{"id":"https://openalex.org/W2285614574","doi":"https://doi.org/10.1109/igcc.2015.7393715","title":"Dynamic workload and cooling management in high-efficiency data centers","display_name":"Dynamic workload and cooling management in high-efficiency data centers","publication_year":2015,"publication_date":"2015-12-01","ids":{"openalex":"https://openalex.org/W2285614574","doi":"https://doi.org/10.1109/igcc.2015.7393715","mag":"2285614574"},"language":"en","primary_location":{"id":"doi:10.1109/igcc.2015.7393715","is_oa":false,"landing_page_url":"https://doi.org/10.1109/igcc.2015.7393715","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 Sixth International Green and Sustainable Computing Conference (IGSC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://oa.upm.es/42750/","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050801793","display_name":"Marina Zapater","orcid":"https://orcid.org/0000-0002-6971-1965"},"institutions":[{"id":"https://openalex.org/I121748325","display_name":"Universidad Complutense de Madrid","ror":"https://ror.org/02p0gd045","country_code":"ES","type":"education","lineage":["https://openalex.org/I121748325"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Marina Zapater","raw_affiliation_strings":["DACYA Universidad Complutense de Madrid, Madrid, Spain"],"affiliations":[{"raw_affiliation_string":"DACYA Universidad Complutense de Madrid, Madrid, Spain","institution_ids":["https://openalex.org/I121748325"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108270551","display_name":"Ata T\u00fcrk","orcid":null},"institutions":[{"id":"https://openalex.org/I111088046","display_name":"Boston University","ror":"https://ror.org/05qwgg493","country_code":"US","type":"education","lineage":["https://openalex.org/I111088046"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ata Turk","raw_affiliation_strings":["ECE Department, Boston University, Boston, MA"],"affiliations":[{"raw_affiliation_string":"ECE Department, Boston University, Boston, MA","institution_ids":["https://openalex.org/I111088046"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108005137","display_name":"Jos\u00e9 M. Moya","orcid":"https://orcid.org/0000-0001-7926-9384"},"institutions":[{"id":"https://openalex.org/I88060688","display_name":"Universidad Polit\u00e9cnica de Madrid","ror":"https://ror.org/03n6nwv02","country_code":"ES","type":"education","lineage":["https://openalex.org/I88060688"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jose M. Moya","raw_affiliation_strings":["Laboratorio de Sistemas Intearados (LSI), Universidad Polit\u00e9cnica de Madrid, Madrid, Spain"],"affiliations":[{"raw_affiliation_string":"Laboratorio de Sistemas Intearados (LSI), Universidad Polit\u00e9cnica de Madrid, Madrid, Spain","institution_ids":["https://openalex.org/I88060688"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067064660","display_name":"Jos\u00e9 L. Ayala","orcid":"https://orcid.org/0000-0001-7236-5330"},"institutions":[{"id":"https://openalex.org/I121748325","display_name":"Universidad Complutense de Madrid","ror":"https://ror.org/02p0gd045","country_code":"ES","type":"education","lineage":["https://openalex.org/I121748325"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jose L. Ayala","raw_affiliation_strings":["DACYA Universidad Complutense de Madrid, Madrid, Spain"],"affiliations":[{"raw_affiliation_string":"DACYA Universidad Complutense de Madrid, Madrid, Spain","institution_ids":["https://openalex.org/I121748325"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5064676631","display_name":"Ayse K. Coskun","orcid":"https://orcid.org/0000-0002-6554-088X"},"institutions":[{"id":"https://openalex.org/I111088046","display_name":"Boston University","ror":"https://ror.org/05qwgg493","country_code":"US","type":"education","lineage":["https://openalex.org/I111088046"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ayse K. Coskun","raw_affiliation_strings":["ECE Department, Boston University, Boston, MA"],"affiliations":[{"raw_affiliation_string":"ECE Department, Boston University, Boston, MA","institution_ids":["https://openalex.org/I111088046"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5050801793"],"corresponding_institution_ids":["https://openalex.org/I121748325"],"apc_list":null,"apc_paid":null,"fwci":3.2459,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.93277231,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.9171749353408813},{"id":"https://openalex.org/keywords/workload","display_name":"Workload","score":0.8519113063812256},{"id":"https://openalex.org/keywords/rack","display_name":"Rack","score":0.6999077796936035},{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.5793014168739319},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.559196949005127},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.548173725605011},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5387914776802063},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.49066436290740967},{"id":"https://openalex.org/keywords/power-management","display_name":"Power management","score":0.4756985604763031},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.4724840521812439},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4578065574169159},{"id":"https://openalex.org/keywords/air-cooling","display_name":"Air cooling","score":0.45263445377349854},{"id":"https://openalex.org/keywords/free-cooling","display_name":"Free cooling","score":0.45176416635513306},{"id":"https://openalex.org/keywords/water-cooling","display_name":"Water cooling","score":0.43623101711273193},{"id":"https://openalex.org/keywords/cooling-load","display_name":"Cooling load","score":0.43332821130752563},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3707122802734375},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.34950870275497437},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.28891634941101074},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21439188718795776},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.16780343651771545},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1456986665725708},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.09497499465942383}],"concepts":[{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.9171749353408813},{"id":"https://openalex.org/C2778476105","wikidata":"https://www.wikidata.org/wiki/Q628539","display_name":"Workload","level":2,"score":0.8519113063812256},{"id":"https://openalex.org/C2776843527","wikidata":"https://www.wikidata.org/wiki/Q1351382","display_name":"Rack","level":2,"score":0.6999077796936035},{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.5793014168739319},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.559196949005127},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.548173725605011},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5387914776802063},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.49066436290740967},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.4756985604763031},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4724840521812439},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4578065574169159},{"id":"https://openalex.org/C105873366","wikidata":"https://www.wikidata.org/wiki/Q1208873","display_name":"Air cooling","level":2,"score":0.45263445377349854},{"id":"https://openalex.org/C49996111","wikidata":"https://www.wikidata.org/wiki/Q2277783","display_name":"Free cooling","level":3,"score":0.45176416635513306},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.43623101711273193},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.43332821130752563},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3707122802734375},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34950870275497437},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.28891634941101074},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21439188718795776},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.16780343651771545},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1456986665725708},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.09497499465942383},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/igcc.2015.7393715","is_oa":false,"landing_page_url":"https://doi.org/10.1109/igcc.2015.7393715","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 Sixth International Green and Sustainable Computing Conference (IGSC)","raw_type":"proceedings-article"},{"id":"pmh:oai:hesso.tind.io:9117","is_oa":false,"landing_page_url":"https://arodes.hes-so.ch/record/9117/files/Published%20version.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S4306402432","display_name":"ArODES (HES-SO (https://www.hes-so.ch/))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210088449","host_organization_name":"HES-SO Gen\u00e8ve","host_organization_lineage":["https://openalex.org/I4210088449"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://arodes.hes-so.ch/record/9117","raw_type":"Text"},{"id":"pmh:oai:oa.upm.es:42750","is_oa":true,"landing_page_url":"http://oa.upm.es/42750/","pdf_url":null,"source":{"id":"https://openalex.org/S4377196323","display_name":"UPM Digital Archive (Technical University of Madrid)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I88060688","host_organization_name":"Universidad Polit\u00e9cnica de Madrid","host_organization_lineage":["https://openalex.org/I88060688"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sixth International Green Computing Conference and Sustainable Computing Conference (IGSC 2015) | Sixth International Green Computing Conference and Sustainable Computing Conference (IGSC 2015) | 14/12/2015 - 16/12/2015 | Las Vegas, NV, USA","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:oa.upm.es:42750","is_oa":true,"landing_page_url":"http://oa.upm.es/42750/","pdf_url":null,"source":{"id":"https://openalex.org/S4377196323","display_name":"UPM Digital Archive (Technical University of Madrid)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I88060688","host_organization_name":"Universidad Polit\u00e9cnica de Madrid","host_organization_lineage":["https://openalex.org/I88060688"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sixth International Green Computing Conference and Sustainable Computing Conference (IGSC 2015) | Sixth International Green Computing Conference and Sustainable Computing Conference (IGSC 2015) | 14/12/2015 - 16/12/2015 | Las Vegas, NV, USA","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8899999856948853,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320330412","display_name":"Scheme for Promotion of Academic and Research Collaboration","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W308112794","https://openalex.org/W1552934126","https://openalex.org/W1596936080","https://openalex.org/W1820266221","https://openalex.org/W1966928035","https://openalex.org/W2067549201","https://openalex.org/W2073938709","https://openalex.org/W2116571143","https://openalex.org/W2124942711","https://openalex.org/W2149212714","https://openalex.org/W2170002197","https://openalex.org/W2808980893","https://openalex.org/W3216259206","https://openalex.org/W6610821580","https://openalex.org/W6668793224","https://openalex.org/W6804443746"],"related_works":["https://openalex.org/W2368264945","https://openalex.org/W2377784227","https://openalex.org/W2285889907","https://openalex.org/W2502423323","https://openalex.org/W2034170042","https://openalex.org/W1541204212","https://openalex.org/W2936458299","https://openalex.org/W2068283697","https://openalex.org/W1915709946","https://openalex.org/W4384557780"],"abstract_inverted_index":{"Energy":[0],"efficiency":[1],"research":[2],"in":[3,51,75,116,134],"data":[4,40,90,94,118],"centers":[5,41],"has":[6],"traditionally":[7],"focused":[8],"on":[9],"raised-floor":[10],"air-cooled":[11],"facilities.":[12],"As":[13],"rack":[14],"power":[15,48,86,127],"density":[16],"increases,":[17],"traditional":[18],"cooling":[19,31,74,111],"is":[20,81],"being":[21],"replaced":[22],"by":[23],"close-coupled":[24,39],"systems":[25],"that":[26,68,105],"provide":[27],"enhanced":[28],"airflow":[29],"and":[30,45,72,88,96,110,122],"capacity.":[32],"This":[33],"work":[34],"presents":[35],"a":[36,66,76,131],"model":[37],"for":[38],"with":[42,83],"free":[43],"cooling,":[44],"explores":[46],"the":[47,59,135],"consumption":[49],"trade-offs":[50],"these":[52],"facilities":[53],"as":[54],"outdoor":[55],"temperature":[56],"changes":[57],"throughout":[58],"year.":[60],"Using":[61],"this":[62],"model,":[63],"we":[64],"propose":[65],"technique":[67,80],"jointly":[69],"allocates":[70],"workload":[71,108],"controls":[73],"power-efficient":[77],"way.":[78],"Our":[79],"tested":[82],"configuration":[84],"parameters,":[85],"traces,":[87],"weather":[89],"collected":[91],"from":[92,100],"real-life":[93],"centers,":[95],"application":[97],"profiles":[98],"obtained":[99],"enterprise":[101],"servers.":[102],"Results":[103],"show":[104],"our":[106],"joint":[107],"allocation":[109],"policy":[112],"provides":[113],"5%":[114],"reduction":[115],"overall":[117],"center":[119],"energy":[120],"consumption,":[121],"up":[123],"to":[124,130],"24%":[125],"peak":[126],"reduction,":[128],"leading":[129],"6%":[132],"decrease":[133],"electricity":[136],"costs":[137],"without":[138],"affecting":[139],"performance.":[140]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
