{"id":"https://openalex.org/W1997082362","doi":"https://doi.org/10.1109/iolts.2012.6313833","title":"SETTOFF: A fault tolerant flip-flop for building Cost-efficient Reliable Systems","display_name":"SETTOFF: A fault tolerant flip-flop for building Cost-efficient Reliable Systems","publication_year":2012,"publication_date":"2012-06-01","ids":{"openalex":"https://openalex.org/W1997082362","doi":"https://doi.org/10.1109/iolts.2012.6313833","mag":"1997082362"},"language":"en","primary_location":{"id":"doi:10.1109/iolts.2012.6313833","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iolts.2012.6313833","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE 18th International On-Line Testing Symposium (IOLTS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5063723352","display_name":"Lin Yang","orcid":"https://orcid.org/0000-0002-6910-2596"},"institutions":[{"id":"https://openalex.org/I43439940","display_name":"University of Southampton","ror":"https://ror.org/01ryk1543","country_code":"GB","type":"education","lineage":["https://openalex.org/I43439940"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Yang Lin","raw_affiliation_strings":["Electronics and Computer Science, University of Southampton, Southampton, UK","Electronics and Computer Science, University of Southampton, SO17 1BJ, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronics and Computer Science, University of Southampton, Southampton, UK","institution_ids":["https://openalex.org/I43439940"]},{"raw_affiliation_string":"Electronics and Computer Science, University of Southampton, SO17 1BJ, UK","institution_ids":["https://openalex.org/I43439940"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077466475","display_name":"Mark Zwoli\u0144ski","orcid":"https://orcid.org/0000-0002-2230-625X"},"institutions":[{"id":"https://openalex.org/I43439940","display_name":"University of Southampton","ror":"https://ror.org/01ryk1543","country_code":"GB","type":"education","lineage":["https://openalex.org/I43439940"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Mark Zwolinski","raw_affiliation_strings":["Electronics and Computer Science, University of Southampton, Southampton, UK","Electronics and Computer Science, University of Southampton, SO17 1BJ, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronics and Computer Science, University of Southampton, Southampton, UK","institution_ids":["https://openalex.org/I43439940"]},{"raw_affiliation_string":"Electronics and Computer Science, University of Southampton, SO17 1BJ, UK","institution_ids":["https://openalex.org/I43439940"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I43439940"],"apc_list":null,"apc_paid":null,"fwci":2.0616,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.85578754,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"7","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10502","display_name":"Advanced Memory and Neural Computing","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.8206556439399719},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.7933075428009033},{"id":"https://openalex.org/keywords/flip-flop","display_name":"Flip-flop","score":0.7552019357681274},{"id":"https://openalex.org/keywords/soft-error","display_name":"Soft error","score":0.6655871868133545},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6305940747261047},{"id":"https://openalex.org/keywords/overhead","display_name":"Overhead (engineering)","score":0.5520230531692505},{"id":"https://openalex.org/keywords/architecture","display_name":"Architecture","score":0.5181004405021667},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4933878481388092},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.45678624510765076},{"id":"https://openalex.org/keywords/fault-coverage","display_name":"Fault coverage","score":0.4454461336135864},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.41666799783706665},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3834395110607147},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2383006513118744},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.23071321845054626},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.20354700088500977},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.1757284700870514},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11079055070877075},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.08933702111244202},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.08763954043388367}],"concepts":[{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.8206556439399719},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.7933075428009033},{"id":"https://openalex.org/C2781007278","wikidata":"https://www.wikidata.org/wiki/Q183406","display_name":"Flip-flop","level":3,"score":0.7552019357681274},{"id":"https://openalex.org/C154474529","wikidata":"https://www.wikidata.org/wiki/Q1658917","display_name":"Soft error","level":2,"score":0.6655871868133545},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6305940747261047},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.5520230531692505},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.5181004405021667},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4933878481388092},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.45678624510765076},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.4454461336135864},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.41666799783706665},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3834395110607147},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2383006513118744},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.23071321845054626},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.20354700088500977},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.1757284700870514},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11079055070877075},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.08933702111244202},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.08763954043388367},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C153349607","wikidata":"https://www.wikidata.org/wiki/Q36649","display_name":"Visual arts","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C162307627","wikidata":"https://www.wikidata.org/wiki/Q204833","display_name":"Enhanced Data Rates for GSM Evolution","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iolts.2012.6313833","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iolts.2012.6313833","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE 18th International On-Line Testing Symposium (IOLTS)","raw_type":"proceedings-article"},{"id":"pmh:oai:eprints.soton.ac.uk:341995","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4306401019","display_name":"ePrints Soton (University of Southampton)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I43439940","host_organization_name":"University of Southampton","host_organization_lineage":["https://openalex.org/I43439940"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Conference or Workshop Item"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11","score":0.49000000953674316}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1541483005","https://openalex.org/W1980433502","https://openalex.org/W2013185880","https://openalex.org/W2023856022","https://openalex.org/W2025474944","https://openalex.org/W2036359829","https://openalex.org/W2085559938","https://openalex.org/W2104677471","https://openalex.org/W2109808009","https://openalex.org/W2120444887","https://openalex.org/W2121865804","https://openalex.org/W2125424208","https://openalex.org/W2142557656","https://openalex.org/W2148327955","https://openalex.org/W2152897606","https://openalex.org/W2178304595","https://openalex.org/W4229966209","https://openalex.org/W4236432903","https://openalex.org/W6632410504"],"related_works":["https://openalex.org/W2108400598","https://openalex.org/W2025041939","https://openalex.org/W2153096481","https://openalex.org/W2148616436","https://openalex.org/W2102525122","https://openalex.org/W4221123967","https://openalex.org/W4245282135","https://openalex.org/W2047736125","https://openalex.org/W4306316843","https://openalex.org/W2130594209"],"abstract_inverted_index":{"Conventional":[0],"fault":[1,16,112],"tolerance":[2,113],"techniques":[3],"either":[4],"require":[5],"big":[6],"overheads":[7],"or":[8],"have":[9],"limited":[10],"reliability.":[11],"We":[12],"propose":[13],"a":[14,46,65,70,82],"novel":[15],"tolerant":[17],"flip-flop":[18,47,84,103],"(SETTOFF)":[19],"that":[20],"addresses":[21],"timing":[22,56],"errors":[23,26,57],"and":[24,48,58,77,87],"soft":[25],"in":[27,85,118],"one":[28],"cost-efficient":[29],"architecture.":[30,68],"In":[31],"SETTOFF,":[32],"most":[33],"SEUs":[34,61],"are":[35,62],"detected":[36,63],"by":[37,50,64],"monitoring":[38],"the":[39,43,52,59,99,133],"illegal":[40],"transitions":[41],"at":[42,129],"output":[44],"of":[45,111],"recovered":[49],"inverting":[51],"cell":[53],"state.":[54],"SETs,":[55],"other":[60],"time":[66],"redundancy-based":[67],"For":[69],"10%":[71],"activity":[72],"rate,":[73],"SETTOFF":[74,105],"consumes":[75,93],"35.8%":[76],"39.7%":[78],"more":[79,96],"power":[80,97],"than":[81,98,132],"library":[83],"120nm":[86],"65nm":[88],"technologies,":[89],"respectively.":[90],"It":[91],"only":[92,115],"about":[94],"5.7%":[95],"detection":[100],"based":[101],"RazorII":[102],"[1].":[104],"therefore":[106],"provides":[107],"an":[108],"increased":[109],"coverage":[110],"with":[114],"moderate":[116],"increase":[117],"overhead,":[119],"hence":[120],"it":[121],"is":[122],"suitable":[123],"for":[124],"building":[125],"highly":[126],"reliable":[127],"systems":[128],"lower":[130],"cost":[131],"traditional":[134],"techniques.":[135]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
