{"id":"https://openalex.org/W1986690380","doi":"https://doi.org/10.1109/iembs.2011.6091776","title":"High-resolution MREIT using low imaging currents","display_name":"High-resolution MREIT using low imaging currents","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W1986690380","doi":"https://doi.org/10.1109/iembs.2011.6091776","mag":"1986690380","pmid":"https://pubmed.ncbi.nlm.nih.gov/22255956"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6091776","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6091776","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5020584084","display_name":"Eung Je Woo","orcid":"https://orcid.org/0000-0001-5100-6945"},"institutions":[{"id":"https://openalex.org/I35928602","display_name":"Kyung Hee University","ror":"https://ror.org/01zqcg218","country_code":"KR","type":"education","lineage":["https://openalex.org/I35928602"]},{"id":"https://openalex.org/I160888826","display_name":"Kyung Hee Cyber University","ror":"https://ror.org/01bxb0563","country_code":"KR","type":"education","lineage":["https://openalex.org/I160888826"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Eung Je Woo","raw_affiliation_strings":["Department of Biomedical Engineering, Kyung HeeUniversity, Gyeonggi-do 446-701, Korea. ejwoo@ khu.ac.kr","Department of Biomedical Engineering, Kyung Hee University, Gyeonggi-do 446-701, Korea"],"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Kyung HeeUniversity, Gyeonggi-do 446-701, Korea. ejwoo@ khu.ac.kr","institution_ids":["https://openalex.org/I35928602","https://openalex.org/I160888826"]},{"raw_affiliation_string":"Department of Biomedical Engineering, Kyung Hee University, Gyeonggi-do 446-701, Korea","institution_ids":["https://openalex.org/I35928602"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5020584084"],"corresponding_institution_ids":["https://openalex.org/I35928602","https://openalex.org/I160888826"],"apc_list":null,"apc_paid":null,"fwci":0.23648241,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.58650734,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"2011","issue":null,"first_page":"7025","last_page":"7028"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11739","display_name":"Microwave Imaging and Scattering Analysis","score":0.9871000051498413,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9830999970436096,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scanner","display_name":"Scanner","score":0.6081246137619019},{"id":"https://openalex.org/keywords/image-resolution","display_name":"Image resolution","score":0.5521010756492615},{"id":"https://openalex.org/keywords/pixel","display_name":"Pixel","score":0.5499807596206665},{"id":"https://openalex.org/keywords/neuroimaging","display_name":"Neuroimaging","score":0.5045760869979858},{"id":"https://openalex.org/keywords/biomagnetism","display_name":"Biomagnetism","score":0.48141905665397644},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.461535781621933},{"id":"https://openalex.org/keywords/conductivity","display_name":"Conductivity","score":0.45797109603881836},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.41838592290878296},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4023079574108124},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3694579601287842},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.3680087924003601},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.31939974427223206},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.07927912473678589}],"concepts":[{"id":"https://openalex.org/C2779751349","wikidata":"https://www.wikidata.org/wiki/Q1474480","display_name":"Scanner","level":2,"score":0.6081246137619019},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.5521010756492615},{"id":"https://openalex.org/C160633673","wikidata":"https://www.wikidata.org/wiki/Q355198","display_name":"Pixel","level":2,"score":0.5499807596206665},{"id":"https://openalex.org/C58693492","wikidata":"https://www.wikidata.org/wiki/Q551875","display_name":"Neuroimaging","level":2,"score":0.5045760869979858},{"id":"https://openalex.org/C78902741","wikidata":"https://www.wikidata.org/wiki/Q4915071","display_name":"Biomagnetism","level":3,"score":0.48141905665397644},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.461535781621933},{"id":"https://openalex.org/C131540310","wikidata":"https://www.wikidata.org/wiki/Q907564","display_name":"Conductivity","level":2,"score":0.45797109603881836},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.41838592290878296},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4023079574108124},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3694579601287842},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.3680087924003601},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.31939974427223206},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.07927912473678589},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C118552586","wikidata":"https://www.wikidata.org/wiki/Q7867","display_name":"Psychiatry","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001921","descriptor_name":"Brain","qualifier_ui":"Q000473","qualifier_name":"pathology","is_major_topic":false},{"descriptor_ui":"D001931","descriptor_name":"Brain Mapping","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D002645","descriptor_name":"Chickens","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003952","descriptor_name":"Diagnostic Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004553","descriptor_name":"Electric Conductivity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008959","descriptor_name":"Models, Neurological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059906","descriptor_name":"Neuroimaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013552","descriptor_name":"Swine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001921","descriptor_name":"Brain","qualifier_ui":"Q000473","qualifier_name":"pathology","is_major_topic":false},{"descriptor_ui":"D001931","descriptor_name":"Brain Mapping","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D002645","descriptor_name":"Chickens","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003952","descriptor_name":"Diagnostic Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004553","descriptor_name":"Electric Conductivity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008959","descriptor_name":"Models, Neurological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059906","descriptor_name":"Neuroimaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013552","descriptor_name":"Swine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001921","descriptor_name":"Brain","qualifier_ui":"Q000473","qualifier_name":"pathology","is_major_topic":false},{"descriptor_ui":"D001931","descriptor_name":"Brain Mapping","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D002645","descriptor_name":"Chickens","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003952","descriptor_name":"Diagnostic Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004553","descriptor_name":"Electric Conductivity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008959","descriptor_name":"Models, Neurological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059906","descriptor_name":"Neuroimaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013552","descriptor_name":"Swine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/iembs.2011.6091776","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6091776","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22255956","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22255956","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W163155618","https://openalex.org/W801393845","https://openalex.org/W1967654956","https://openalex.org/W2000533021","https://openalex.org/W2022596044","https://openalex.org/W2022981781","https://openalex.org/W2026802103","https://openalex.org/W2048418232","https://openalex.org/W2050971853","https://openalex.org/W2080955914","https://openalex.org/W2084925615","https://openalex.org/W2092645735","https://openalex.org/W2095208172","https://openalex.org/W2097121942","https://openalex.org/W2105914451","https://openalex.org/W2125710254","https://openalex.org/W2138659210","https://openalex.org/W2145527624","https://openalex.org/W2168832646","https://openalex.org/W4299389866","https://openalex.org/W6606538881","https://openalex.org/W6622985382","https://openalex.org/W6657136918"],"related_works":["https://openalex.org/W4232857084","https://openalex.org/W4245233074","https://openalex.org/W2167384162","https://openalex.org/W4366829084","https://openalex.org/W2327340211","https://openalex.org/W1517555227","https://openalex.org/W2027542625","https://openalex.org/W2653993779","https://openalex.org/W2147113764","https://openalex.org/W2120357498"],"abstract_inverted_index":{"Magnetic":[0],"Resonance":[1],"Electrical":[2],"Impedance":[3],"Tomography":[4],"(MREIT)":[5],"produces":[6],"cross-sectional":[7],"images":[8,137],"of":[9,46,69,94,158,165],"a":[10,23,54,111,117,169],"conductivity":[11,43,98,136],"distribution":[12],"inside":[13],"the":[14,66,92,149,163],"human":[15,51],"body.":[16],"We":[17,145],"use":[18],"an":[19],"MRI":[20,114],"scanner":[21,115],"as":[22,168],"tool":[24],"to":[25,34,78,96,147,153,161],"measure":[26],"induced":[27],"internal":[28],"magnetic":[29],"flux":[30],"density":[31],"distributions":[32],"subject":[33],"externally":[35],"injected":[36],"currents.":[37,86,106],"Recent":[38],"experimental":[39,108,151],"MREIT":[40,70,81,95,167],"studies":[41],"demonstrated":[42],"image":[44],"reconstructions":[45],"in":[47,72,134,154],"vivo":[48,155],"animal":[49],"and":[50,122],"subjects":[52],"with":[53,100,116,138],"few":[55],"millimeter":[56],"pixel":[57,143],"size":[58],"using":[59,83,110],"3":[60,112],"mA":[61,104],"current":[62],"injections.":[63],"To":[64],"enhance":[65],"clinical":[67],"applicability":[68],"especially":[71],"neuroimaging":[73],"applications,":[74],"it":[75],"is":[76],"necessary":[77],"develop":[79],"high-resolution":[80],"techniques":[82],"low":[84],"imaging":[85,99,157],"In":[87],"this":[88],"study,":[89],"we":[90,128],"demonstrate":[91,126],"capability":[93],"perform":[97],"less":[101,139],"than":[102,140],"1":[103,141],"injection":[105],"The":[107],"results":[109],"T":[113],"multi-echo":[118],"ICNE":[119],"pulse":[120],"sequence":[121],"high-performance":[123],"RF":[124],"coils":[125],"that":[127],"can":[129],"distinguish":[130],"two":[131],"different":[132],"anomalies":[133],"reconstructed":[135],"mm":[142],"sizes.":[144],"plan":[146],"apply":[148],"developed":[150],"method":[152],"head":[156],"small":[159],"animals":[160],"investigate":[162],"feasibility":[164],"functional":[166],"new":[170],"neuro-imaging":[171],"method.":[172]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
