{"id":"https://openalex.org/W2001299465","doi":"https://doi.org/10.1109/iembs.2011.6091736","title":"A real time, wearable ECG and continous blood pressure monitoring system for first responders","display_name":"A real time, wearable ECG and continous blood pressure monitoring system for first responders","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W2001299465","doi":"https://doi.org/10.1109/iembs.2011.6091736","mag":"2001299465","pmid":"https://pubmed.ncbi.nlm.nih.gov/22255923"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6091736","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6091736","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067137135","display_name":"David Ribeiro","orcid":"https://orcid.org/0000-0003-0001-4456"},"institutions":[{"id":"https://openalex.org/I60858718","display_name":"University of Aveiro","ror":"https://ror.org/00nt41z93","country_code":"PT","type":"education","lineage":["https://openalex.org/I60858718"]}],"countries":["PT"],"is_corresponding":true,"raw_author_name":"D. M. D. Ribeiro","raw_affiliation_strings":["Institute of Electronics and TelematicsEngineering of Aveiro, Aveiro, University of Aveiro, Portugal. davidribeiro@ua.pt","Institute of Electronics and Telematics Engineering of Aveiro (IEETA), Aveiro, University of Aveiro, Portugal"],"affiliations":[{"raw_affiliation_string":"Institute of Electronics and TelematicsEngineering of Aveiro, Aveiro, University of Aveiro, Portugal. davidribeiro@ua.pt","institution_ids":["https://openalex.org/I60858718"]},{"raw_affiliation_string":"Institute of Electronics and Telematics Engineering of Aveiro (IEETA), Aveiro, University of Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004627278","display_name":"M\u00e1rcio Colunas","orcid":"https://orcid.org/0000-0002-8332-8487"},"institutions":[{"id":"https://openalex.org/I60858718","display_name":"University of Aveiro","ror":"https://ror.org/00nt41z93","country_code":"PT","type":"education","lineage":["https://openalex.org/I60858718"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"M. F. M. Colunas","raw_affiliation_strings":["Institute of Electronics and Telematics Engineering of Aveiro (IEETA), University of Aveiro, Portugal","Institute of Electronics and Telematics Engineering of Aveiro (IEETA), Aveiro, University of Aveiro, Portugal"],"affiliations":[{"raw_affiliation_string":"Institute of Electronics and Telematics Engineering of Aveiro (IEETA), University of Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]},{"raw_affiliation_string":"Institute of Electronics and Telematics Engineering of Aveiro (IEETA), Aveiro, University of Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084965021","display_name":"Fabio A. Ferreira Marques","orcid":null},"institutions":[{"id":"https://openalex.org/I60858718","display_name":"University of Aveiro","ror":"https://ror.org/00nt41z93","country_code":"PT","type":"education","lineage":["https://openalex.org/I60858718"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"F. A. F. Marques","raw_affiliation_strings":["Institute of Electronics and Telematics Engineering of Aveiro (IEETA), University of Aveiro, Portugal","Institute of Electronics and Telematics Engineering of Aveiro (IEETA), Aveiro, University of Aveiro, Portugal"],"affiliations":[{"raw_affiliation_string":"Institute of Electronics and Telematics Engineering of Aveiro (IEETA), University of Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]},{"raw_affiliation_string":"Institute of Electronics and Telematics Engineering of Aveiro (IEETA), Aveiro, University of Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061406904","display_name":"Jos\u00e9 Maria Fernandes","orcid":"https://orcid.org/0000-0002-0681-9354"},"institutions":[{"id":"https://openalex.org/I60858718","display_name":"University of Aveiro","ror":"https://ror.org/00nt41z93","country_code":"PT","type":"education","lineage":["https://openalex.org/I60858718"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"J. M. Fernandes","raw_affiliation_strings":["Department of Electronics, Telecommunications and Informatics and IEETA, University of Aveiro, Aveiro, Portugal"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Telecommunications and Informatics and IEETA, University of Aveiro, Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5015159230","display_name":"Jo\u00e3o Paulo Silva Cunha","orcid":"https://orcid.org/0000-0003-4131-9045"},"institutions":[{"id":"https://openalex.org/I60858718","display_name":"University of Aveiro","ror":"https://ror.org/00nt41z93","country_code":"PT","type":"education","lineage":["https://openalex.org/I60858718"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"J. P. S. Cunha","raw_affiliation_strings":["Department of Electronics, Telecommunications and Informatics and IEETA, University of Aveiro, Aveiro, Portugal"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Telecommunications and Informatics and IEETA, University of Aveiro, Aveiro, Portugal","institution_ids":["https://openalex.org/I60858718"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5067137135"],"corresponding_institution_ids":["https://openalex.org/I60858718"],"apc_list":null,"apc_paid":null,"fwci":0.5765,"has_fulltext":false,"cited_by_count":20,"citation_normalized_percentile":{"value":0.71651034,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"17","issue":null,"first_page":"6894","last_page":"6898"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.7292844653129578},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.6944645643234253},{"id":"https://openalex.org/keywords/wearable-technology","display_name":"Wearable technology","score":0.5419321060180664},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.535659670829773},{"id":"https://openalex.org/keywords/certification","display_name":"Certification","score":0.5037798285484314},{"id":"https://openalex.org/keywords/pulse-rate","display_name":"Pulse rate","score":0.47281041741371155},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4460354149341583},{"id":"https://openalex.org/keywords/vital-signs","display_name":"Vital signs","score":0.4231640100479126},{"id":"https://openalex.org/keywords/stress","display_name":"Stress (linguistics)","score":0.41397497057914734},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.4064503312110901},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35561537742614746},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.2326120138168335},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.18705621361732483},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.08361703157424927}],"concepts":[{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.7292844653129578},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.6944645643234253},{"id":"https://openalex.org/C54290928","wikidata":"https://www.wikidata.org/wiki/Q4845080","display_name":"Wearable technology","level":3,"score":0.5419321060180664},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.535659670829773},{"id":"https://openalex.org/C46304622","wikidata":"https://www.wikidata.org/wiki/Q374814","display_name":"Certification","level":2,"score":0.5037798285484314},{"id":"https://openalex.org/C2988351347","wikidata":"https://www.wikidata.org/wiki/Q191733","display_name":"Pulse rate","level":3,"score":0.47281041741371155},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4460354149341583},{"id":"https://openalex.org/C2776890885","wikidata":"https://www.wikidata.org/wiki/Q1067560","display_name":"Vital signs","level":2,"score":0.4231640100479126},{"id":"https://openalex.org/C21036866","wikidata":"https://www.wikidata.org/wiki/Q181767","display_name":"Stress (linguistics)","level":2,"score":0.41397497057914734},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.4064503312110901},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35561537742614746},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.2326120138168335},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.18705621361732483},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.08361703157424927},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D003020","descriptor_name":"Clothing","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003020","descriptor_name":"Clothing","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003020","descriptor_name":"Clothing","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013997","descriptor_name":"Time Factors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013997","descriptor_name":"Time Factors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013997","descriptor_name":"Time Factors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015924","descriptor_name":"Blood Pressure Monitors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015924","descriptor_name":"Blood Pressure Monitors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015924","descriptor_name":"Blood Pressure Monitors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D060731","descriptor_name":"Emergency Responders","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D060731","descriptor_name":"Emergency Responders","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D060731","descriptor_name":"Emergency Responders","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/iembs.2011.6091736","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6091736","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22255923","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22255923","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.800000011920929}],"awards":[],"funders":[{"id":"https://openalex.org/F4320334779","display_name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","ror":"https://ror.org/00snfqn58"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1976413817","https://openalex.org/W2005213254","https://openalex.org/W2007461469","https://openalex.org/W2020410802","https://openalex.org/W2026699230","https://openalex.org/W2054421446","https://openalex.org/W2064301857","https://openalex.org/W2065105236","https://openalex.org/W2067731110","https://openalex.org/W2071447853","https://openalex.org/W2094265147","https://openalex.org/W2121478090","https://openalex.org/W2124277610","https://openalex.org/W2124909584","https://openalex.org/W2154126140","https://openalex.org/W2160439670","https://openalex.org/W2165065515","https://openalex.org/W2167925220"],"related_works":["https://openalex.org/W3090300519","https://openalex.org/W2514492205","https://openalex.org/W4250401876","https://openalex.org/W2943851981","https://openalex.org/W2566526749","https://openalex.org/W2907667791","https://openalex.org/W3047461507","https://openalex.org/W3126390843","https://openalex.org/W4245880644","https://openalex.org/W4312415459"],"abstract_inverted_index":{"The":[0,67],"study":[1,35],"of":[2,30,49],"stress":[3,36,93],"and":[4,24,37,53,81,94],"fatigue":[5,25,95],"among":[6,96],"First":[7],"Responders":[8],"is":[9,69,82],"a":[10,44,61,86],"major":[11],"step":[12],"in":[13,57,91],"mitigating":[14],"this":[15,40],"public":[16],"health":[17],"problem.":[18],"Blood":[19],"pressure,":[20],"heart":[21],"rate":[22],"variability":[23],"related":[26],"arrhythmia":[27],"are":[28],"three":[29],"the":[31],"main":[32],"\"windows\"":[33],"to":[34,84,88],"fatigue.":[38],"In":[39],"paper":[41],"we":[42],"present":[43],"wearable":[45,75],"medical":[46,76],"device,":[47],"capable":[48],"acquiring":[50],"an":[51,72],"electrocardiogram":[52],"estimating":[54],"blood":[55],"pressure":[56],"real":[58],"time,":[59],"through":[60],"pulse":[62],"wave":[63],"transit":[64],"time":[65],"approach.":[66],"system":[68],"based":[70],"on":[71],"existent":[73],"certified":[74],"device":[77],"called":[78],"\"Vital":[79],"Jacket\"":[80],"aimed":[83],"become":[85],"tool":[87],"allow":[89],"cardiologists":[90],"studying":[92],"first":[97],"response":[98],"professionals.":[99]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":2}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
