openalex.org/W2095351656","https://openalex.org/W2147504603","https://openalex.org/W2152713935","https://openalex.org/W2156667996","https://openalex.org/W2160451204","https://openalex.org/W2164116828","https://openalex.org/W2178304595","https://openalex.org/W2306582323","https://openalex.org/W2473975584"],"related_works":["https://openalex.org/W58658798","https://openalex.org/W3114375939","https://openalex.org/W2797678940","https://openalex.org/W2759696718","https://openalex.org/W2359816675","https://openalex.org/W2995137536","https://openalex.org/W1749592617","https://openalex.org/W2491217195","https://openalex.org/W4210531477","https://openalex.org/W2537369590"],"abstract_inverted_index":{"Current":[0],"transients":[1,19],"caused":[2],"by":[3],"energetic":[4],"particle":[5],"strikes":[6],"are":[7],"a":[8,73],"serious":[9],"threat":[10],"for":[11],"digital":[12],"circuits":[13,36,50],"in":[14],"aerospace":[15,49],"applications.":[16],"Such":[17],"single-event":[18],"(SETs)":[20],"can":[21],"corrupt":[22],"the":[23,41],"circuit":[24,93],"state,":[25],"with":[26,37,81],"possibly":[27],"devastating":[28],"consequences.":[29],"Although":[30],"it":[31],"is":[32,46,72],"possible":[33],"to":[34,96],"protect":[35],"spatial":[38],"redundancy":[39,56,68,79,99],"techniques,":[40],"area":[42,82],"and":[43,90],"power":[44,86],"overhead":[45],"high.":[47],"Therefore":[48],"would":[51],"benefit":[52],"from":[53],"adopting":[54],"temporal":[55,67,78],"instead,":[57],"but":[58],"existing":[59],"solutions":[60],"prioritize":[61],"performance":[62],"over":[63],"reliability.":[64],"Our":[65],"proposed":[66],"latch-based":[69],"architecture":[70],"(TRLA)":[71],"standard":[74],"cell,":[75],"static":[76],"CMOS":[77],"technique,":[80],"savings":[83,87],"of":[84,88],"26%,":[85],"46%,":[89],"14%":[91],"faster":[92],"operation":[94],"compared":[95],"triple":[97],"modular":[98],"(TMR).":[100]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
