{"id":"https://openalex.org/W3207109945","doi":"https://doi.org/10.1109/indin45523.2021.9557553","title":"Comparison of PMSMs Motor Current Signature Analysis and Motor Torque Analysis Under Transient Conditions","display_name":"Comparison of PMSMs Motor Current Signature Analysis and Motor Torque Analysis Under Transient Conditions","publication_year":2021,"publication_date":"2021-07-21","ids":{"openalex":"https://openalex.org/W3207109945","doi":"https://doi.org/10.1109/indin45523.2021.9557553","mag":"3207109945"},"language":"en","primary_location":{"id":"doi:10.1109/indin45523.2021.9557553","is_oa":false,"landing_page_url":"https://doi.org/10.1109/indin45523.2021.9557553","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE 19th International Conference on Industrial Informatics (INDIN)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034761885","display_name":"Andrea Bonci","orcid":"https://orcid.org/0000-0003-0265-1598"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Andrea Bonci","raw_affiliation_strings":["Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy"],"affiliations":[{"raw_affiliation_string":"Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy","institution_ids":["https://openalex.org/I122534668"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040901825","display_name":"Marina Indri","orcid":"https://orcid.org/0000-0002-2740-9514"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Marina Indri","raw_affiliation_strings":["Politecnico di Torino,Dept. of Electronics and Telecommunication,Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Dept. of Electronics and Telecommunication,Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073565131","display_name":"Renat Kermenov","orcid":"https://orcid.org/0000-0002-8985-9510"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Renat Kermenov","raw_affiliation_strings":["Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy"],"affiliations":[{"raw_affiliation_string":"Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy","institution_ids":["https://openalex.org/I122534668"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082166443","display_name":"Sauro Longhi","orcid":"https://orcid.org/0000-0002-1997-8098"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Sauro Longhi","raw_affiliation_strings":["Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy"],"affiliations":[{"raw_affiliation_string":"Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy","institution_ids":["https://openalex.org/I122534668"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082043642","display_name":"Giacomo Nabissi","orcid":"https://orcid.org/0000-0002-5386-1651"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Giacomo Nabissi","raw_affiliation_strings":["Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy"],"affiliations":[{"raw_affiliation_string":"Polytechnic University of Marche,Dept. of Information Engineering,Ancona,Italy","institution_ids":["https://openalex.org/I122534668"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5034761885"],"corresponding_institution_ids":["https://openalex.org/I122534668"],"apc_list":null,"apc_paid":null,"fwci":0.412,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.61698541,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9889000058174133,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9779999852180481,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.6404762268066406},{"id":"https://openalex.org/keywords/signature","display_name":"Signature (topology)","score":0.5870019793510437},{"id":"https://openalex.org/keywords/mechatronics","display_name":"Mechatronics","score":0.5674460530281067},{"id":"https://openalex.org/keywords/kalman-filter","display_name":"Kalman filter","score":0.564812421798706},{"id":"https://openalex.org/keywords/electric-motor","display_name":"Electric motor","score":0.5299611687660217},{"id":"https://openalex.org/keywords/extended-kalman-filter","display_name":"Extended Kalman filter","score":0.48802271485328674},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.48532456159591675},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.48236721754074097},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46966254711151123},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.4613499641418457},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4508582353591919},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.45053809881210327},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.43247249722480774},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.30334997177124023},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10596707463264465},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.09645572304725647},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09462898969650269},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.08151558041572571},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08039799332618713}],"concepts":[{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.6404762268066406},{"id":"https://openalex.org/C2779696439","wikidata":"https://www.wikidata.org/wiki/Q7512811","display_name":"Signature (topology)","level":2,"score":0.5870019793510437},{"id":"https://openalex.org/C28704281","wikidata":"https://www.wikidata.org/wiki/Q180165","display_name":"Mechatronics","level":2,"score":0.5674460530281067},{"id":"https://openalex.org/C157286648","wikidata":"https://www.wikidata.org/wiki/Q846780","display_name":"Kalman filter","level":2,"score":0.564812421798706},{"id":"https://openalex.org/C176871988","wikidata":"https://www.wikidata.org/wiki/Q72313","display_name":"Electric motor","level":2,"score":0.5299611687660217},{"id":"https://openalex.org/C206833254","wikidata":"https://www.wikidata.org/wiki/Q5421817","display_name":"Extended Kalman filter","level":3,"score":0.48802271485328674},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.48532456159591675},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.48236721754074097},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46966254711151123},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4613499641418457},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4508582353591919},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.45053809881210327},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.43247249722480774},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.30334997177124023},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10596707463264465},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09645572304725647},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09462898969650269},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.08151558041572571},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08039799332618713},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/indin45523.2021.9557553","is_oa":false,"landing_page_url":"https://doi.org/10.1109/indin45523.2021.9557553","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE 19th International Conference on Industrial Informatics (INDIN)","raw_type":"proceedings-article"},{"id":"pmh:oai:iris.univpm.it:11566/300789","is_oa":false,"landing_page_url":"https://ieeexplore.ieee.org/document/9557553","pdf_url":null,"source":{"id":"https://openalex.org/S4306402571","display_name":"Universit\u00e0 Politecnica delle Marche (Universit\u00e0 Politecnica delle Marche)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I122534668","host_organization_name":"Marche Polytechnic University","host_organization_lineage":["https://openalex.org/I122534668"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W125459439","https://openalex.org/W1965930833","https://openalex.org/W2003083486","https://openalex.org/W2021860225","https://openalex.org/W2051861458","https://openalex.org/W2089345764","https://openalex.org/W2098626917","https://openalex.org/W2103049017","https://openalex.org/W2120516841","https://openalex.org/W2132265582","https://openalex.org/W2139615563","https://openalex.org/W2528459294","https://openalex.org/W2754485079","https://openalex.org/W2980846788","https://openalex.org/W3035986198","https://openalex.org/W3129265343","https://openalex.org/W3133459165","https://openalex.org/W3163731913","https://openalex.org/W4254422234"],"related_works":["https://openalex.org/W2913189039","https://openalex.org/W613097443","https://openalex.org/W2888778368","https://openalex.org/W1889691171","https://openalex.org/W4236890452","https://openalex.org/W2484273923","https://openalex.org/W1991400806","https://openalex.org/W1717190054","https://openalex.org/W2075474585","https://openalex.org/W1613885380"],"abstract_inverted_index":{"PMSMs":[0],"are":[1,108],"widely":[2],"used":[3],"in":[4],"applications":[5],"on":[6,61],"electric":[7,69],"vehicles,":[8],"robotics":[9],"and":[10,46],"mechatronic":[11],"systems":[12],"of":[13,55,68,101,115],"industrial":[14],"machinery.":[15],"Thus":[16],"it":[17],"becomes":[18],"increasingly":[19],"interesting":[20],"to":[21],"prevent":[22],"their":[23,91],"fault":[24],"or":[25],"malfunctioning":[26],"with":[27,83],"Predictive":[28],"Maintenance":[29],"(PdM).":[30],"However,":[31],"reaching":[32],"this":[33],"outcome":[34],"could":[35],"be":[36],"difficult,":[37],"especially":[38],"if":[39],"the":[40,53,66,84,95,99,111,116],"stationary":[41],"condition":[42],"is":[43,81],"not":[44],"achieved":[45],"without":[47],"additional":[48],"sensors.":[49],"This":[50],"paper":[51],"examines":[52],"use":[54],"a":[56],"load":[57],"torque":[58],"observer":[59],"based":[60],"Extended":[62],"Kalman":[63],"Filter":[64],"for":[65],"diagnosis":[67],"drives":[70],"working":[71],"under":[72,94,105,118],"non-stationary":[73,106],"conditions.":[74,97,120],"The":[75],"proposed":[76],"Motor":[77,85],"Torque":[78],"Analysis":[79,88],"(MTA)":[80],"compared":[82],"Current":[86],"Signature":[87],"by":[89],"evaluating":[90],"diagnostic":[92,113],"capabilities":[93,114],"assumed":[96],"Finally,":[98],"results":[100],"bearing":[102],"failure":[103],"detection":[104],"conditions":[107],"presented,":[109],"highlighting":[110],"superior":[112],"MTA":[117],"such":[119]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
