{"id":"https://openalex.org/W7118392342","doi":"https://doi.org/10.1109/indin64977.2025.11279498","title":"Air Quality Sensors for Energy-saving and Self-diagnostics of a Local Exhaust Ventilation System with Self-powered Airflow Controller","display_name":"Air Quality Sensors for Energy-saving and Self-diagnostics of a Local Exhaust Ventilation System with Self-powered Airflow Controller","publication_year":2025,"publication_date":"2025-07-12","ids":{"openalex":"https://openalex.org/W7118392342","doi":"https://doi.org/10.1109/indin64977.2025.11279498"},"language":null,"primary_location":{"id":"doi:10.1109/indin64977.2025.11279498","is_oa":false,"landing_page_url":"https://doi.org/10.1109/indin64977.2025.11279498","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 23rd International Conference on Industrial Informatics (INDIN)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014343218","display_name":"Zheng Jun Chew","orcid":"https://orcid.org/0000-0001-8455-0365"},"institutions":[{"id":"https://openalex.org/I23923803","display_name":"University of Exeter","ror":"https://ror.org/03yghzc09","country_code":"GB","type":"education","lineage":["https://openalex.org/I23923803"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Zheng Jun Chew","raw_affiliation_strings":["University of Exeter,Faculty of Environment, Science and Economy,Exeter,UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Exeter,Faculty of Environment, Science and Economy,Exeter,UK","institution_ids":["https://openalex.org/I23923803"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087609310","display_name":"Latifah Munirah Kamarudin","orcid":"https://orcid.org/0000-0002-2547-3934"},"institutions":[{"id":"https://openalex.org/I65079550","display_name":"Universiti Malaysia Perlis","ror":"https://ror.org/00xmkb790","country_code":"MY","type":"education","lineage":["https://openalex.org/I65079550"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Latifah Munirah Kamarudin","raw_affiliation_strings":["Universiti Malaysia Perlis,Center of Excellence for Advanced Sensor Technology,Perlis,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Malaysia Perlis,Center of Excellence for Advanced Sensor Technology,Perlis,Malaysia","institution_ids":["https://openalex.org/I65079550"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044465736","display_name":"Ammar Zakaria","orcid":"https://orcid.org/0000-0002-7108-215X"},"institutions":[{"id":"https://openalex.org/I65079550","display_name":"Universiti Malaysia Perlis","ror":"https://ror.org/00xmkb790","country_code":"MY","type":"education","lineage":["https://openalex.org/I65079550"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Ammar Zakaria","raw_affiliation_strings":["Universiti Malaysia Perlis,Center of Excellence for Advanced Sensor Technology,Perlis,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Malaysia Perlis,Center of Excellence for Advanced Sensor Technology,Perlis,Malaysia","institution_ids":["https://openalex.org/I65079550"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037308871","display_name":"Syed Muhammad Mamduh Syed Zakaria","orcid":"https://orcid.org/0000-0003-3557-2204"},"institutions":[{"id":"https://openalex.org/I65079550","display_name":"Universiti Malaysia Perlis","ror":"https://ror.org/00xmkb790","country_code":"MY","type":"education","lineage":["https://openalex.org/I65079550"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Syed Muhammad Mamduh Syed Zakaria","raw_affiliation_strings":["Universiti Malaysia Perlis,Center of Excellence for Advanced Sensor Technology,Perlis,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Malaysia Perlis,Center of Excellence for Advanced Sensor Technology,Perlis,Malaysia","institution_ids":["https://openalex.org/I65079550"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5122052422","display_name":"Balreddy Kothakapu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210090529","display_name":"Andover Eye Associates","ror":"https://ror.org/00gb2qm43","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I4210090529"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Balreddy Kothakapu","raw_affiliation_strings":["R&#x0026;B Industrial,Electrical Department,Andover,UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"R&#x0026;B Industrial,Electrical Department,Andover,UK","institution_ids":["https://openalex.org/I4210090529"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5122280924","display_name":"Roger Watson","orcid":null},"institutions":[{"id":"https://openalex.org/I4210161090","display_name":"China National Centre for Food Safety Risk Assessment","ror":"https://ror.org/058mseb02","country_code":"CN","type":"government","lineage":["https://openalex.org/I4210161090"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Roger Watson","raw_affiliation_strings":["R&#x0026;B Industrial,DSEAR Risk Assessment and Occupational Hygiene,Andover,UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"R&#x0026;B Industrial,DSEAR Risk Assessment and Occupational Hygiene,Andover,UK","institution_ids":["https://openalex.org/I4210161090"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083613815","display_name":"Clive Bates","orcid":"https://orcid.org/0000-0002-4106-7119"},"institutions":[{"id":"https://openalex.org/I4210090529","display_name":"Andover Eye Associates","ror":"https://ror.org/00gb2qm43","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I4210090529"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Clive Bates","raw_affiliation_strings":["R&#x0026;B Industrial,Electrical Department,Andover,UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"R&#x0026;B Industrial,Electrical Department,Andover,UK","institution_ids":["https://openalex.org/I4210090529"]}]}],"institutions":[],"countries_distinct_count":4,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.66904084,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12120","display_name":"Air Quality Monitoring and Forecasting","score":0.6976000070571899,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12120","display_name":"Air Quality Monitoring and Forecasting","score":0.6976000070571899,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10990","display_name":"Infection Control and Ventilation","score":0.029500000178813934,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12163","display_name":"Aerosol Filtration and Electrostatic Precipitation","score":0.01810000091791153,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/airflow","display_name":"Airflow","score":0.8432000279426575},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.5813999772071838},{"id":"https://openalex.org/keywords/air-quality-index","display_name":"Air quality index","score":0.5260999798774719},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5085999965667725},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.45809999108314514},{"id":"https://openalex.org/keywords/particulates","display_name":"Particulates","score":0.4544000029563904},{"id":"https://openalex.org/keywords/secondary-air-injection","display_name":"Secondary air injection","score":0.3668000102043152},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.3578999936580658}],"concepts":[{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.8432000279426575},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5947999954223633},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5813999772071838},{"id":"https://openalex.org/C126314574","wikidata":"https://www.wikidata.org/wiki/Q2364111","display_name":"Air quality index","level":2,"score":0.5260999798774719},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5085999965667725},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.45809999108314514},{"id":"https://openalex.org/C24245907","wikidata":"https://www.wikidata.org/wiki/Q498957","display_name":"Particulates","level":2,"score":0.4544000029563904},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4117000102996826},{"id":"https://openalex.org/C17623918","wikidata":"https://www.wikidata.org/wiki/Q441828","display_name":"Secondary air injection","level":2,"score":0.3668000102043152},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.3578999936580658},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.35740000009536743},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3522999882698059},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3499000072479248},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3059000074863434},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2980000078678131},{"id":"https://openalex.org/C559116025","wikidata":"https://www.wikidata.org/wiki/Q131123","display_name":"Air pollution","level":2,"score":0.28690001368522644},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.2799000144004822},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.2770000100135803},{"id":"https://openalex.org/C58581272","wikidata":"https://www.wikidata.org/wiki/Q12741163","display_name":"Workspace","level":3,"score":0.26980000734329224},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.26440000534057617},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.25529998540878296},{"id":"https://openalex.org/C17005505","wikidata":"https://www.wikidata.org/wiki/Q11164636","display_name":"Energy recovery ventilation","level":4,"score":0.25429999828338623}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/indin64977.2025.11279498","is_oa":false,"landing_page_url":"https://doi.org/10.1109/indin64977.2025.11279498","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 23rd International Conference on Industrial Informatics (INDIN)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8744637966156006,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320241","display_name":"Academy of Medical Sciences","ror":"https://ror.org/00c489v88"},{"id":"https://openalex.org/F4320320275","display_name":"University of Exeter","ror":"https://ror.org/03yghzc09"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1521009992","https://openalex.org/W2181439470","https://openalex.org/W2537357836","https://openalex.org/W2607398338","https://openalex.org/W2780406094","https://openalex.org/W2904359146","https://openalex.org/W2912696304","https://openalex.org/W3035928673","https://openalex.org/W3091771970","https://openalex.org/W3097236531","https://openalex.org/W3128566938","https://openalex.org/W4210263590","https://openalex.org/W4224280137","https://openalex.org/W4224942929","https://openalex.org/W4297200719","https://openalex.org/W4300773761","https://openalex.org/W4324387148","https://openalex.org/W4367031965","https://openalex.org/W4405304923","https://openalex.org/W4405305807"],"related_works":[],"abstract_inverted_index":{"Air":[0],"quality":[1],"(AQ)":[2],"is":[3,19,55],"crucial":[4],"in":[5,44],"the":[6,30,72,82,108,137,143],"industry":[7],"for":[8,85,99],"financial":[9],"as":[10,12,146,148],"well":[11,147],"health":[13,150],"and":[14,23,65,87,116,140,151],"safety":[15],"reasons.":[16],"Thus,":[17],"it":[18],"imperative":[20],"to":[21,61,80,94],"monitor":[22],"control":[24],"workspace":[25],"AQ.":[26],"This":[27,135],"paper":[28],"proposed":[29],"integration":[31],"of":[32,71,107,125,131,142],"a":[33,45,76,122,129,132],"smart":[34],"AQ":[35,52],"sensor":[36,53],"system":[37,54,145],"with":[38,57,103],"self-powered":[39],"autonomous":[40],"airflow":[41,68,97],"controllers":[42],"(AACs)":[43],"local":[46,77],"exhaust":[47],"ventilation":[48],"(LEV)":[49],"system.":[50,110,134],"The":[51,67],"integrated":[56],"artificial":[58],"intelligence":[59],"(AI)":[60],"improve":[62],"sensing":[63,86],"performance":[64],"reliability.":[66],"energy":[69,83,105],"harvester":[70],"AAC":[73],"could":[74,127],"provide":[75],"power":[78],"source":[79],"meet":[81],"demand":[84],"AI.":[88],"Sensor":[89],"readings":[90],"can":[91],"be":[92,128],"used":[93],"set":[95],"appropriate":[96],"velocities":[98],"effective":[100],"pollutant":[101],"removal":[102],"optimized":[104],"consumption":[106],"LEV":[109,144],"High":[111],"volatile":[112],"organic":[113],"compounds":[114],"(VOCs)":[115],"particulate":[117],"matter":[118],"(PM)":[119],"levels":[120],"after":[121],"long":[123],"period":[124],"operation":[126],"sign":[130],"faulty":[133],"improves":[136],"efficiency,":[138],"resilience,":[139],"reliability":[141],"worker":[149],"safety.":[152]},"counts_by_year":[],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2026-01-08T00:00:00"}
